Template:
Building Plans
Street #
5725
Location
14th St
Contractor
Levitsky-Owner
Building Plans - Permit #
1046
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 2308. 7. 3. 1 <br />RAFTER TIE CONNECTIONS g <br />RAFTER SLOPE <br />TIE SPACING <br />(inches) <br />NO SNOW LOAD Roof span <br />( feet) <br />12 20 28 <br />36 <br />Required number of 16d common (3j" <br />x 0. 162") nails a, b per <br />connection c, d, e, f <br />12 <br />4 <br />6 <br />8 <br />10 <br />16 <br />5 <br />7 <br />10 <br />13 <br />3: 12 <br />24 <br />7 <br />11 <br />15 <br />19 <br />32 <br />10 <br />14 <br />19 <br />25 <br />48 <br />14 <br />21 <br />29 <br />37 <br />12 <br />3 <br />4 <br />5 <br />6 <br />16 <br />3 <br />5 <br />7 <br />8 <br />4: 12 <br />24 <br />4 <br />7 <br />10 <br />12 <br />32 <br />6 <br />9 <br />13 <br />16 <br />48 <br />8 <br />14 <br />19 <br />24 <br />12 <br />3 <br />3 <br />4 <br />5 <br />16 <br />3 <br />4 <br />5 <br />7 <br />5: 12 <br />24 <br />4 <br />6 <br />8 <br />10 <br />32 <br />5 <br />8 <br />10 <br />13 <br />48 <br />7 <br />11 <br />15 <br />20 <br />12 <br />3 <br />3 <br />3 <br />4 <br />16 <br />3 <br />3 <br />4 <br />5 <br />7: 12 <br />24 <br />3 <br />4 <br />6 <br />7 <br />32 <br />4 <br />6 <br />8 <br />10 <br />48 <br />5 <br />8 <br />11 <br />14 <br />12 <br />3 <br />3 <br />3 <br />3 <br />16 <br />3 <br />3 <br />3 <br />3 <br />12: 12 <br />24 <br />3 <br />3 <br />3 <br />4 <br />32 <br />3 <br />3 <br />4 <br />5 <br />48 <br />3 <br />4 <br />6 <br />7 <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound <br />per square foot = 47.8 N/m2. <br />a. 40d box ( 5" x 0. 162, ) or 16d <br />sinker (31" x 0. 148") nails are permitted' to be <br />substituted for 16d common (3j" x 0. 16") nails. <br />b.Nailing requirements are permitted to be reduced 25 <br />percent if nails are clinched. <br />c.Rafter tie heel joint connections are not required <br />where the ridge is supported by a load -bearing wall, <br />header or ridge beam. <br />d.When intermediate support of the rafter is provided <br />by vertical struts or purlins to a load -bearing wall, <br />the tabulated heel joint connection requirements are <br />permitted to be reduced proportionally to the reduction <br />in span. <br />e.Equivalent nailing patterns are required for ceiling <br />joist to ceiling joist lap splices. <br />f.Connected members shall be of sufficient size to <br />prevent splitting due to nailing. <br />g.For snow loads less than 30 pounds per square foot, <br />the required number of nails is permitted to be reduced <br />by multiplying by the ratio of actual snow load plus 10 <br />divided by 40, but not less than the number required <br />for no snow load. <br />Truss Systems Engineering by others <br />TRUSS MANUFACTURER TO <br />PROVIDE SIGNED AND <br />SEALED TRUSS DRAWINGS <br />INCLUDING BRACING <br />DETAILS. <br />■ <br />Simpson H10A (or equal) <br />Installed per Manuf. specs. <br />Uplift is less than 1340 Lbs. <br />II <br />II <br />II <br />II I <br />I I <br />- - - - - - - - - - - r F_ <br />I I I I I I I I <br />I I I I I I I 1 <br />{� �l I <br />WH <br />I I I <br />(2)2x8's (2)2x5's I I <br />i <br />(2)2x8's I <br />LJ I <br />L_-_I <br />►I I �� I <br />------------L---rE <br />---------_CrtE"� <br />-L= I <br />I I <br />I I I I - - - - - - - - - - - - I I I <br />II