Laserfiche WebLink
. <br />ENGINEER'S NOTES <br />ALL WORK TO BE DONE ACC❑RDING TO FLORIDA BUILDING CODES, <br />BUILDINGS OR STRUCTURES SHALL CONFORM TO <br />2020 FBC 7th, EDITI❑N BUILDING. <br />AN ADDITI❑N TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS <br />FOR NEW C❑NSTRUCTI❑N WITH❑UT REQUIRING THE EXISTING BUILDING OR STRUCTURE <br />TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PR❑VISI❑NS <br />EXCEPT AS REQUIRED BY CHAPTER 10, WHERE AN ADDITI❑N IMPACTS THE EXISTING <br />BUILDING OR STRUCTURE, THAT P❑RTI❑N SHALL COMPLY WITH THIS CODE, <br />CREATI❑N OR EXTENSI❑N OF N❑NC❑NF❑RMITY. AN ADDITI❑N SHALL NOT CREATE OR <br />EXTEND ANY N❑NC❑NF❑RMITY IN THE EXISTING BUILDING TO WHICH THE ADDITI❑N IS <br />BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, <br />MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL <br />SYSTEMS, <br />ASSUMED S❑IL BEARING CAPACITY TO BE 2000 PSF. S❑IL CAPACITY TO BE VERIFIED <br />BY CONTRACTOR PRI❑R TO C❑NSTRUCTI❑N, INF❑RM ENGINEER OF VARIATI❑NS. <br />F❑❑TINGS TO BE EXCAVATED TO CLEAN S❑IL, FREE OF VEGETATI❑N AND <br />DELETERI❑US MATTER. CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE. <br />CONCRETE ; <br />MINIMUM C❑MPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS, ALL <br />CONCRETE SHALL BE 'READY MIXED' AND IN ACCORDANCE WITH A.S.T.M. <br />SPECIFICATI❑N C-94. <br />SLAB ON FILL ; <br />INTERI❑R CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF <br />MEMBRANES, ALL SLABS TO BE REINF❑RCED WITH 6X6 10/10 WELDED WIRE MESH. <br />LUMBER ; <br />1, STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED, <br />2, CURRENT EDITI❑N, ASS❑CIATI❑N GRADING RULES GOVERN. <br />3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY. <br />4. ANY SPECIES ALLOWED UNLESS ❑THERWISE NOTED, <br />5. SIZES ARE N❑MINAL. ACTUAL SIZES SHALL CONFORM TO AMERICAN <br />LUMBER STANDARD PS 20-70. <br />6. M❑ISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE <br />19% OR LESS AT THE TIME OF INSTALLATI❑N, <br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO <br />AMERICAN INSTITUTE OF TIMBER C❑NSTRUCTI❑N (AITC) SPECIFICATI❑NS, ALL <br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED, <br />TERMITE TREATING ; <br />S❑IL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0" <br />BEYOND THE PERIMETER LINES OF THE BUILDING, <br />ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3' AGAINST <br />S❑IL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR, <br />HEADERS SHALL BE DBL. 2X MEMBERS AND LAMINATED W/1/2' PLYWOOD <br />GLUED W/C❑NSTRUCTI❑N ADHESIVE AND NAILED W/#16D COMMONS 16' D.C. <br />ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS. <br />CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATI❑NS (CUT SHEETS) ON SITE <br />AT THE TIME OF INSPECTI❑N, FOR REVIEW BY THE BUILDING INSPECT❑R, <br />TO MEET LOADS AS INDICATED. <br />DOORS & WIND❑WS <br />ENGINEERS NOTES: <br />DESIGN L❑ADSi <br />A. WIND LOADS, PER; <br />1) RISK CATEGORY 11 - PER (TABLE 1604,5/TABLE 1.5-1) <br />2) EXP, 'B', PER TABLE 1609.4.5/SECTI❑N 26,7.5 <br />3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 140 MPH ult 3 SEC GUST <br />4) N❑MINAL DESIGN WIND SPEED, V (ASD) = 108 MPH asd 3 SEC GUST <br />5) INTERNAL PRESSURE C❑❑FFICIENT, GCPI = .18 ENCLOSED PER TABLE 26.11.1 <br />6) COMP. & CLADDING PRESSURES PER TABLE R301.2(2), UNLESS