Laserfiche WebLink
UNIT 6 <br />ELECTRICAL PLAN <br />1 /4" = 1'-0" <br />ELECTRICAL SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />— — — <br />INDICATES SWITCH LEG CIRCUITING <br />DUPLEX RECEPTACLE <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER 0 42' A.F.F. <br />220V RECEPTACLE <br />�GA <br />GROUND FAULT INTERRUPT RECEPTACLE <br />wP <br />WEATHER PROOF DUPLEX RECEPTACLE <br />® <br />SPECIAL PURPOSE OUTLET <br />SURFACE MOUNTED INCANDESCENT LIGHT <br />SURFACE MOUNTED INCANDESCENT STRIP LIGHTING <br />— <br />FLORESCENT STRIP LIGHTING <br />0 <br />CEILING MOUNTED INCANDESCENT LIGHT <br />CEILING RECESSED MOUNTED INCANDESCENT LIGHT <br />TO <br />oDB <br />SINGLE PUSH BUTTON DO = DOOR CHIME, GO = GARAGE DOOR <br />$ <br />SINGLE POLE SWITCH <br />$3 <br />3—WAY SWITCH <br />SECURITY FLOOD LIGHT <br />0 <br />EXHAUST FAN <br />® <br />CHIME <br />ELECTRICAL PANEL BOARD <br />N� <br />TELEVISION JACK <br />WALL TELEPHONE <br />DISCONNECT <br />�T <br />THERMOSTAT <br />SD <br />SMOKE DETECTOR <br />SMOKE DETECTOR/CARBON MONOXIDE DETECTOR <br />CEILING FAN /W LIGHT <br />(DASHED INDICATE PREWIRED FOR <br />CEILING FAN/LIGHT ON TWO SWITCHES <br />BRACED FOR CEILING FAN/LIGHT) <br />UNIT 5 <br />METER CAN BY O <br />ELECTRIC UTILITY CO. — <br />TO UNDERGROUND <br />SERVICE BY ELECTRIC <br />UTILITY CO. <br />150 <br />N.T.S. <br />150 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL—, <br />AMP <br />2" C WITH 3-4�/0 THW AL <br />#4 CU. GROUNuu <br />TO COLD WATER LINE <br />5/8" X 8" GROUND LINE <br />(ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />AMP ELECTRICAL RISER <br />UNIT 4 <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, ALL APPLICABLE LOCAL ORDINANCES <br />AND IN COOPERATION WITH THE UMM COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT AIL OUTLETS AND RECEPTACLES PLUMB AND FLUSH <br />WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN <br />OTHERWISE. <br />5. INSTALL ELBCTRICAL CABLE, WIRE AND CONNECTORS AS <br />INDICATED IN ACCORDANCE WITH THE MANUFACURERS WRITTEN <br />INSTRUCTION, THE APPLICABLE REQUIREMENTS OF NEC AND THE <br />NATIONAL ELECTRIC CONTRACTORS ASSOCIATION "STANDARD OF <br />INSTALLATION" AND IN ACCORDANCE WITH RECOGNMED INDUSTRY <br />PRACTICES TO ENSURE THAT PRODUCTION SERVE THE INTENDED <br />FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR <br />NM CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELBCTRICAL REQUIREMMM FOR A/C WITH A/C <br />CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CURCUIT IIVTERRUI'T'ER) PROTECTED CIRCUIT. <br />9. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS TO BE HARD WIRED. <br />10. ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC —FAULT AFh <br />11. PROVIDE MINIMUM 75% HIGH EFFICTENCY LIGHTING. <br />(FBGENERGY CONSERVATION R404) <br />12. REFERENCE SECTION 39, POWER & LIORTINO DISTRIBUTION.. <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-10, & FBC 2017 <br />(6TH. EDITION). <br />u � <br />o � <br />STA" �y <br />a <br />4® SUP <br />0 <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSE NUMBER: 53608 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 11-15-18 <br />101 ItT 1,1i z11-3i4111 p :A III <br />DATE: <br />LT11R? <br />RO 4 <br />PROTECT ADDRESS: <br />BUTTERFIELD INVESTMENTS, INC. <br />COURT ST. <br />ZEPHYRHILLS, FL. 33542 <br />CONTRACTOR: <br />JOEL BAILEY <br />TRI-PLEX PLAN <br />ELECTRICAL PLAN <br />DWG. WB-14 REV. 0 <br />