Laserfiche WebLink
N <br />14'-0 1/2" <br />10 <br />II <br />I <br />I U <br />II <br />I <br />l'-5 1/2" <br />I <br />O <br />I <br />I <br />3-1/2" CONCRETE w/6"X 6"X <br />I 10/10 W.W. MESH REINFORCING <br />M <br />I REQUIRED THROUGHOUT THE <br />CONCRETE SLAB OR SYNTHETIC <br />FIBER REINFORfSEMENT <br />I 5e W/CELL POURED SOLID e <br />- - - --� <br />S'-0" O.G. MAX (STEM WALL) <br />(BELOW FINISHED FLOOR) <br />_ I <br />I <br />----------- <br />I ° ° I <br />L- ---- = ID <br />-------- ----- <br />i 1I j > <br />� 1I I � --► I <br />3'-0" 5'-5 1/2" <br />II <br />f�l I I <br />III I I <br />*5X 12" REBAR <br />10 48" O.C. (TYP.) <br />II <br />II <br />II <br />I I I I I I <br />I I I I I I <br />I I I I I I <br />11 I I I I <br />I I <br />1 1 I I I <br />N f 1 I I I <br />/W14/ I I I I 1 1 <br />I��I <br />I IE 11 <br />I LJ I--- `LL <br />L---1I \ r---I \ <br />■ <br />11 I <br />----------1-----3 L----------- <br />-1 r------ r- <br />1I <br />II IL- I I <br />II L-----------------iI <br />I <br />1NJ <br />II II III II <br />I L-_-J I III II <br />_ _ I <br />Ir -n ii IIIlI <br />i I II I I <br />I I II <br />I I II ILA of <br />I I II I <br />..r-..F, I I IFOUNDAT I ON <br />Ne 1N FI5 NOTES - <br />(I.) ALL WORK TO BE DONE ACCORDING TO 6th Edition (2011) FEBC (Florida Building Code) <br />(2.) ASSUMED SOIL BEARING CAPACITY TO BE 2000 PSF. SOIL CAPACITY TO BE <br />VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION_ INFORM ENGINEER OF <br />VARIATIONS. FOOTINGS TO BE EXCAVATED TO CLEAN SOIL, FREE OF VEGETATION <br />AND DELETERIOUS MATTER. CONCRETE SHALL BE PLACED ON AN UNDISTURBED <br />BASE. <br />(3.) IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION <br />PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS <br />COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE <br />ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, OR TIE DOWNS THAT MAY <br />BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE <br />PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. <br />(4.) ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS <br />SHALL BE VERIFIED AND SHALL CONFORM TO THE ARCHITECTURAL DRAWINGS. <br />(5.) CONCRETE : <br />MINIMUM COMPRESSIVE CONCRETE STRENGTH TO BE 3000 PSI IN 28 DAYS. ALL <br />CONCRETE SHALL BE READY MIXED" AND iN ACCORDANCE WITH A.S.T.M. <br />SPECIFICATION C-24. ALL CONCRETE MODULAR UNITS SHALL HAVE A <br />COMPRESSIVE STRENGTH OF 1900 PSI WITH TYPE M OR S MORTAR, 2000 PSI_ <br />(6.) SLAB ON FILL : <br />INTERIOR CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF <br />MEMBRANES. ALL SLABS TO BE REINFORCED WITH C6Xro 10/10 WELDED WIRE MESH. <br />(1) LUMBER <br />1. STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED. <br />2. CURRENT EDITION, ASSOCIATION GRADING RULES GOVERN. <br />3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW <br />AGENCY. <br />4. ANY SPECIES ALLOWED UNLESS OTHERWISE NOTED. <br />5. SIZES ARE NOMINAL. ACTUAL SIZES SHALL CONFORM TO AMERICAN <br />LUMBER STANDARD PS 20-10. <br />6_ MOISTURE CONTENT OF LUMBER 2" OR LESS IN THICKNESS SHALL BE IS <br />OR LESS AT THE TiME OF INSTALLATION. <br />(8.) TERMITE TREATING; <br />SOIL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0" <br />BEYOND THE PERIMETER LINES OF THE BUILDING. <br />03.) ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3" AGAINST <br />SOIL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE <br />REBAR. <br />(10.) 2"X12" HEADERS SHALL BE 2-2"XI2" LAMINATED W/ 1/2" PLYWOOD GLUED W/ <br />CONSTRUCTION ADHESIVE AND NAILED W/ 5-016D COMMONS f6" O.G. TO MEET <br />LOADS AS INDICATED. <br />(11.) ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS. <br />(12.) CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATIONS (CUT SHEETS) <br />ON SITE AT THE TIME OF INSPECTION, FOR REVIEW BY THE BUILDING INSPECTOR, <br />TO MEET LOADS AS INDICATED. <br />THE FOUNDATION HAS BEEN DESIGNED FOR A <br />MINIMUM LOAD -BEARING PRESSURE OF 2000 <br />POUNDS PER SQUARE FOOT <br />Ll5xr=ND <br />ALL CMU WALLS CONSIDERED SHEAR WALL <br />■ CELL POURED SOLID w/ (IT'S <br />FROM FTG_ TO BOND BEAM <br />* O W/CELL POURED SOLiD <br />a 8'-0" O.C_ MAX. (STEM WALL) <br />- - CONTROL JOINT (SAW CUT) <br />100-00' FINISHED FLOOR ELEVATION <br />(ASSUMED DATUM) <br />e <br />'Fth ' <br />u <br />Ti MAXBOLTS 6 - O.G. E <br />E X B L 0 <br />12" FROM ANY CORNER <br />WINDOW OR DOOR OPENING <br />LOCATIONS <br />M <br />N <br />i� <br />II <br />II <br />III <br />III <br />III <br />III <br />II <br />II <br />II <br />I I I I I j <br />I I I I I I <br />I I I I I <br />II I <br />I�� I I ��� I I �� �♦ I <br />I <br />LJ I <br />L --- L r - - <br />if 11 I I a <br />\\ <br />1 <br />- - - - - - - - - - L - <br />-- --7 --- _ -- - i �N, <br />, r --� r- I I <br />II IL- I I <br />I I L------------------ <br />of <br />I 1 <br />II II III II <br />I L - - - J I III II <br />II II II illfl <br />II II II <br />I I 11 LJ- , ■ f <br />I I II I <br />■ <br />PLAN <br />SECTION R31S <br />PROTECTION AGAINST TERMITES <br />R318.1 Termite Protection. Termite protection shall be provided by registered tan Iticides, Including soil applied <br />R318.4 Concrete bearing ledge_ Brick, atone or other veneer shall be supported by a concrete bearing ledge <br />at least equal to the total thickness of the bridt stone or other veneer which Is poured Integrally with the <br />pesticides, batting systems, and pesticides applied to wood, or other approved methods of termite protection <br />labeled for use as a preventative treatment to new constructlom See Section 202, REGISTERED TErd11TICIOE. <br />concrete foundation. No supplemental concrete foundation pours which will create a hidden cold Joint shall be <br />Upon completion of the application of the termite protective treatment, a Certificate of Compliance shall be <br />used without supplemental treatment In the foundatton unless there Is an approved physical barrier. An <br />approved physical barrier shall also be installed from below the wall sill plate or first block course horizontally <br />Issued to the building department by the licensed peat control company that contains the following <br />statement: The building has received a complete treatment for the prevention of subterranean <br />to embed to a mortar Joint. IF masonry veneer extends below grade, a termite protective treatment must be <br />, <br />termites_ Treatment is In accordance with rules and laws established by the Florida Department of Agriculture and <br />applied to the cavity created between the veneer and the foundation, to lieu of a physical barrier. <br />Consumer Services- <br />Exception: veneer supported by a structural member secured to the foundation sidewall to accordance with ACI <br />R318-IJ If soil treatment is used For subterranean termite prevention, the initial chemical Boil treatment Inside the <br />Ix <br />530/ASCE 5/17,18 402, provided at least a 6 inch (152 mm) clear inspection space of the Foundation sidewall <br />exterior exists between the veneer and the top of any soil, sod, mulch or other organic landscaping component, <br />foundation perimeter shall be done after all excavation, badkFilitng and compaction is complete- <br />dedk, apron, porch, walk or any other work immediately adjacent to or adjoining the structure, <br />R318.12 If soil treatment is used For subterranean termite prevention, soil area disturbed after Initial chemical soil <br />treatment shall be retreated with a chemical soil treatment, including spaces boxed or formed. <br />R3185 Protection against decay and termites. Condensate lines, Irrigation/sprinkler system risers for spray heads, <br />and roof downspouts shall discharge at least I Foot (305 mm) away From the structure stdewall, whether by <br />R318.13 If soil treatment to used for subterranean termite prevention, space to concrete floors boxed out or <br />p p <br />underground piping, tall extensions or splash blocks. Gutters with downspouts are required on all buildings with <br />eaves of less than 6 Inches (152 mm) horizontal projection except For gable and rakes or on a roof above <br />formed for the subsequent installation of plumbing traps, drains