R502.5 Allowable girder spans. <br />The allowable spans of girders fabricated of dimension lumber shall not <br />exceed the values set forth in Tables R502. 5( 1) and R502. 5(2). <br />TABLE R502. 5( 1) <br />GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS <br />(Maximum spans for Douglas fir -larch, hem -fir, southern pine <br />and spruce-pine-firb and required number of jack studs) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />NJd <br />SPAN <br />NJd <br />SPAN <br />NJd <br />Roof and ceiling <br />2-2x4 <br />3-6 <br />1 <br />3-2 <br />1 <br />2-10 <br />1 <br />2-2x6 <br />5-5 <br />1 <br />4-8 <br />1 <br />4-2 <br />1 <br />2-2x8 <br />6-10 <br />1 <br />5-11 <br />2 <br />5-4 <br />2 <br />2-2x10 <br />8-5 <br />2 <br />7-3 <br />2 <br />6-6 <br />2 <br />2-2x12 <br />9-9 <br />2 <br />8-5 <br />2 <br />7-6 <br />2 <br />3-2x8 <br />8-4 <br />1 <br />7-5 <br />1 <br />6-8 <br />1 <br />3-2x10 <br />10-6 <br />1 <br />9-1 <br />2 <br />8-2 <br />2 <br />3-2x12 <br />12-2 <br />2 <br />10-7 <br />2 <br />9-5 <br />2 <br />4-2x8 <br />9-2 <br />1 <br />8-4 <br />1 <br />7-8 <br />2 <br />4-2x10 <br />11-8 <br />1 <br />10-6 <br />1 <br />9-5 <br />1 2 <br />4-2x12 <br />14-1 <br />1 <br />12-2 <br />2 <br />10-11 <br />2 <br />Roof, ceiling and one <br />center -bearing floor <br />2-2x4 <br />3-1 <br />1 <br />2-9 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />4-0 <br />1 <br />3-7 <br />2 <br />2-2x8 <br />5-9 <br />2 <br />5-0 <br />2 <br />4-6 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />2-2x12 <br />8-1 <br />2 <br />7-1 <br />2 <br />6-5 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />2 <br />5-8 <br />2 <br />3-2x10 <br />8-9 <br />2 <br />7-8 <br />2 <br />6-11 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-11 <br />2 <br />8-0 <br />2 <br />4-2x8 <br />8-1 <br />1 <br />7-3 <br />1 <br />6-7 <br />2 <br />4-2x10 <br />10-1 <br />1 <br />8-10 <br />2 <br />8-0 <br />2 <br />4-2x12 <br />11-9 <br />2 <br />10-3 <br />2 <br />9-3 <br />2 <br />Roof, ceiling and one <br />clear span floor <br />2-2x4 <br />2-8 <br />1 1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-11 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x8 <br />5-0 <br />2 <br />4-2 <br />3 <br />3-9 <br />2 <br />2-2x10 <br />6-1 <br />2 <br />5-1 <br />3 <br />4-7 <br />3 <br />2-2x12 <br />7-1 <br />3 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />6-3 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-7 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-10 <br />2 <br />7-4 <br />3 <br />6-7 <br />2 <br />4-2x8 <br />7-2 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x10 <br />8-9 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x12 <br />10-2 <br />2 <br />8-6 <br />2 <br />7-8 <br />2 <br />Roof, ceiling and two <br />center -bearing floors <br />2-2x4 <br />2-7 <br />1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-9 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x8 <br />4-9 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />2-2x10 <br />5-9 <br />2 <br />5-1 <br />2 <br />4-7 <br />3 <br />2-2x12 <br />6-8 <br />2 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />5-11 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-3 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-5 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x8 <br />6-10 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x10 <br />8-4 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x12 <br />9-8 <br />2 <br />8-6 <br />2 <br />7-8 <br />2 <br />Roof, ceiling and two <br />clear span floor <br />2-2x4 <br />2-1 <br />1 <br />1-8 <br />1 <br />1-6 <br />2 <br />2-2x6 <br />3-1 <br />2 <br />2-8 <br />2 <br />2-4 <br />2 <br />2-2x8 <br />3-10 <br />2 <br />3-4 <br />2 <br />3-0 <br />3 <br />2-2x10 <br />4-9 <br />2 <br />4-1 <br />3 <br />3-8 <br />3 <br />2-2x12 <br />5-6 <br />2 <br />4-9 <br />3 <br />4-3 <br />3 <br />3-2x8 <br />4-10 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />3-2x10 <br />5-11 <br />2 <br />5-1 <br />2 <br />4-7 <br />2 <br />3-2x12 <br />6-10 <br />1 2 <br />5-11 <br />3 <br />5-4 <br />2 <br />4-2x8 <br />5-7 <br />2 <br />4-10 <br />2 <br />4-4 <br />2 <br />4-2x10 <br />6-10 <br />2 <br />5-11 <br />2 <br />5-3 <br />2 <br />4 2x12 <br />7 11 <br />2 <br />6 10 <br />2 <br />6 2 <br />3 <br />TABLE R602. 7(2) <br />GIRDER SPANSaAND HEADER SPANSa FOR INTERIOR BEARING WALLS <br />(MAXIMUM SPANS FOR DOTGLAS FIR -LARCH, HEM -FIR, SOUTHERN PINE <br />AND SPRUCE -PINE -FIR AND REQUIRED NUMBER OF JACK STUDS) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />NJ <br />SPAN <br />NJd <br />SPAN <br />NJd <br />One floor only <br />2-2x 4 <br />3-1 <br />1 <br />2-8 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />3-11 <br />1 <br />3-6 <br />1 <br />2-2x8 <br />5-9 <br />1 <br />5-0 <br />2 <br />4-5 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-1 <br />2 <br />5-5 <br />2 <br />2-2x12 <br />8-1 <br />2 <br />7-0 <br />2 <br />6-3 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />1 <br />5-7 <br />2 <br />3-2x10 <br />8-9 <br />1 <br />7-7 <br />2 <br />6-9 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-10 <br />2 <br />7-10 <br />2 <br />4-2x8 <br />9-0 <br />1 <br />7-8 <br />1 <br />6-9 <br />2 <br />4-2x10 <br />10-1 <br />1 <br />8-9 <br />1 <br />7-10 <br />2 <br />4-2x12 <br />11-9 <br />1 <br />10-2 <br />2 <br />9-1 <br />2 <br />Two floors <br />2-2x4 <br />2-2 <br />1 <br />1-10 <br />1 <br />1-7 <br />1 <br />2-2x6 <br />3-2 <br />2 <br />2-9 <br />2 <br />2-5 <br />2 <br />2-2x8 <br />4-1 <br />2 <br />3-6 <br />2 <br />3-2 <br />2 <br />2-2x10 <br />4-11 <br />2 <br />4-3 <br />2 <br />3-10 <br />3 <br />2-2x12 <br />5-9 <br />2 <br />5-0 <br />3 <br />4-5 <br />3 <br />3-2x8 <br />5-1 <br />2 <br />4-5 <br />2 <br />3-11 <br />2 <br />3-2x10 <br />6-2 <br />2 <br />5-4 <br />2 <br />4-10 <br />2 <br />3-2x12 <br />7-2 <br />2 <br />6-3 <br />2 <br />5-7 <br />3 <br />4-2x8 <br />4-2 <br />2 <br />5-3 <br />2 <br />4-8 <br />2 <br />4-2x10 <br />7-2 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />4-2xl2 <br />8-4 <br />2 <br />7-2 <br />2 <br />6-5 <br />2 <br />For S1: 1 inch = 25.4 mm, 1 foot=304.8mm <br />a. Spans are given in feet and inches. <br />b. Tabulated values assume #2 grade lumber. <br />c. Building width is measured perpendicular to the ridge. For widths between <br />those shown, spans are permitted to be interpolated. <br />d. NJ - Number of jack studs required to support each end. Where the number of <br />required jack studs equals one, the header is permitted to be supported by an <br />approved framing anchor attached to the full -height wall stud and to the <br />header. <br />R502.2.6 Bearing. The ends of each joist, beam or girder shall have not less than 1.5 inches (38 mm) <br />of bearing on wood or metal and not less than 3 inches (76 mm) on masonry or concrete except where <br />supported on a 1-inch-by-4-inch (25.4 mm by 102 mum) ribbon strip and nailed to the adjacent stud or <br />by the use of approved joist hangers. <br />R502.2.6. 1 Floor systems [ IRC R502. 6. 