L------------------ <br />II <br />II � II I III I <br />II II 11 III, <br />m 2' 4' � � O O � � � 'M■+f <br />B1C <br />^---------------------------------- <br />I I <br />I I <br />�_- -_- =------- 1-d <br />-----------_�-=---------------------------------------------- ��- - <br />L T-_----------�-� <br />I ----_-__ WIN/DR HGT. <br />I I IF 1 I IF I <br />I rl=%��, I II II Il II II/��1���I I <br />I====-TI 10 =___� I II <br />I I�� ��I ► II <br />L24 SF+JI IL 24 3HJ1 I II II II II IN�I <br />I L ____� I I II II II II III I <br />1j�1- I I 11LL-A�-_A� I <br />fi- - - - - - - - - - - - - - - - - - - - - - - la �- FF. ELEV. - <br />-�-�-1' I I E I L E F T S I D <br />1e 0XISTING <br />rZ V A T I O N <br />PRE-ENGINEERED ROOF TRUSSES CONY. FR4MING <br />---------------------------------- <br />I I <br />FIBERCxLASS <br />SHIWzLES <br />-------------- _ _ CL.G. HGT. <br />----------= =---------- ====1-J--------------------------------------------- ------ - <br />I I - - - - - - - - --WIN/)R. HGT. <br />�� <br />I ILI -- I I <br />II <br />if <br />TIONS) II I IlZ���1 i IL- 24 -JI IL-24 J1 III II II II j <br />I���AwN �� 1 u n n u n I <br />11 I I 11 LL--A LL A I / I i <br />FF.ELEv. <br />----------- --- --------------- <br />vATION <br />son H10A (or equal) <br />a [led per Manuf. specs. <br />Ft is less than 1340 Lbs. <br />ATTIC VENTILATION - FLORIDA BUILDING CODE <br />Total Area Under Roof <br />312.00 <br />Square Feet (SF) <br />Total Required Ventilation <br />2.08 <br />SF <br />Total Area / 150 <br />Area <br />Total Required Ventilation <br />1.04 <br />SF <br />Reqd Area 12 <br />Area at Soffits <br />Total Required Ventilation <br />1.04 <br />SF <br />Reqd Area / 2 <br />Area at Roof <br />Overhang Dirnension <br />2.00 <br />Feet <br />Ventilation Examples -Owens Corning <br />Ventilation <br />Required <br />At Soffit <br />Units <br />Units <br />Capacity <br />Vent <br />Triple 4" Center Vent <br />1.56 <br />sq in / ft <br />48.00 <br />Feet <br />Triple 4" Full Vent <br />4.68 <br />sq in / ft <br />16.00 <br />Feet <br />Double 5" Full Vent <br />425 <br />sq in / ft <br />21.15 <br />Feet <br />Ventilation <br />Required <br />At Roof <br />Units <br />Units <br />Capacity <br />Vent <br />Ventsure Metal Dome <br />144 <br />sq in <br />2 <br />Vents <br />w ith Screen <br />Ventsure high Profile <br />Slant Back Roof Vent w/ <br />50 <br />sq in <br />3 <br />Vents <br />Exterior Louver <br />Ventsure Plastic Slant <br />Back Roof Vent wJ <br />61 <br />sq in <br />3 <br />Vents <br />Interior Louver <br />Ventsure Rigid Strip <br />Ridge Vent, Externally <br />15 <br />sq in / ft <br />10 <br />Feet <br />Baffled <br />WIND DE51GN INFORMATION <br />I. Wind Speeds of 1313 MPH Vult 4 108 MPH Vasd <br />2. Risk Category = II <br />3. Exposure Category B <br />4. Enclosed Building, (GCpi = +/- 0.18) <br />5. Component 8 Cladding Pressures (PSF). <br />R = 18.2,-1&Yo' W = 332,-43.4 OH= -110.6 <br />NOTE- WIND LOAD CALCULATIONS ARE BASED ON <br />'WORST CASE' . ALL CONNECTORS WILL BE UNIFORM <br />FOR SIMILAR USES. <br />THIS STRUCTURE HAS BEEN DESIGNED TO WITHSTAND <br />INTERNAL PRESSURES, ENCLOSED BUILDING. <br />i <br />2319. 17. 1. 