or any other purpose shall be created by using <br />another roof_ <br />plastic or metal permanently placed forms of sufficient depth to eliminate any planned soil disturbance after <br />Initial chemical soil treatment <br />R31" Preparation of building site and removal of debris. <br />R31514 If soil treatment Is used for subterranean termite prevention, chemically treated soil shall be otected with <br />R318b_I All building sites shall be graded to provide drainage under all portions of the building not occupied <br />a minimum C. mil vapor retarder to protect against rainfall dilution. If rainfall occurs before vapor retarder <br />by basements. <br />placement, retrastment is required_ Any work, including placement or reinforcing steel, one after chemical <br />treatment until the concrete floor is poured, shall be done In such manner as to avoid penetrating or disturbing <br />R318b.2 The foundation and the area encompassed within i Foot (305 mm) therein shall have all vegetation, <br />treated soil. <br />Stumps, dead roots, cardboard, trash and Foreign material removed and the fill material shall be free of <br />R31815 If soil treatment to used For subterranean termite prevention, concrete overpour or mortar accumulated <br />vegetation and foreign material. The fill shall be compacted to assure adequate support of the Foundatiom <br />along the exterior foundation perimeter shall be removed prior to exterior chemical soil treatment to enhance <br />R318b3 After all work is completed, loose wood and debris shall be completely removed from under the <br />vertical penetration of the chemicals. <br />building and within I foot (305 mm) thereof_ Ali wood forma and supports shall be completely removed. This <br />t prevention, chemical soil treatments shall also be <br />R318-Ib If soil treatment to used for subterranean tie arm pr <br />includes but is not limited to: wooden grade stakes forms contractions spacers, tub trap boxes plumbing <br />9 P p p n9 <br />supports, bracing, shoring, Forms or other cellulose -containing material placed to any location where each <br />applied under all exterior concrete or grade within I foot (305 mm) of the primary structure sidewalls. Also, a <br />materials are not clearly visible and readily removable prior to completion of the work. Wood shall not be <br />vertical chemical barrier shall be applied promptly after construction is completed, Including initial landscaping <br />stored in contact with the ground under any building. <br />and irrigation/sprinkler installation. Any soil disturbed after the clinical vertical barrier is applied shall be <br />promptly retreated. <br />R318.1 Inspection for termites. In order to provide for inspection for termite Infestation, clearance between <br />R318-1.1 If a registered Lermiticide formulated and registered as a bait system Is used for subterranean termite <br />1(5) wall coverings and final earth grade on the exterior of a building shall not be less than 6 Inches <br />prevention, Section R318-1-1 through Section R31&1.6 do not applys however, a signed contract assuring the <br />installation, maintenance and monitoring of the batting system that ie in compliance with the requirements of <br />Exceptions: <br />Chapter 482, Florida Statutes, shall be provided to the building official prior to the pouring of the slab, and <br />the system must be installed prior to final building approval. If the baiting system directions for use require a <br />L paint or decorative cementittous finlsh less than 5/8 Inch (I-IJ mm) thick adhered directly to the masonry <br />foundation stdewalL <br />monitoring phase prior to installation of the pesticide active ingredient, the installation of the monitoring phase <br />2. Access or vehicle ramps which rise to the interior finish floor elevation for the width of such rams <br />components shall be deemed to constitute installation of the system. <br />on <br />A <br />R31818 If a registered termittetde formulated and Catered as a wood treatment Is used for subterranean <br />ag registered <br />3. 