Laserfiche WebLink
111 -1 L I I I I I I II- <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS <br />CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE WORK. <br />ALL WINDOWS AND DOORS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS <br />TO RESIST THE WIND LOADS INDICATED AND TO MEET OTHER CODE REQUIREMENTS FOR <br />AIR AND WATER INTRUSION. FOR BUILD-UP DOORS WINDOWS OR ACCESSORIES <br />PERMANENTLY ATTACHED THROUGH THE BODY OF �HE MATERIAL BEING FASTENED USE <br />10 WOOD SCREWS PENETRATING INTO THE ROUGH FRAMING MENBER AT LEAST 2" @ 12" <br />N CENTER, OR MASONRY ATTACHMENTS USE 3/16" X 1" EMBEDMENT "TITAN" OR "TAPCON" <br />HEX HEAD MASONRY ANCHORS © 12" ON CENTER. <br />WINDOW AND DOOR MANUFACTURERS TO PROVIDE CERTIFICATION/RATING THAT THEIR WINDOWS AND DOORS <br />WILL WITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING WIND <br />PRESSURE AND PROVIDE INSTALLATION INFORMATION WITH THEIR PRODUCTS. <br />CONTRACTOR TO INSTALL WINDOWS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEW BY THE <br />BUILDING INSPECTOR. <br />ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED <br />PROVIDE TEMPERED GLAZING IN ACCORDANCE WITH FBC FOR GLAZED, SLIDING, FIXED AND <br />SWING DOORS. ALSO SHOWER ENCLOSURES AND ALL GLAZING WITH 24 OF ALL DOORS. ALL <br />GLAZING 9.0 SQ FT OR GREATER, OR LESS THAN 18" A.F.F. SHALL BE TEMPERED. (FBC R308.4) <br />ALL EGRESS WINDOWS FROM SLEEPING ROOMS SHALL HAVE A MINIMUM CLEAR OPENING <br />OF 5.7 SQ. FT. (MIN OPENING SIZES = 2'-0" X 1'-8", SILL © 44" A.F.F. MAX) <br />ALL HURRICANE CLIPS, STRAPS AND FASTENERS ARE TO BE APPLIED ACCORDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS. IF DESIRED, EQUALVENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOWN. <br />HURRICAN CLIPS ARE REQUIRED ON ALL TRUSSES AND RAFTERS. IF PLYWOOD OR OSB SHEATHING DOES NOT OVER TOP PLATE, <br />HURRICANE CLIPS MUST BE COVER BOTH TOP PLATES. <br />UPLIFT PROTECTION: PLYWOOD OR OSB COVERING ENTIRE EXTERIOR OF HOME WITH NAILS SPACED 3" O.C. AT TOP AND BOTTOM, <br />6" O.C. ON EDGES AND THE REMAINDER AT 12" O.C. OR PLAYWOOD OR OSB AT CORNERS, WITH HURRICANE STRAPING ON EVERY <br />EXTERIOR STUD, CRIPPLE, JACKSTUD ETC. AT TOP AND BOTTOM. <br />NOTE: <br />AREA'S <br />LIVING (EXISTING) <br />600 <br />FRONT PORCH (EXISTING) <br />208 <br />FAMILY/KITCHEN <br />388 <br />MASTER BEDROOM/BATH <br />380 <br />DECK <br />140 <br />TOTAL AREA UNDER ROOF 1716 S.F. <br />R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN ALTERATIONS, REPAIRS OR ADDITIONS <br />REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN <br />EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED <br />AS REQUIRED FOR NEW DWELLINGS. <br />CONTRACTOR TO INSPECT AND INSURE THAT EXISTING HOUSE HAS SMOKE & CO DETECTORS AT EACH BEDROOM AND <br />AND OUTSIDE BEDROOMS WITHIN 10 FEET OF SLEEPING AREAS TO BE IN COMPLIANCE <br />PRODUCT <br />CATEGORY <br />MANUFACTURER <br />SERIES QR <br />MODEL # <br />APPROVAL # <br />FLA OR MIAMI <br />APPROVAL VERSION <br />EXTERIOR DOORS <br />SWINGING <br />JELD-WEN <br />PREMIUM ATLANTIC VINYL <br />11109.2 <br />FL 11109-R7 <br />THERMA-TRU <br />SMOOTH -STAR AND BENCHMARK <br />15225.2 <br />FL 15225-R4 <br />JELD-WEN <br />PREMIUM ATLANTIC VINYL <br />11112.2 <br />FL 11112-R5 <br />JELD-WEN <br />DESIGN PRO SMOOTH PRO <br />16674.1 <br />FL 16674-R12 <br />MASONITE <br />FIBERGLASS <br />22363.6 <br />FL 22363-R5 <br />PGT <br />FD-ALUM <br />253.4 <br />FL 253-R19 <br />SLIDING <br />PGT <br />SERIES 5570 <br />251.10 <br />FL 251-R31 <br />JELD-WEN <br />PREMIUM VINYL <br />12796.4 <br />FL 12796-RB <br />JELD-WEN <br />PREMIUM VINYL <br />21705.3 <br />FL 21705-R2 <br />SECTIONAL ROLL UP <br />CLOPAY <br />73, 75 9'2"-16'2" <br />16107.3 <br />FL 16107-R10 <br />73, 75 16'4"-18'2 <br />16107.11 <br />73. 