SPECIFICALLY LABELED ON PLAN <br />B. LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED T❑; <br />1) ROOF LIVE LOAD = 20 PSF <br />2) FLOOR LIVE LOAD = 40 PSF <br />3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF <br />4) HABITTABLE ATTIC LIVE LOAD = 20 PSF <br />C, DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED TO: <br />1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF <br />2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF <br />3) FLOOR DEAD LOAD = 20 PSF <br />APPLICABLE CODES: <br />7th. EDITI❑N, 2020 FLORIDA BUILDING CODE, BUILDING. PLUMBING, <br />MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING <br />DATA SUMMARY1 <br />BUILDING USE1 RESIDENCE GROUP WITH MORE THAN TWO DWELLING UNITS, TYPE R2. <br />C❑NSTRUCTI❑N TYPE V, UNPROTECTED, UNSPRINKLED <br />Residential Group R-2 occupancies containing sleeping units or more than two dwelling <br />units where the occupants are primarily permanent In nature. <br />ALL BEDROOMS REQUIRE AN ❑UTSIDE WIND❑W OR DOOR OPERABLE FROM INSIDE WITH❑UT THE <br />USE OF TOOLS AND PR❑VIDING A CLEAR ❑PENING OF NOT LESS THAN 20" WIDTH, 24' IN HEIGHT <br />& 5,7 SQ, FT. IN AREA. THE BOTTOM OF THE ❑PENING SHALL NOT BE MORE THAN 44' OFF THE <br />FLOOR AND NO PART OF THE ❑PERATING MECHANISM SHALL BE PLACED HIGHER THAN 54' A.F.F. <br />WIND❑WS GREATER THAN 72' ABOVE 72' FINISHED GRADE SHALL HAVE THW WIND❑W SILL HEIGHT <br />GREATER THAN 24' OR PR❑VIDE AN FALL PREVENTIVE DEVICE PER R616.2. <br />DOORS & WIND❑WS <br />THE ❑PERATING MECHANISM FOR SINGLE HUNG WIND❑WS SHALL BE AT OR NEAR THE SILL, <br />WIND❑WS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM To THE BLDG, <br />CODE W/ RESPECT TO MIN, EMERGENCY EGRESS REQUIREMENTS PER N.F.P.A. 101 CHAPTER 24, <br />ALL GLASS WITHIN 24" OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND <br />SHOWER ENCLOSURES AND WIND❑WS WITHIN LESS THAN 60' AV❑VE STAIR LANDINGS OR TREADS SHALL BE <br />TEMPERED SAFETY GLASS, SEE ADDITI❑NAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308, <br />SINGLE SWING EXTERI❑R DOORS C❑NNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH <br />S❑LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, S❑LID OR HONEYCOMB CORE <br />STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED DOORS, <br />WHERE MASONRY ❑PENINGS REQUIRE WOOD FRAMING, TO FIT WIND❑W OR DOOR SIZES, PRESSURE <br />TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA. x 3 1/2' TAPC❑N SCREWS, 6' <br />FROM EACH END AND 12' C/C, ADDITI❑NAL FRAMING MEMBERS SHALL BE NAILED TO PRI❑R STUD W/ <br />(2) ROWS OF 2d NAILS AT 10' C/C. <br />GYPSUM WALLBOARD <br />PR❑VIDE 1/2' NO SAG GYP. BOARD ON ALL CEILINGS. PR❑VIDE 5/8' TYPE 'X' GYP. BP❑ARD ON ALL <br />GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE. GARAGE SHALL BE SEPARATED FROM THE <br />RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP, BOARD APPLIED TO THE GARAGE SIDE. <br />HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB L❑CATI❑NS, UP TO 8' A.F.F. <br />N❑N-BEARING INTERI❑R PARTITI❑NS <br />ALL INTERI❑R NON BEARING PARTITI❑NS SHALL BE 2X4 SPF @ 16' ❑,C. MAX. SPACING WITH SINGLE TOP <br />AND BOTTOM PLATE W/ 1/2' GYP, DRYWALL EACH SIDE, <br />REQUIRED ATTIC VENTILATION <br />AREA OF ATTIC <br />2154 <br />NET FREE VENTILATION AREA REQ'D. <br />1/300 <br />REQ'D. VENTILATION ATTIC <br />2154/300 <br />7.18 <br />VENTILATION AREA x SQ. INCHES PER FOOT (144) <br />1034.0 <br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC <br />517 <br />OFF RIDGE VENTILATION AREA 115 SQ. INCH PER VENT <br />517/115 <br />TOTAL # OF VENTS REQUIRED <br />4.5 <br />TOTAL # OF VENTS PROVIDED <br />5 <br />SOFFIT VENTILATION AREA 11.736 <br />SQ, INCH PER PER L.F. <br />517/11.736 <br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED <br />44.05 <br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE <br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS <br />INCLUDED) <br />FLORIDA APPROVED PRODUCTS LIST <br />j Parent Approval <br />Manufacturer <br />Category <br />Subcategory <br />App/Seq # <br />Product Model # or Name <br />Model Description <br />FL15220.6 <br />Plastico, Inc. <br />Exterior Doors <br />Swinging Ext. Door <br />Opaque Fiberglass Door <br />Entry Door <br />FL15220.5 <br />FL15279-R5 <br />Plastico, Inc. <br />Clopay Building Products Company <br />Exterior Doors <br />Exterior Doors <br />Windows <br />Swinging Ext. Door Assemblies <br />Sectional Ext. Door Assemblies <br />Single -Hung <br />Opaque Fiberglass Door <br />V1 Series/70 Series <br />Glazed Fiberglass Door <br />Vinyl <br />FL19715 <br />Silverlme Bldg. Products <br />FL6067-R7 <br />Silverline Bldg. Products <br />Windows <br />Mullion <br />{{' <br />Aluminum <br />FL16626-1-R3 <br />FL16305.1-R3 <br />Tamko Building Products <br />Tamko Building Products <br />Roofing <br />Roofing <br />Underlayments <br />Asphalt Shingles <br />TW Underlayment <br />Fiberglass Reinforced <br />FL13192.2 <br />James Hardie <br />Panel Walls <br />Siding <br />HardiePlank <br />Ir FL13223.2 <br />James Hardie <br />Panel Walls <br />Siding <br />HardiePanel <br />FL15272 <br />_ _ <br />Alside <br />Panel Walls <br />Soffits _ <br />- <br />Aluminum - <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />HETA <br />Embedded Truss Anchor <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />META <br />Embedded Truss Anchor <br />- <br />FL10456.2 R4 <br />Simpson Strong -Tie Co. <br />- <br />Structural -Components <br />Wood Connectors Anchors <br />-- --- <br />H2.5 <br />-------- <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />SP1 <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />SP2 <br />_ <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />LSTA12 <br />Strap Ties <br />FL10655.11 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />HUSC <br />Hangers <br />Beam Han g _ <br />FL13904.6 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />MBHA <br />Beam Hangers <br />NOTE 22t-y- FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS. <br />FBCR 2020 - COMPONENTS AND CLADDING - EXP. 'B' PER FBCR R301.2 <br />140 ULt - <br />DESIGN WIND <br />PRESSURE FOR WALLS, DOORS & WIND❑WS <br />(N❑MINAL) <br />COMPONENT <br />ZONE <br />EFFECTIVE WIND AREA <br />WALL <br />10 SQ. FT. <br />20 SQ, <br />FT. <br />50 SQ, FT. <br />100 SQ. FT, <br />WALL <br />O <br />+21.2 PSF / -22.9 PSF <br />+20.2 PSF / <br />-22,0 PSF <br />+19,0 PSF / -20.7 PSF <br />+18.0 <br />PSF / -19.8 PSF <br />WALL <br />n <br />+212 PSF / -28.3 PSF <br />+20.2 PSF / <br />-26.4 PSF <br />+19,0 PSF / -23,9 PSF <br />+18,0 <br />PSF / -22.0 PSF <br />AREA CALCULATIONS: <br />1567 SF - LIVING AREA <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />500 SQ. FT. COMPLIANCE WITH ASCE 7-16, & FBC 2020 <br />+15.8 PSF / -17,6 PSF r7aL ME1 ON). <br />+15.8 PSF / -17.6 PSF ` W. Li <br />NOTE, <br />ALL EXTERI❑R DOORS & WIND❑WS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2020. ALL C❑NNECTIONS TO BUILDING STRUCTURE <br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE. <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 5. <br />2020 FBCR TABLE R301,2 <br />COMPONENTS AND CLADDING - EXP. 