4-Inch (102 mm) inspection space above patio and garage slabs and entry areas. <br />4_ If the patio has been soil treated for termites, the finish elevation may match the building Interior finish <br />termite prevention, Sections R318.1.1 through R31816 do not apply. Application of the wood treatment termiticide <br />floor elevations on masonry construction only. <br />shall be as required by label directions for use, and must be completed prior to final building approval <br />5. Masonry veneers constructed In accordance with Sactlon R318.4. <br />R3182 Penetration Protective sleeves around piping penetrating concrete slab -on -grade floors shall not be <br />R318J3 Foam plastic protection In areas where the probability of termite infestation to very heavy, as Indicated <br />of cellulosecontatning materials. If soil treatment is wad far subterranean termite protection, the sleeve shall <br />have a maximum wall thickness of 0.010 inch (025 mm), and be sealed within the slab using a noncorrosive <br />to Figure R3012(6), extruded and expanded polystyrene, polytsocyanurate and other foam plastics shall not be <br />installed on the exterior Face or under interior or exterior foundation walls or slab Foundations located below <br />claming device to eliminate the annular space between the pipe and the sleave. No termittcides shall be <br />grade. The clearance between foam plastics installed above grade and exposed earth shall ba at least 6 <br />applied inside the sleeve. <br />inches (152 mm). <br />R3183 Cleaning_ Cells and cavities to masonry units and air gaps between brick, stone or masonry veneers and the <br />Exceptions: <br />structure shall be cleaned of all nonpreservative-treated or nonnaturally durable wood, or other <br />1. Buildings where the structural members of walls, floors, callings and roofs are entirely of noncombustible <br />cellulose -containing material prior to concrete placement. <br />materials or pressure -preservative -treated wood. <br />Exception: Inorganic material manufactured for closing cells in Foundation concrete masonry ant construction or <br />t 9 ng onry <br />2. When In addition to the requirements of Section R318.1, an approved method of protecting the foam <br />plastic and structure From subterranean termite damage is used <br />clean earth fill placed In concrete masonry unit voids below slab level before termite treatment Is performed <br />3. On the interior side of basement walls. <br />SECTION 1907 <br />MINIMUM SLAB PROVISIONS <br />1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less <br />than 3 1/2 inches (89 mm). A 6-mil (0.006 inch; 0.15 mm) polyethylene vapor retarder with joints lopped not <br />less than 6 inches (152 mm) shall be placed between the base course or subgrade and the concrete floor <br />slab, or other approved equivalent methods or materials shall be used to retard vapor transmission through <br />the floor slab. <br />Exception: A vapor retarder is not required: <br />1. For detached structures accessory to occupancies in Group R-3, such as garages, utility buildings or <br />other unheated facilities. <br />2. For unheated storage rooms having on area of less than 70 square feet (6.5 m2) and carports attached to <br />occupancies in Group R-3. <br />3. For buildings of other occupancies where migration of moisture through the slab from below will not be <br />detrimental to the intended occupancy of the building. <br />4. For driveways, walks, patios and other flatwork which will not be enclosed at a later date. <br />5. Where approved based on local site conditions. <br />ELACTR I C,4L NOTES <br />ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES SUCH AS THE NATIONAL <br />ELECTRICAL CODE 2014, LOCAL ORDINANCES AND POWER COMPANY REGULATIONS. <br />SUBCONTRACTOR SHALL BE LICENSED, CARRYALL APPLICABLE.INSURANCE, AND HAVE A CURRENT COUNTY <br />OCCUPATIONAL LICENSE. AS ALLOWED, CONNECT ADDITIONAL ELECTRICAL TO EXISTING CIRCUITS_ <br />SUBCONTRACTORS SHALL INCLUDE ALL SPECIAL FEES AND PERMITS,. LABOR AND MATERIAL, EQUIPMENT AND <br />ELECTRICAL ENGINEERING