2 <br />Where a ceiling is to be attached directly to the underside of trusses, <br />the trusses shall be laterally braced with continuous 1-inch by 4-inch <br />(25 mm by 102 mm) members nailed with 8d common nails to the upper side <br />of the bottom chord at panel points but not to exceed 10 feet (3 m) <br />apart. This lateral bracing shall be restrained at each end and at <br />20-foot (6 m) intervals. Drywall may be considered a rigid ceiling in <br />enclosed areas where it is protected from the elements. The drywall <br />ceiling is not to be considered a ceiling diaphragm. <br />n-A noncr DDnnTnin ra DTnnE" <br />TOP/BOTTOM CHORD GABLE <br />END BRACING @ 48" 0. C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES <br />u <br />n <br />z <br />CONT. BOTTOM CHORD <br />BRACING (1"x4" MIN.) @ <br />10' -0" MAX. <br />SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY <br />ADDITIONAL BRACING OR CROSS BRACING REQUIREMENTS <br />REQ. MINIMUM TRUSS BRACING <br />GABLE <br />2"X4" Vertical Brace <br />added to every Vertical <br />over 4' in length. Brace <br />to be minimum 8051. length <br />of Vertical Truss Member. <br />Fasten Brace to Vertical <br />w/16d Common Nails 12" o.c. <br />END TRUSS <br />END <br />2 "X4" Nailer - <br />Lateral Bracing installed per <br />Pre-engineered Truss Plans <br />24" O.G. <br />2X4x8 LATERAL <br />BRACING CONTINOUS <br />a 48" O.C. <br />) 16d NAILS <br />DIAGONAL BRACE DETAIL <br />Typical Interior Truss <br />" S.R Gypsum Ceiling Board <br />Bottom Chord of Truss <br />fastened to wall top plate <br />w/166 common Nails <br />6 12 "o.c. <br />Wa I I Studs <br />Simpson LST18 (or equal) <br />fastened w/ 14-10d Nails. <br />TYPICAL END TRUSS TO FRAME WALL DETAIL <br />SCALE: NTS <br />BUILDING CONSTRUCTION NOTES <br />1. This single family dwelling is to the roth Edition (2011) FEBC (Florida Building Code) type <br />construction requirements. Construction shall comply with local County and state agencies. <br />2. All openings around walls, partitions, pipes, ducts, conduits etc_, shall be sealed fully <br />and sound proofed with sealants of type for application. <br />3. Painting_ All surfaces shall be properly prepared and cured to manufacturer's <br />instruction prior to painting. Paint shall be "first line" produced by PORTER, SHERWIN <br />WILLIAMS, or equal with colors selected by the owner. All painted surfaces shall be <br />painted with materials appropriate for the application in a workmanship manner to the <br />paint manufacturer's instruction. <br />4. Caulk all exposed joints. Clean, prime, caulk and seal all joints between door and <br />window frames with DOW CORNING silicon of type for application. Use foam back-up <br />rods as required at wide joints. Use acoustical foam sealants by DAP or TREMCO at <br />sound proofing applications at openings or cracks. <br />5_ Energy Code - These plans where designed with common design practices_ However, this does not <br />guarantee that this plan will pass the "Florida Energy Code". These plans shall be reviewed by a <br />proper HVAC professional and shall pass the "Florida Energy Code" or recommendations from such <br />Professional shall be provided to the Home Designer (Corner Stone Design Group, Inc.) so as to <br />meet such requirements. <br />O <br />C <br />Q <br />O <br />L <br />C <br />rn <br />N <br />0 <br />O <br />O <br />-41 <br />07 <br />L <br />0 <br />L <br />O <br />U <br />O <br />N <br />O <br />N <br />8 <br />0 <br />D_ <br />O <br />U <br />b <br />01 <br />00 <br />00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.