'B' <br />140 ULt - ROOF NET UPLIFT SCHEDULE <br />MAIN ROOF (NOMINAL) <br />ROOF <br />ZONE <br />EFFECTIVE WIND AREA <br />DEGREES <br />10 SQ, FT. <br />20 SQ. FT. <br />50 SQ. FT, <br />100 SQ. FT. <br />> 20 TO 27 <br />O <br />+15.8/-28.3 PSF <br />+13.6/-25.1 PSF <br />+10.8/-20.8 PSF <br />+10.0/-17.6 PSF <br />> 20 TO 27 <br />0 O <br />+15.8/-39.1 PSF <br />+13,6/-34.9 PSF <br />+10,8/-29,4 PSF <br />+10.0/-25.3 PSF <br />NOTE, <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE, <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3. <br />2020 FBCR TABLE R301.2 <br />COMPONENTS AND CLADDING - EXP. 'B' <br />140 Ult - ROOF NET UPLIFT SCHEDULE <br />MAIN ROOF (NOMINAL) <br />ROOF <br />ZONE <br />EFFECTIVE WIND AREA <br />DEGREES <br />10 SQ, FT, <br />20 SQ, FT, <br />50 SQ. FT, <br />100 SQ. FT. <br />> 27 TO 45 <br />O <br />+15.1/-30.1 PSF <br />+131/-26.7 PSF <br />+10.5/-22.2 PSF <br />+10.0/-18.8 PSF <br />> 27 TO 45 <br />2� <br />+15.1/-35.9 PSF <br />+13.1/-29.3 PSF <br />+10.5/-176 PSF <br />+10.0/-17.6 PSF <br />> 27 TO 45 <br />2 <br />+15.1/-45.4 PSF <br />+13.1/-38.1 PSF <br />+10.5/-28.4 PSF <br />+10.0/-21.2 PSF <br />> 27 TO 45 <br />3 <br />+15.1/-48.4 PSF <br />+13,1/-36.4 PSF <br />+10.5/-21.2 PSF <br />+10.0/-21.2 PSF <br />503 SF - GARAGE AREA <br />84 SF - PORCH AREA <br />2154 <br />SF - <br />UNDER <br />ROOF <br />128 <br />SF <br />- LANAI <br />AREA <br />NOTEi <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE. <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3. <br />ROOF PITCH 6 ON 12 <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICBNSB NUMBER: 53608 <br />9909 Wallaston Drive <br />Dade City, FL 33525 <br />Ph. 813-469-2289 <br />Email: dws fteg ftmalcom <br />��NA4 11lfi rs <br />��,' N E L. 7-0 <br />e <br />,.�•$�� ENSoe <br />„.° r <br />No. ? <br />06 ... <br />' ST <br />e� , -. 4 0 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />ALL tlVORK SHALL COMPLY WITH PREVAILING <br />t'�" ES EL0R!0 \ BUILDING CODE, <br />ICODES - <br />INA ZONAL ELECTRIC CODE, <br />AND THE CIT`�' CF ZEPHYI1HILL8 <br />ORDINANCES <br />REVIEW DATE - <br />CITY OF ZEPF YRHI <br />PLAN EXAMINER <br />DRAWING PAGE INDEX <br />BE-52-Al - <br />ENGINEERING <br />NOTES <br />BE-52-A2 - <br />FLOOR PLAN <br />BE-52-A3 - <br />ELEVATIONS <br />BE-52-A4 - <br />FOUNDATION <br />PLAN <br />BE-52-A5 <br />- ROOF PLAN <br />BE-52-A6 - <br />ELECTRICAL <br />PLAN <br />BF-S1 - WALL SECTON <br />& DETAILS <br />BE-S2 - <br />SECTIONS & DETAILS <br />BE-S3 <br />- <br />ROOF <br />NAILING <br />& <br />BRACING <br />DATE: 02-15-21 <br />DRAWN BY: L.E.D. <br />REVISION: I DATE: <br />R01 <br />RO 2 <br />RO 3 <br />RO 4 <br />PROJECT ADDRESS: <br />38552 . � �ffo'e- <br />Zephyrhills, Florida 33542 <br />CONTRACTOR: <br />BUITERFIELD INVESTMENTS, LLC. <br />HOUSE PLAN <br />ENGINEERING NOTES <br />DWG® BF-52-Al REV. 0 <br />