Laserfiche WebLink
I_ I 1 '!1 i I 1 111 11 j I I11 11 11 1I I I-L. I! I I I I I I I I I_'.. <br />MECHANICAL: <br />CONDENSATE LINES SHALL DISCHARGE AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. <br />2017 FMC, 6TH EDITION — EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT. <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />NOTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />6TH EDITION, 2017 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01/08 AND HAVING A <br />FOSSIL— FUEL— BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2017 6TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII — ELECTRICAL) <br />NEC 2017: 210.12 — ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 — INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. <br />ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO <br />BE: 12" AFF (GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. <br />ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE POSSIBLE <br />3. <br />ELECTRICAL SWITCHES TO BE 42" <br />CENTERLINE AFF. <br />4. <br />ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR <br />WHO SHALL BE RESPONSIBLE <br />FOR THE INSTALLATION & SIZING OF <br />ALL ELECTRICAL, WIRING & ACCESSORIES. <br />5. <br />GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER N.E.C. 2017 <br />SYMBOL DESCRIPTION <br />SWITCH <br />$3 3 WAY SWITCH <br />$4 4 WAY SWITCH <br />$R RHEOSTAT SWITCH <br />110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />6GFI 110 V RECEPTICLE - GROUND FAULT <br />6AFI 110 V RECEPTICLE - ARC FAULT <br />6wp 110 V RECEPTICLE - WATERPROOF OUTLET <br />6 220 V RECEPTICLE <br />DUPLEX OUTLET IN FLOOR <br />110 V QUAD <br />lbwp 110 V QUAD WATERPROOF OUTLET <br />RECESSED INCANDESCENT <br />} LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />® FLOURESCENT FIXTURE <br />Qp FLOOD LAMPS <br />VANTITY LIGHT <br />GD PUSH BUTTON FOR GARAGE OPENER <br />S&o SMOKE /FIRE DETECTOR/ALARM <br />C&M SMOKE/CARBON MONOXIDE DETECTOR - COMBO <br />© CARBON MONOXIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN W/L <br />a DISCONNECT <br />ELECTRICAL METER <br />O ELECTRICAL PANEL <br />3— 2/0 THNN CU FEEDERS <br />2" GALV RISER <br />2" CHASE W 210 <br />OR (3) #410/TVAL. THW COP. <br />200 AMP MAIN BREAKER <br />200 AMP 40 CIRCUIT SURFACE MOUNT <br />METER SOCKET PANEL ON INSIDE GARAGE WALL <br />METER SOCK4ET <br />0 0 <br />2" GALV NIPPLE <br />UNDERGROUND SERVICE <br />(IF AVAILABLE) #4 DRIVEN GROUND <br />RODS <br />2 EACH 8'-0" APART MIN. <br />\'�-3/8" X 8' GROUND ROD <br />CONCRETE ENCASED "UFER" ELECTTODE REQUIRED PER ART 250-50 <br />N.E.C. MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT. <br />rf'�_"LEC T-R, ICA L PLAIV <br />M O NTEALEG R E WI LMAN RICK GOLLHARDT - DRAFTSMAN <br />5339 4TH STREET 813-781-3651 <br />Z EP HYR H I LLS, FLORIDA rgollhardt@tampabay.rr.com <br />D.W.SMIT H9M.S.,P.E.#53608 ELECTRICAL/HVAC SHEET OF <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 7 OF 7 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE—DADE CITY, FLORIDA 33525 SCALE DATE JOB NO, <br />PHONE: 813-469-2289 E-MAIL: dwsftpe@ecLrthlink.net DO NOT SCALE 10 MAR 2020 <br />DESIGN/DRAWN CHECKED 2020-1 1 12 <br />R. GOLLHARDT D.W.S. <br />