Laserfiche WebLink
DOOR v HARDWARE 604EDLILE <br />NO. <br />SIZE <br />TYPE <br />MATERIAL <br />FRAME <br />HDWE <br />FINISH <br />REMARKS <br />109 <br />3' -0" X 7' -0" X 1 3/4" <br />A <br />WOOD <br />I <br />I <br />STAIN <br />REUSE SALVAGED DOOR <br />HARDWARE LEGEND <br />HARDWARE SET #1 <br />PASSAGE SET <br />1 1/2 PAIR BUTT HINGES <br />DOOR STOP, FLOOR MOUNTED <br />SILENCERS (3 PER FRAME MIN.) <br />DOOR TYPES FRAME TYPES <br />SCHD. DIM. <br />N <br />O <br />O <br />U) <br />U) <br />Lu <br />0 <br />0 <br />0 <br />0 <br />Lu <br />U <br />co <br />A I <br />SOLID CORE HOLLOW METAL <br />WOOD <br />FINISH SCHEDULE <br />RM NO. <br />ROOM NAME <br />FLOOR <br />RASE <br />WALLS <br />CLG <br />REMARKS <br />NORTH <br />EAST <br />SOUTH <br />WEST <br />TYPE <br />HT <br />101 <br />ENTRY <br />VCT-I <br />B-I <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />102 <br />OFFICE <br />LVT-I <br />B-I <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />103 <br />BREAK ROOM <br />LVT-1 <br />B-I <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />104 <br />OFFICE <br />LVT-1 <br />B-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />105 <br />OPEN WORK AREA <br />LVT-1 <br />B-I <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />CONVERT TO 2X2 CEILING GRID <br />106 <br />OFFICE <br />LVT-1 <br />B-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />107 <br />OFFICE <br />LVT-1 <br />B-I <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />108 <br />SUPPLY <br />LVT-1 <br />B-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />-- <br />109 <br />WORK AREA <br />LVT-1 <br />13-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />C-1 <br />EXIST <br />FIN15" FLOOR PLAN <br />SCALE: 1/16" = 1'-0" <br />DOOR AND 14AIZDWAIZE NOTES <br />I. ALL NEW DOORS SHALL BE STAIN GRADE FLUSH WOOD <br />DOORS W/ HOLLOW METAL FRAMES TO MATCH BUILDING <br />STANDARD. <br />2. ALL NEW HARDWARE SHALL BE LEVER ACTION, SCHLAGE <br />OR APPROVED EQUAL TO MATCH BUILDING STANDARD. <br />FINISH LEGEND <br />FLOORING <br />MATERIAL: <br />LUXURY VINYL TILE <br />LVT-1 <br />MANUFACTURER, <br />TO BE DETERMINED <br />COLOR. <br />TO BE SELECTED BY TENANT <br />MATERIAL: <br />VINYL COMPOSITION TILE <br />VCT-I <br />MANUFACTURER, <br />TO BE DETERMINED <br />COLOR, <br />TO BE SELECTED BY TENANT <br />WALL BASE <br />MATERIAL: <br />4" COVED VINYL, 6" IN TOILET ROOMS) <br />B-1 <br />MANUFACTURER, <br />JOHNSONITE OR APPROVED EQUAL <br />COLOR, <br />TO BE SELECTED BY TENANT <br />PAINT <br />MATERIAL- <br />PAINT, LOW LUSTER <br />P-1 <br />MANUFACTURER, <br />BENJAMIN MOORE OR APPROVED EQUAL <br />COLOR- <br />TO BE SELECTED BY TENANT <br />MATERIAL: <br />PAINT, SEMI -GLOSS OIL BASED ENAMEL <br />P-2 <br />MANUFACTURER, <br />BENJAMIN MOORE OR APPROVED EQUAL <br />COLOR: <br />TO BE SELECTED BY TENANT <br />LOCATION, <br />DOOR FRAMES, METALS <br />MATERIAL, <br />PAINT, EPDXY <br />P-3 <br />MANUFACTURER, <br />BENJAMIN MOORE OR APPROVED EQUAL <br />COLOR: <br />TO BE SELECTED BY TENANT <br />LOCATIONS, <br />RESTROOMS AND WET AREAS <br />CEILING <br />MATERIAL, <br />2' X 2' ACOUSTICAL PANEL CEILING