NECESSARY TO PROVIDE AN APPROVED WORKING SYSTEM. LIGHT FIXTURES EXCLUDED <br />EXCEPT FOR FLUORESCENT FIXTURES AND RECESSED LIGHTS. <br />CONCRETE -ENCASED ELECTRODE. AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WiTHIN <br />AND NEAR THE BOTTOM OF THE CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE <br />EARTH, CONSISTING OF AT LEAST 20 FT_ OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICITY <br />CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH DIAMETER, OR CONSISTING <br />OF AT LEAST 20 FEET OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4 AWG. REINFORCING BARS SHALL BE <br />PERMITTED TO BE BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER EFFECTIVE MEANS." <br />210.12 ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION_ <br />(A) DEFINITION: ARC -FAULT CIRCUIT INTERRUPTER (AFCi). A DEVICE INTENDED TO PROVIDE PROTECTION FROM <br />THE EFFECTS OF ARC FAULTS BY RECOGNIZING CHARACTERISTICS UNIQUE TO ARCING AND BY FUNCTIONING TO <br />DE -ENERGIZE THE CIRCUIT WHEN AN ARC FAULT IS DETECTED. <br />(B) DWELLING UNITS. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, <br />BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND OTHER SPECIFIED ROOMS OR AREAS <br />SHALL BE <br />PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE <br />PROTECTION OF THE BRANCH CIRCUIT_ <br />CARBON MONOXIDE ALARMS <br />R315.1 CARBON MONOXIDE PROTECTION. EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING BUILDING FOR <br />WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED AND HAVING A FOSSIL -FUEL -BURNING HEATER OR APPLIANCE, A <br />FIREPLACE, AN ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE AS A <br />BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET <br />(3048 mm) OF EACH ROOM USED FOR SLEEPING PURPOSES_ <br />EXCEPTION: THIS SECTION SHALL NOT APPLY TO EXISTING BUILDINGS THAT ARE UNDERGOING ALTERATIONS OR <br />REPAIR UNLESS THE ALTERATION IS AN ADDITION AS DEFINED IN SECTION R315.13. <br />R315.1.1 CARBON MONOXIDE ALARM. THE REQUIREMENTS OF SECTION R315.1 SHALL BE SATISFIED BY PROVIDING FOR <br />ONE OF THE FOLLOWING ALARM INSTALLATIONS: <br />(1) A HARD -WIRED CARBON MONOXIDE ALARM. <br />(2) A BATTERY -POWERED CARBON MONOXIDE ALARM_ <br />(3) AHARD-WIRED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />(4) A BATTERY -POWERED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />R315.1.2 COMBINATION ALARMS. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED AND LABELED <br />BY A NATIONALLY RECOGNIZED TESTING LABORATORY. <br />R315.13 ADDITION SHALL MEAN: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A <br />BUILDING OR STRUCTURE <br />INTERIOR ELECTR i C,4L OUTLET LOC4T i ONS <br />PADDLE FAN SWITCH <br />(LOCATE OVER FAN <br />LIGHT SWITCH) <br />LIGHT SWITCH <br />DUPLEX OUTLET AT <br />KITCHEN COUNTER, REFRIG., <br />° WASHER AND GARAGE OUTLETS <br />DUPLEX OUTLET AT <br />VANITY COUNTER <br />STANDARD <br />DUPLEX OUTLET <br />B <br />o <br />N <br />ELECTRICAL S�M15OLS LEGEND <br />CEILING LIGHT <br />{R} RECESSED CAN LIGHT <br />4- <br />0 11OV DUPLEX RECEPTACLE <br />S 22OV OUTLET <br />rfsP.I. <br />® 11OV G.F.I. OUTLET <br />SWITCHED DUPLEX REC_ <br />® OUTLET (HWH, AH, ETC.) <br />$ SINGLE POLE SWITCH <br />THREE WAY LIGHT SWITCH <br />Vy GARAGE DOOR OPENER <br />m 200 AMP. PANEL <br />%r-------- SHOP FLUORESCENT <br />--------- LIGHT <br />Z X 4' FLUORESCENT <br />LIGHT <br />_-�_- TRACK LIGHTING <br />aaQoao•O'ao'o'atT <br />BEAUTY BAR LIGHT <br />BRACE d <br />PRE -WIRE <br />FOR FAN <br />® TELEVISION PRE -WIRE <br />TELEPHONE PRE -WIRE <br />Q <br />SMOKE ALARM <br />® <br />CARBON MONOXIDE <br />DETECTOR <br />O <br />JUNCTION BOX <br />4 <br />PUSH BUTTON (GAD-O_, <br />CHIMES, ETC.) <br />FLOOD LiGHT <br />® <br />DOOR BELL CHIME <br />ELECTRICAL WIRING <br />LEXHAUST <br />FAN <br />LIGHT/EX. FAN <br />U <br />C <br />Q <br />O <br />L <br />CD <br />C <br />U) <br />O <br />0 <br />(ll <br />C <br />O <br />Cn <br />N <br />C <br />O <br />U <br />O <br />CV <br />O <br />CV <br />F- <br />C� <br />CL' <br />CL <br />O <br />U <br />