Laserfiche WebLink
NA I L I N(5 5GHEDULE <br />ALL NAILS ARE d GOMMON NUMBER AND 5PAGIN6 <br />LEDGER STRIP <br />Ibd <br />3 6 EA. J015T <br />50LE PL. TO J015T OR BLK'6-FAGE NAIL <br />Ibd <br />Ib' D.G. <br />TOP OR SOLE PL. TO STUD -END NAIL <br />Ibd <br />2 <br />STUD TO SOLE PL.-TOE NAIL <br />8d/Ibd <br />3/2 <br />DBL. 5TUD5-FACE NAIL <br />IDd <br />24" O.G. <br />DBL. TOP PLATES -FACE NAIL <br />IOd <br />Ib" O.G. <br />GONTINUOU5 HD'R TWO PLAGE5 <br />Ibd <br />Ib" O.G. ALONG EA. EDGE <br />GONTINUOU5 HD'R TO 5TUD-TOE NAIL <br />Sd <br />3 <br />IX8 5HEATHIN6 OR LE55 TO EA. 13RN'6-FAGE NAIL <br />Sd <br />2 <br />OVER IX8 5HEATHIN6 TO EA. BRN'6-FA(E NAIL <br />8d <br />2 <br />BUILT UP CORNER 5TUD5 <br />IOd <br />24" O.G. <br />BUILT UP 61RDER5 AND BM5 UP TO TRU55 MEMBER5 <br />IDd <br />32' O.G. ® TOP AND BOTT. AND 5TA66EREP <br />2 END5 ® EA. 5PLIGE <br />1/2" 6YP5UM 5HEATHIN6 <br />II 6A. 1-1/2" 6ALV.1/16" HEAD. <br />4" ON EDGE 8" IN FIELD <br />5/8" 6YP5UM 5HEATHIN6 <br />II 6A. 1-3/4" 5ALV. Nib" HEAD. <br />4" ON EDGE 8" IN FIELD <br />1/2" 6YP5UM WALLBOARD <br />1-3/8" DRYWALL NAIL 1/I6" HEAD. <br />-I" ON GEILING 8" ON WALL5 <br />5/8" GYPSUM WALLBOARD <br />1-1/2" DRYWALL NAIL 1/Ib" HEAD. <br />l" ON GEILING b' ON WALLS <br />HARD BD.. LAP 51DIN6-DIREGT TO 5TUD <br />8d GORRO510N RE515TANT H/ MIN. <br />SHANK PIA. OF .Oqq" AND A MIN. <br />HD. PIA. OF .24' <br />16' O.G. ® TOP AND BOTTOM EDG-E5 <br />HARD BD.. LAP SIDING OVER 5HEATHIN6 <br />IDd GORR05ION R-51STANT W/ MIN. <br />SHANK DIA. OF .Oqq" AND A MIN. <br />HD. DIA. OF 24" <br />16' O.G. ® TOP AND BOTTOM E06E5 <br />HARD BD.. PANEL 510IN5 DIREGT TO 5TUP5 <br />8d CORRO51ON RE515TANT H/ MIN. <br />5HANK DIA. OF .Oq2" AND A MIN. <br />HD. DIA. OF 225" <br />b" O.G. ® ED6E5 AND 12" O.G. <br />INTERMEDIATE 5UPPORT5 <br />HARD BD.. PANEL 51DIN6 OVER 5HEATHIN6 <br />8d GORRO510N RE515TANT W/ MIN. <br />5HANK DIA. OF .Oq2" AND A MIN. <br />HP. DIA. OF 225" <br />6" O.G. ® E06E5 AND 12" O.G. <br />INTERMEDIATE 5UPPORT5 <br />NAILING SCHEDULE <br />ATTIC VENTILATION CALCULATIONS <br />TOTAL ATTIC <br />AREA = <br />768 S.F. <br />185 MINIMUM <br />SQ. IN. <br />OF NET FREE AREA OF EXHAUST <br />NEEDED OR NEAR THE RIDGE <br />185 MINIMUM <br />SQ. IN OF NET FREE AREA OF INTAKE NEEDED AT OR NEAR THE SOFFIT <br />TOTAL SQ IN <br />RIDGE <br />VENT = 506 SQ IN 2'-0" X <br />23/LF <br />TOTAL SQ IN <br />SOFFIT <br />VENT = 936 SQ IN 72'—O" X <br />13/1_F <br />ATTIC ACCESS <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SO. FT. AND HAVING <br />MINIMUM 30 INCHES OF VERITAL HEIGHT, ROUGH FRAMED OPENING NOT BE LESS THAN 22"X30" <br />INCHES. WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC IT SHALL BE INSTALLED IN <br />ACCORDANCE WITH FLORIDA BUILDING CODE 6TH EDITION 2017 RESIDENTIAL —SECTION 807 <br />UPLIFT CONNECTION — SIMPSON STRONG —TIE <br />FRAME APPLICATIONS <br />MARK <br />CONNECTOR <br />UPLIFT <br />CAPACITY <br />LATERAL <br />CAPACITY <br />FASTENERS <br />FLORIDA <br />APPROVAL # <br />A <br />H2.5A <br />600 <br />150 <br />10-8d X 1-1/2" <br />10456.11 <br />H10 <br />990 <br />525 <br />16-8d X 1-1/2" <br />10456.6 <br />VTC2 <br />405 <br />4— 10d <br />5-10d X 1-1/2 <br />10861.5 <br />NOTE: CONNECTOR CAPICITIES ARE FOR SYP, REFER TO MANUFACTURERS <br />FOR ADDITIONAL INFORMATION <br />LEGEND <br />® H2.5A <br />© VTCZ <br />2017 FBC RESIDENTIAL SECTION R703.4 FLASHING <br />APPROVED CORRISION RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN A MANNER TO PREVENT ENTRY <br />OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURE FRAMING COMPONENTS. <br />SELF ADHERED MENBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />PRODUCTS SHALL BE SEALED AT THE JUNCTION WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA <br />800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION. ASTM <br />C 1281 AAMA 812 OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID APPLIED <br />MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE INSTALLED AT <br />THE FOLLOWING LOCATIONS. <br />1. <br />EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER COMPLYING WITH SECTION <br />703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA <br />712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE FOLLOWING. <br />1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS OR THE APPLICATIONS <br />NOT ADDRESSED IN THE FENESTRATION MANUFACTURERS INSTRUCTIONS IN ACCORDANCE WITH THE <br />FLASHING MANUFACTURERS INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT <br />PROVIDED PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS <br />PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER FOR SUBSEQUENT DRAINAGE <br />OPENINGS USING PAN FLASHING SHALL BE INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES <br />MORE OF THE FOLLOWING. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS <br />1.4 IN ACCORDANCE WITH FMA/AMMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AMMA/WDMA 300 <br />OR FMA AAMA/WDMA 400 <br />2. <br />AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS <br />3. <br />UNDER AND AT THE ENDS OF MASONRY WOOD OR METAL COPINGS AND SILLS <br />4. <br />CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />5. <br />WHERE EXTERIOR PORCHES, DECKS AND STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION <br />J`4.,N cE•• i� <br />6. <br />AT WALL AND ROOF INTERSECTIONS <br />``` <br />7. <br />AT BUILT—IN GUTTERS <br />Is <br />O w <br />�' <br />No.53"° <br />,�,•��: <br />:`moo ;• • lopo <br />•..i...y <br />d� <br />1$11, N L <br />` <br />i <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />ENGINEER LICENCE #53608 <br />STANDARD <br />SHEATHING TO BE 15/32" OSB OR 1/2" PLY CDX W/Bd RING SHANK NAILS <br />® 3" O.C. BOUNDARIES, 6" O.C. EDGES do 8" O.C. FIELD <br />USE STEEL PLYCLIPS. <br />(2) 16d TOENAILS <br />INTO EACH LEDGER. <br />2"x 4" LEDGER. (2) 12d <br />TO EACH