My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38550 13th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38550 13th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:42:29 PM
Creation date
2/19/2025 8:50:22 AM
Metadata
Fields
Template:
Building Plans
Street #
38550
Location
13th Ave
Contractor
Butterfield Investments
Building Plans - Permit #
1656
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GFl <br />■ 1-_— <br />MASTER BATH <br />AFC <br />■ <br />HB , <br />WP I W.I.C. <br />L----------------� <br />2868 <br />■ <br />AFC <br />MASTER SUITE <br />'If GFI 1 2868 <br />C <br />UTILITY ROOM-- — <br />L�1 DRYER <br />U WASHER <br />WA/C s cE <br />.�-- <br />GFI BEARING WALL <br />\\\ F �ATTIC ACCESS I I I <br />\ C 22x54 I I <br />■ \ L_ — j <br />GA <br />I <br />i <br />i <br />■ I <br />GARAGE <br />I <br />I <br />I <br />I <br />� 11 <br />r------------------------------------------i <br />1 � <br />11 <br />■ I 11 <br />l <br />11 <br />V <br />I <br />I I\ <br />16070 \ <br />■ ■ kL. <br />co <br />PATI❑ <br />■�—'I■ ■I' 4■I ■ <br />FOYER <br />i <br />P� <br />ELECTRICAL PLAN <br />1 /4"=1'-0" <br />35 SH <br />EGRESS <br />■ <br />■ <br />GFI DINING ROOM <br />■ <br />a___ <br />GFl GFl GFl <br />KITCHEN I �— ■ <br />REF. — J GA <br />Ir---- — — ---- <br />I i � <br />! PANTRY <br />i <br />AFC 0 \\ � l <br />AFC <br />U <br />BEDROOM #3 <br />AFC <br />35 SH III <br />EGRESS <br />PORCH <br />BATH #2 <br />��l ------------- <br />SDi0, <br />I� <br />'? AFFCCc <br />AFC U <br />BEDROOM #2 <br />AFC db <br />35 SH <br />EGRESS <br />■ <br />■ <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL <br />METER CAN BY <br />ELECTRIC UTILITY CO. O AMP <br />L2* C WITH 3-4 0 THW AL <br />TO UNDERGROUND #4 CU. GROUN <br />SERVICE BY ELECTRIC <br />UTILITY CO. <br />TO COLD WATER LINE <br />5/8' X 8° GROUND LINE <br />(PASCO CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />A EX. 200 AMP ELECTRICAL RISER <br />100 AMP MAIN BREAKER <br />20 CIRCUIT SURFACE MOUNT <br />PANEL <br />#4 SER CU. <br />OR <br />#2 SER ALUMN. <br />ELECTRICAL SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />— — — <br />INDICATES SWITCH LEG CIRCUITING <br />DUPLEX RECEPTACLE <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER 0 42" A.F.F. <br />220V RECEPTACLE <br />GFI <br />GROUND FAULT INTERRUPT RECEPTACLE <br />WP <br />WEATHER PROOF DUPLEX RECEPTACLE <br />® <br />SPECIAL PURPOSE OUTLET <br />SURFACE MOUNTED INCANDESCENT LIGHT <br />-0- <br />SURFACE MOUNTED INCANDESCENT STRIP LIGHTING <br />FLORESCENT STRIP LIGHTING <br />-�- <br />CEILING MOUNTED INCANDESCENT LIGHT <br />0 <br />CEILING RECESSED MOUNTED INCANDESCENT LIGHT <br />;DB <br />SINGLE PUSH BUTTON DB = DOOR CHIME, GD = GARAGE DOOR <br />$ <br />SINGLE POLE SWITCH <br />$3 <br />3-WAY SWITCH <br />SECURITY FLOOD LIGHT <br />0 <br />EXHAUST FAN <br />® <br />CHIME <br />o <br />ELECTRICAL PANEL BOARD <br />TV <br />TELEVISION JACK <br />WALL TELEPHONE <br />E5 <br />DISCONNECT <br />0 <br />THERMOSTAT <br />SD <br />SMOKE DETECTOR <br />SMOKE DETECTOR/CARBON MONOXIDE DETECTOR COMBINATION <br />CEILING FAN /W LIGHT <br />DASHED INDICATE PREWIRED FOR <br />CEILING FAN LIGHT ON TWO SWITCHES i i _J <br />BRACED FO CEILING FAN/LIGHT) <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE <br />LOCATED WITH —IN 10' OF EACH BEDROOM <br />10. PROVIDE MINIMUM 75% HIGH —EFFICIENCY LIGHTING. (FBC—ENERGY CONSERVATION R404) <br />BEDROOM EMERGENCY EGRESS SHALL BE DIRECTLY TO OUTSIDE <br />EGRESS WINDOWS SHALL BE SIZED, LOCATED AND INSTALLED PER FBC 2017 <br />ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC —FAULT <br />ARC FAULT PROTECTED OUTLETS SHALL BE <br />INSTALLED PER NEC 210.12(B). <br />GFI PROTECTED CIRCUITS SHAM BE INSTALLED IN GARAGE ADDITIONS, <br />BATHROOMS &KITCHENS, LAUNDRY ROOMS AND OUTSIDE RECEPTACLES <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-16, & FBC 2020 <br />(7tb. EDITION). <br />PROFESSIONAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSE NUMBER 53608 <br />9909 Wallaston Drive <br />Dade City, FL 33525 <br />Ph. 813-469-2289 <br />Email: <br />l- <br />dmBpegOgmalcom <br />RI � <br />•...c. A.�• • V �s® /4 <br />: o. 53 08 <br />jj <br />_sty <br />-� ? ATE l r <br />��. .w <br />NA 1. <br />Plans By <br />Larry deMontmollin <br />90 Country Club Lace <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 02-15-21 <br />DRAWN BY: L.E.D. <br />REVISION: DATE: <br />RO 1 <br />RO 2 <br />RO 3 <br />RO 4 <br />PROJECT ADDRESS: <br />3855013dh. ST, <br />Zephyrhills, Florida 33542 <br />CONTRACTOR: <br />BUITERFIBLD INVSSTMBNTS. LLC. I <br />HOUSE PLAN <br />ELECTRICAL PLAN <br />N.T.S. <br />DWG. BF-50-A6 REV. 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.