75 UP TO 9'2" <br />16107.24 <br />WINDOWS <br />SINGLE DOUBLE HUNG <br />JELD-WEN <br />PREMIUM ATLANTIC VINYL <br />14095.1 <br />FL 14095-R10 <br />PGT <br />SERIES 5500 <br />239.7 <br />FL 239-R26 <br />MI WINDOWS & DOOR <br />SERIES 185 <br />17499.2 <br />FL 17499-R5 <br />HORIZONTAL SLIDER <br />PGT <br />HR-ALUM <br />242.3 <br />FL 242-R25 <br />MI WINDOWS & DOOR <br />SERIES 188 <br />15351.3 <br />FL 15351-R7 <br />JELD-WEN <br />PREMIUM VINYL <br />22368.1 <br />FL 22368-R3 <br />FIXED <br />PGT <br />PW-ALUM <br />243.9 <br />FL 243-R21 <br />MI WINDOWS & DOOR <br />SERIES 185 <br />15349.5 <br />FL 15349-R12 <br />MILLION <br />PGT <br />SERIES 5500 <br />261.1 <br />FL 261-R1 1 <br />MI WINDOWS & DOOR <br />SERIES 5764 <br />15353.2 <br />FL 15353-R4 <br />JELD-WEN <br />MILLIONS <br />15861.1 <br />FL 15861-R8 <br />PANEL WALL <br />SIDING <br />KAYCAN <br />SIDING <br />16299.2 <br />FL 16299-R4 <br />JAMES HARDIE <br />13192.2 <br />FL 13192-R5 <br />SOFFITS <br />KAYCAN <br />SOFFIT <br />16503.3 <br />FL 16503-R3 <br />ALSIDE <br />SOLID AND VENTED SOFFIT <br />15272.1 <br />FL 15272-R2 <br />JAMES HARDIE <br />SOFFIT <br />13265.1 <br />FL 13265-R3 <br />ROOFING <br />FL 15272-R2 <br />ASPHALT SHINGLES <br />GAF <br />SHINGLES <br />10124.1 <br />FL 10124-R22 <br />IKO <br />SHINGLES <br />15550.4 <br />FL 15550-R6 <br />TAMKO <br />SHINGLES <br />18355.1 <br />FL 18355-R4 <br />TPO <br />GAF <br />SINGLE PLY ROOF SYSTEMS <br />16730.1 <br />FL 16730-R23 <br />UNDERLAYMENT <br />TAMKO <br />15# <br />FELT <br />12328.6 <br />FL 12328-R8 <br />30# <br />ELT <br />12328.7 <br />GAF <br />UNDERLAYMENT <br />10626.1 <br />FL 10626-R15 <br />ROOF VENTILATORS <br />THOMPSON ARCH METAL <br />OFF RIDGE VENT <br />16918.2 <br />FL 16918-R2 <br />FLORIDA METAL PROD. <br />VENT RV10 <br />21580.3 <br />FL 21580-R1 <br />LOMANCO <br />DA-4 EXHAUST FAN <br />17202.1 <br />FL 17202-R4 <br />STORM PANELS <br />GLOBAL PROTECTION PROD <br />GALV STEEL STORM PANELS <br />15076.1 <br />FL 15076-R5 <br />15076.2 <br />STRUCTURAL COMPONENTS <br />CAST-CRETE USA <br />CONCRETE LINTELS <br />158.1 <br />FL 158-R7 <br />COMMERCIAL CONCRETE PRODUCTS <br />CONCRETE LINTELS <br />1774.1 <br />FL 1774-R4 <br />MARION MASONRY MATERIALS <br />CONCRETE LINTELS <br />12193.1 <br />FL 12193-R3 <br />CONCRETE PRECAST PRODUCTS <br />CONCRETE LINTELS <br />15148.1 <br />FL 15148-R2 <br />LOTT'S CONCRETE PRODUCTS <br />CONCRETE LINTELS <br />17867.1 <br />FL 17867-R1 <br />EXISTING CEILING IS 7'-4" <br />CEILING HEIGHT 8' NEW ADDITION <br />0V) <br />z(/) <br />F77 L.LJ <br />V)Q:� <br />X0 <br />wW <br />CD <br />z <br />X <br />LiJ <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />24' <br />4" <br />SH24 ,_8„ <br />29'-8" <br />FL0011' PL-"- I <br />9 <br />�`_ �� �.• ..+ a 11111-*� <br />••_ s.�r <br />aA � � • <br />No.536 <br />STA p <br />i <br />: <br />!: 0 •L <br />00 <br />A L E� <br />MONTEALEGRE WILMAN <br />5339 4TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE:813-469-8289 E-MAIL: dwsflpe@earthllnk,net <br />RICK GOLLHARDT - DRAFTSMAN <br />813-781-3651 <br />rgollhardt@tampabay. rr. com <br />FLOOR PLAN <br />SHEET OF <br />2 OF 7 <br />SCALE DATE JOB NO, <br />Do NOT SCALE 10 MAR 2020 <br />DESIGN/DRAWN CHECKED 2020-1 1 12 <br />R. COLLHARDT D.W.S.,p.e. <br />ENGINEER LICENCE #53608 <br />