TRUSS WEB. <br />(2) 2X4 45 DEGREE <br />DIAGONAL BRACING SPACED <br />® 48" O.C.. (4) 16d NAILS <br />® EACH END: (TYP) <br />2x4 PANEL BLOCKING ® 48" O.C. <br />FOR THE FIRST 8'-0" OF END WALL <br />FROM EA. END TYP. BOTTOM CORD <br />ATTACH D W/ (2) 16-d TOENAILS <br />7 <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH DBL. TOP PLATE <br />10dx3" ® 4" O.C. <br />2"x 4" TOP CORD BLOCKING ® 48' O.C. FOR <br />FIRST FOUR ROWS OF TRUSSES 0 EDGES OF <br />SHEATHING TYP.. BACK NAIL AND TOE NAIL <br />ALTERNATE ENDS W/ (2) 16d NAILS. <br />2'-0" <br />FRAME <br />/— SOFFIT AND FASCIA <br />DOWNSET TOPCHORD OF <br />GABLE END TRUSS TO RUN <br />2"x 4" OUTLOOKERS SPACED <br />® 24" O.C. (1) SIMPSON H5 <br />® EACH OUTLOOKER <br />-"L" BRACE TO EXTEND AT LEAST <br />90% OF WEB LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" COX PLYWOOD OR 7/16" OSB <br />SHEATHING ATTACHED W/ 8d <br />RINGSHANK NAILS Q 4" O.C. EDGES <br />AND 8" O.C. FIELD <br />-SIMPSON HGA10 ® 24" O.C. <br />STUD WALL (SEE TYP. SEC.) <br />SIMPSON SP2 OR SP4 <br />EACH STUD <br />5/8" OR 1/2" COILING DENSE <br />GYPSUM WALL BOARD FASTENED <br />WITH 8d COOLER NAILS OR 1 1/4" <br />LONG DRYWALL SCREWS COMPLYING <br />WITH ASTM C1002 FOR FIRST 8'-0" <br />FROM END WALL ® 4" O.C. TYP. <br />GABLE END BRACING DETAIL <br />HIP & RIDGE CUT <br />FROM METRIC <br />THREE TAB SHINGLES <br />PREVAILING 5 ---\ <br />WIND DIRECTION <br />'--5 5/8" FAST <br />DI,S,TANCE <br />STANDARD <br />MANSARD OR <br />NORMAL WIND AREAS HIGH WIND AREAS <br />o. <br />5" EXPOSURE <br />SHINGLE NAILING NOTES: <br />ALL NAILS MUST PENETRATE AT LEAST 3/4" INTO <br />THE WOOD ROOF DECK. <br />NAIL SHINGLES WITH 11 OR 12 GAUGE GALVANIZED NAILS <br />WITH 3/8" DIAMETER HEADS - 6 REQUIRED (AS SHOWN <br />IN "HIGH WIND AREAS") <br />RnnF_Tn_wAi I P-I ACI--IINr NInTF71Z- <br />4" X 5" ANGLE FLASHING - 26 GAUGE GALVANIZED METAL, <br />RUBBER VALLEY FLASHING OR 12" WIDE - 26 GAUGE <br />GALVANIZED METAL WITH SHINGLES OVER THE TOP. <br />MATERIAL SPECIFICATIONS: <br />UNDERLAYMENT SHALL CONFORM TO ASTM D226, TYPE I <br />OR ASTM 4869, TYPE I. <br />ENING FLASHING FOR ASPHALT SHINGLES SHALL COMPLY WITH <br />FBC R905.2.8 <br />ASPHALT SHINGLES SHALL COMPLY TO ASTM D225 OR <br />ASTM D3462. <br />VALLEY LINER - <br />UNDERLAYMENT <br />2» <br />—6" MIN. <br />EXTRA NAIL <br />ASPHALT PLASTIC <br />CEMENT <br />CLIP <br />CORNER <br />ROOF SHINGLE 8c FLASHING INSTALLATION SPEC'S <br />NOT TO SCALE <br />MONTEALEGRE WILMAN <br />5339 4TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53808 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE—DADE CITY, FLORIDA 33525 <br />PHONE:813-469-2289 E-MAIL: dwsflpe@earthllnk.net <br />RICK GOLLHARDT — DRAFTSMAN <br />813-781-3651 <br />rgollhardMampabay. rr. com <br />TRUSS PLAN SHEET OF <br />4 OF 7 <br />SCALE DATE JOB NO. <br />DO NOT SCALE 10 MAR 2020 <br />DESIGN/DRAWN CHECKED 2020-1 1 12 <br />R. GOLLHARDT D.W.S.,p.e. <br />