My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38021 10th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38021 10th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:35:36 PM
Creation date
2/19/2025 8:50:11 AM
Metadata
Fields
Template:
Building Plans
Street #
38021
Location
10th Ave
Contractor
Butterfield Investment
Building Plans - Permit #
21912
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL PLAN <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE <br />LOCATED WITH -IN 10' OF EACH BEDROOM <br />\10. PROVIDE MINIMUM 75% HIGH -EFFICIENCY LIGHTING. (FBC-ENERGY CONSERVATION R404) <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL <br />METER CAN BY <br />ELECTRIC UTILITY CO.- AMP <br />L 2" C WITH 3-4 0 THW AL <br />TO UNDERGROUND #4 CU. GROUN� <br />SERVICE BY ELECTRIC <br />UTILITY CO. <br />TO COLD WATER LINE <br />5 8" X 8" GROUND LINE <br />( ASCO CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />� EX. 200 AMP ELECTRICAL RISER <br />N.T.S. <br />100 AMP MAIN BREAKER <br />20 CIRCUIT SURFACE MOUNT <br />PANEL <br />#4 SER CU. <br />OR <br />100 #2 SER ALUMN. <br />AMP <br />BEDROOM EMERGENCY EGRESS SHALL BE DIRECTLY TO ❑UTSIDE <br />EGRESS WIND❑WS SHALL BE SIZED, LOCATED AND INSTALLED PER FBC 2017 <br />ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC -FAULT <br />ARC FAULT PROTECTED OUTLETS SHALL BE <br />INSTALLED PER NEC 210,12(B), <br />GFI PROTECTED CIRCUITS SHALL BE INSTALLED IN GARAGE ADDITI❑NS, <br />BATHROOMS & KITCHENS, LAUNDRY ROOMS AND OUTSIDE RECEPTACLE <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-10, & FBC 2017 <br />(6TH. EDITION). <br />G r <br />'/ 9ii0 iPX <br />11 %���� <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSB NUMBER: 53608 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 09-03-19 <br />DRAWN BY: L.E.D. <br />REVISION: <br />R01 <br />RO 2 <br />RO 3 <br />a�' <br />r1j*4 <br />PROTECT ADDRESS: <br />3802110TH. AVE. <br />ZEPHYRHILLS, FL. 33542 <br />CONTRACTOR: <br />BUTTERFIELD INVESTMENTS <br />HOUSE PLAN <br />ELECTRICAL PLAN <br />1 /4"4-0" <br />DWG.38021-A6 REV.O <br />
The URL can be used to link to this page
Your browser does not support the video tag.