TILE <br />C-1 <br />MANUFACTURER, <br />USG OR APPROVED EQUAL <br />STYLE, <br />TO BE SELECTED BY TENANT <br />PROV1510N5 FOR 15A IZP IER FREE DOORS DOOR AND 1.4AIZDWAIZE COMPLIANCE NOTES <br />PULL SIDE x I. ALL DOORS OVER 7'-0" A.F.F. SHALL HAVE 2 PAIR BUTT <br />PUSH SIDE HINGES. <br />E 24 preferred Eg 2. HANDLES, PULLS, LATHES, LOCKS, AND OTHER <br />OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE <br />� , co A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND <br />DOES NOT REQUIRE TIGHT GRASPING, TIGHT -PINCHING, OR <br />TWISTING OF THE WRIST TO OPERATE. LEVER -OPERATED <br />MECHANISMS, PUSH -TYPE MECHANISMS, AND U-SHAPED <br />NOTE: x = 12 IN IF THE HANDLES ARE ACCEPTABLE DESIGNS. <br />DOOR HA TH A 3. HARDWARE REQUIRED FOR ACCESIBLE DOOR PASSAGE <br />CLOSER AND A LATCH. SHALL BE MOUNTED NO HIGHER THAN 48 INCHES ABOVE <br />(A) FRONT APPROAC14E5 FINISHED FLOOR. <br />4. BOTH SIDES OF ALL DOORS SHALL HAVE THE SAME <br />} } ELEVATION WITH NO MORE THEN 1/2" DIFFERENCE ON <br />PULL SIDE I EITHER SIDE. <br />..� x T TPUSH SIDE 5. THE FORCES REQUIRED TO FULLY OPEN FIRE -RATED <br />(LABELED) DOORS SHALL NOT EXCEED A 15 LBF TO RELEASE <br />THE LATCH, A 30 LBF TO SET THE DOOR IN MOTION AND A <br />15 LBF TO OPEN THE DOOR TO THE MINIMUM REQUIRED WIDTH. <br />THESE FORCES BEING APPLIED TO THE LATCH STILE. <br />NOTE x = 36 IN MINIMUM NOTE y - 48 N MIN. IF 6. EXTERIOR SWINGING DOORS SHALL BE OPENABLE BY A <br />IF y = 60 IN x = 42 IN DOOR HA TH A FORCE OF NOT MORE THAN 8.5 POUNDS APPLIED TO THE <br />MINIMUM IF y = 54 IN. LATCH AND A CLOSER. LATCH STILE. <br />(15) HINGE 61DE APPROACHES 7. PROVIDE BUILDING STANDARD DOOR STOPS, HINGES AND <br />SILENCERS AT ALL DOORS. <br />8. NON -RATED INTERIOR SWINGING DOORS SHALL BE <br />PULL SIDE OPENABLE BY A FORCE OF NOT MORE THAN FIVE (5) <br />24 min. PUSH SIDE POUNDS APPLIED TO THE LATCH STILE. <br />E x 24 m n. CI4AKE IN LEVEL COMPLIANCE <br />c0 x , E <br />a ~ I. CHANGES IN LEVEL OF 1/4 INCH NIGH MAXIMUM SHALL BE <br />PERMITTED TO BE VERTICAL. <br />NOTE, y = 54 IN MINIMUM NOTE y - 48 IN MIN. IF 2. CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MINIMUM AND <br />IF THE DOOR NASA THE DOO I A 1/2 INCH HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE <br />NOT STEEPER THAN 112. <br />CLOSER. CLOSER. <br />3. A CHANGE IN LEVEL OF 1/2 INCH IS PERMITTED TO BE 1/4 <br />(C) LATCH 510E APPROACHES INCH VERTICAL PLUS 1/4 INCH BEVELED, HOWEVER, IN NO <br />CASE MAY THE COMBINED CHANGE IN LEVEL EXCEED 1/2 <br />INCH. CHANGES IN LEVEL EXCEEDING 1/2 INCH MUST COMPLY <br />NOTE: ALL DOORS IN ALCOVES SHALL COMPLY WITH THE WITH RAMPS OR CURB RAMPS REQUIREMENTS PER THE <br />CLEARANCES FOR FRONT APPROACHES. MOST CURRENT ACCESSIBILITY CODE. <br />FIN16U NOTES <br />I. ALL FINISHES TO BE SELECTED BY TENANT AND <br />APPROVED BY OWNER. <br />2. COORDINATE AND VERIFY ALL FINISHES AND <br />LOCATIONS WITH TENANT. <br />3. CONTRACTOR TO PROVIDE MATERIALS AND SAMPLES <br />TO BE APPROVED BY OWNER AND TENANT PRIOR TO <br />ORDERING. <br />4. ALL WALLS TO BE SANDED AND PRIMED PRIOR TO <br />RECEIVING PAINT. <br />5. ALL WALLS TO BE PAINTED SHALL RECEIVE (2) TWO <br />COATS MIN. OF LATEX PAINT, OR MORE AS REQUIRED <br />FOR COMPLETE COVERAGE, IN A LOW LUSTER FINISH <br />COLOR OVER (1) COAT PRIMER OF SIMILAR COLOR. <br />6. ALL HIM DOOR AND/OR WINDOW FRAMES SHALL <br />RECEIVE (2) COATS OF SPECIFIED OIL -BASED ENAMEL <br />(P-2) OVER (1) COAT FACTORY PRIMER, <br />7. DOORS - ALL EXISTING INTERIOR DOORS TO RECEIVE <br />NEW FINISH IN AREA OF WORK. <br />FIN1514 MATERIAL COMPLIANCE NOTES <br />I. ALL WALL AND CEILING FINISH MATERIALS INCLUDING <br />VINYL AND RUBBER BASE, SHALL BE CLASSIFIED IN <br />ACCORDANCE WITH ASTM E-84 AND SHALL COMPLY WITH <br />CLASS B INTERIOR FINISH WITH FLAME SPREAD 26-75, AND <br />SMOKE DEVELOPED 0-450. EXCEPT AS NOTED BELOW. <br />2. ALL EXPOSED WOOD TRIM REGARDLESS OF FINISH, SHALL <br />BE OF A SPECIES OTHER THAN PINE AND IN NO CASE <br />SHALL THE FLAME SPREAD CLASSIFICATION EXCEED 200 <br />AND SMOKE DEVELOPED 0-450, AS A CLASS 'C' INTERIOR <br />FINISH MATERIAL. <br />3. MATERIALS LESS THAN 1/28 INCH THICK WHICH ARE <br />CEMENTED TO THE SUBSTRATE WHICH HAVE FLAME <br />SPREAD CHARACTERISTICS NO GREATER THAN PAPER OF <br />1/28 INCH THICKNESS DO NOT HAVE TO BE CLASSIFIED IN <br />ACCORDANCE WITH ASTM E-84. <br />4. MATERIALS SUCH AS CARPETING HAVING A NAPPED, <br />TUFTED, LOOPED, OR SIMILAR SURFACE WHEN APPLIED TO <br />WALL OR CEILING SHALL MEET THE REQUIREMENTS OF A <br />CLASS 'A' INTERIOR FINISH. <br />5. INTERIOR FINISH MATERIAL SHALL BE CEMENTED OR <br />OTHERWISE FASTENED IN PLACE SO THAT THEY WILL NOT <br />READILY BECOME DETACHED WHEN SUBJECTED TO ROOM <br />TEMPERATURES OF 300 DEGREES F. FOR 25 MINUTES. <br />6. FLOORING MATERIALS SHALL HAVE A MINIMUM OF CLASS <br />II INTERIOR FLOOR FINISH RATING AS CLASSIFIED IN <br />ACCORDANCE WITH NFPA <br />7. CARPET INCLUDING PAD, WHEN SPECIFIED, SHALL COMPLY <br />WITH CLASS II INTERIOR FINISH REQUIREMENTS NOTED <br />ABOVE. <br />8. IF CARPET OR CARPET TILE IS USED ON A GROUND OR <br />FLOOR SURFACE, THEN IT SHALL BE SECURELY ATTACHED, <br />HAVE A FIRM CUSHION, PAD, OR BACKING, OR NO CUSHION <br />OR PAD, AND HAVE A LEVEL LOOP TEXTURED LOOP, LEVEL <br />CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. THE <br />MAXIMUM PILE HEIGHT SHALL BE 1/2 INCH, EXPOSED EDGES <br />OR CARPET SHALL BE FASTENED TO FLOOR SURFACES <br />AND HAVE A TRIM ALONG THE ENTIRE LENGTH OF THE <br />EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH <br />303 CHANGES IN LEVEL SECTION OF THE FLORIDA BUILDING <br />CODE, ACCESSIBILITY. <br />9. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE <br />ROUTES AND IN ACCESSIBLE ROOMS AND SPACES, <br />INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB <br />RAMPS SHALL BE STABLE, FIRM, SHALL HAVE A SLIP <br />RESISTANT FINISH, AND SHALL COMPLY WITH 302 FLOOR OR <br />GROUND SURFACES AND 303 CHANGES IN LEVEL OF THE <br />FLORIDA BUILDING CODE: ACCESSIBILITY. <br />JUL 3_-� 202 <br />O <br />O cy) <br />z <br />O <br />Lo <br />0 <br />Q <br />_ <br />0 <br />Q <br />— <br />0 <br />O� <br />w <br />2 <br />>_ <br />L.L <br />- <br />z <br />J <br />Q <br />w <br />O <br />J <br />T. <br />0 <br />v <br />� <br />Lu <br />z <br />J <br />- <br />N <br />