1]. Joists framing from opposite sides over a bearing support <br />shall lap a minimum of 3 inches (76 mm) and shall be nailed together with a minimum three lad face <br />nails. Atwood or metal splice with strength equal to or greater than that provided by the nailed lap <br />is permitted. <br />R502.2.6.2 Joist framing [IRC R502.6.2]. Joists framing into the side of a wood girder shall be <br />supported by approved framing anchors or on ledger strips not less than nominal 2 inches by 2 inches <br />(51 mm by 51 mm). <br />R502-2-7 Lateral restraint at supports [IRC R502.7]. Joists shall be supported laterally at the ends <br />by full -depth solid blocking not less than 2 inches (51 mm) nominal in thickness; or by attachment to <br />a full -depth header, band, or rim joist, or to an adjoining stud; or shall be otherwise provided with <br />lateral support to prevent rotation. <br />Exception: Reserved. <br />R502.2.7. I Bridging [IRC R502.7. 1]. Joists exceeding a nominal 2 inches by 12 inches (51 mm by 305 mum) <br />shall be supported laterally by solid blocking, diagonal bridging (wood or metal), or a continuous <br />1-inch-by-3-inch (25.4 mm by 76 mm) strip nailed across the bottom of joists perpendicular to joists <br />at intervals not exceeding 8 feet (2438 mm). <br />R502.2.8 Drilling and notching [IRC R502.8]. Structural floor members shall not be cut, bored or <br />notched in excess of the limitations specified in this section_ See Figure R502.2.8. <br />R502.2.8.1 Sawn lumber[IRC R502.8.1]. Notches in solid lumber joists, rafters and beams shall not <br />exceed one -sixth of the depth of the member, shall not be longer than one-third of the depth of the <br />member and shall not be located in the middle one-third of the span. Notches at the ends of the member <br />shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or <br />greater in nominal thickness shall not be notched except at the ends of the members. The diameter of <br />holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be <br />closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the <br />member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the <br />notch. <br />R502.2.8.2 Engineered wood products [IRC R502.8.2]. Cuts, notches and holes bored in trusses, <br />structural composite lumber, structural glue -laminated members or I -joists are prohibited except where <br />permitted by the manufacturer's recommendations or where the effects of such alterations are <br />s ec"ficall considered i the desi n of the member b a re istered desi n rofessional <br />ROOF SHEATHING: FASTENING= SCHEDULE ahcd,e <br />ad Common (0.131 x 2-1/2 inches) or Ring -Shank (0.135 X 2-1/2 inches) <br />(Except LLkiere Noted) for Exposure B, Enclosed Buildings, Roof Framing Spaced 24 inches <br />oc. or Less <br />Roof Fastening Zone <br />Overhang <br />Wind <br />Main <br />Sheathing -to -Gable <br />(eaves) <br />velocity <br />Roof <br />End -Wall Framingg <br />(3-Second <br />Panel <br />1 <br />2 <br />3 2 3 <br />2 <br />3 <br />Crust) <br />Location <br />Fastening Schedule Cinches on center) <br />Supported Panel <br />fo <br />6 <br />6 <br />6 <br />6 <br />150 mph fg <br />end and edges <br />3h <br />Panel field <br />ro <br />4 <br />3 <br />4 <br />3 <br />f g <br />Supported Panel <br />6 <br />6 <br />6 <br />6 <br />6 <br />120 mph <br />end and edges <br />3 <br />Panel field <br />12 <br />6 <br />4 <br />6 <br />4 <br />,Supported Panel <br />6 <br />6 <br />6 <br />6 <br />6 <br />90 mph <br />end and edges <br />6 <br />Panel field <br />12 <br />12 <br />6 <br />6 <br />6 <br />a. Specific gravity (G) of lumber and panels shall be 0.42 or greater. <br />b. For Exposure 5 and a 2-foot overhang. <br />C. For median roof height 35 feet or less. <br />d. Gable wall height of 8 feet or less from top floor ceiling to roof peak. <br />e. Provide adequate uplift hardware at truss -to -wall connections. Such <br />connections are beyond the scope of this publication. <br />F. When wind speed is 110 mph or greater and when median roof height is between <br />25 and 35 feet, use 8d ring shank nails (0.135 x 2-1/2 incheshuithin 48 inches of <br />gable and walls. (iRC Table R6023, footnote f) <br />g. When wind speed is 100 mph or greater, block panel edges perpendicular to <br />gable -end -wall framing members in the first two bays of framing. 5locking shall be <br />spaced a maximum of 4 feet o_c. (Wood Frame Construction Manual, Section 3BB) <br />h. 10d ring -shank nails (0.148x 3 inches). <br />i. 5locking not required. <br />ROOF FASTENING ZONES FOR WIND UPLIFT <br />Zones 1,2 and 3 shown below indicate areas of the roof that may have different fastening <br />requirements. <br />GABLE END WALL <br />3 OVERHANG � <br />�3 OVERHANG LL LINE d 3 OVERHANG \ WALL LINE 1 GABLE END WALL <br />Distance a=4 ft. in most cases (10% of least building width or 0.4 times building height, <br />whichever is smaller, but not less than either 4% of least building width or 3 ft.) <br />ROOF 1 IAPHRAM SAILING SCHEDULE (GAPLOS) <br />p i y n 9 y 9 9 P COLLAR TIE 1X& (MIN.) E\/EP,f <br />R502.2.9 Fastening [IRC R502.9]. Floor framing shall be nailed in accordance with Table R602.2(1) m <br />Wh t d b ' d +ruction is used to s art floor fromin ositive connections OTHER RAFTER 1-,a OR LONGER <br />- - - <br />- <br />ere pos s an eam or g>r er cons upp 9, p <br />shall be provided to ensure against uplift and lateral displacement. <br />For SI: 1 inch = <br />25.4 mm, 1 pound per square foot = 0.0479 <br />kN/m2. <br />R502.2.10 Framing of openings [IRC R502.10]. Openings in floor framing shall be framed with a header <br />a. Spans are given <br />in feet and inches. <br />and trimmer joists. When the header joist span does not exceed 4 feet (1219 mm), the header joist may <br />b. Tabulated values <br />assume #2 grade lumber. <br />be a single member the some size as the floor joist. Single trimmer joists may be used to carry a <br />c. Building width is <br />measured perpendicular to the ridge. <br />For widths between <br />single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. <br />those shown, spans <br />are permitted to be interpolated. <br />When the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be <br />d. NJ - Number of jack <br />studs required to support each end. <br />Where the number of <br />doubled and of sufficient cross section to support the floor joists framing into the header. Approved <br />required jack studs <br />equals one, the header is permitted to <br />be supported <br />hangers shall be used for the header joist to trimmer joist connections when the header joist span <br />by an approved framing <br />anchor attached to the full -height <br />wall stud and to the <br />exceeds 6 feet (1829 mm). Tail joists over 12 feet (3658 mm) long shall be supported at the header by <br />header. <br />framing anchors or on ledger strips not less than 2 inches by 2 inches (51 mm by 51 mm). <br />e. Reserved. <br />R502.3 Design and construction where wind speed is 100 mph or greater. Floor framing of light -frame <br />wood construction shall be designed and constructed in accordance with the provisions of Section <br />24" MIN. LAP <br />R301.2. 1. 1, Section R502. 1. <br />PIL,45TER <br />21_0„ O <br />MAX. <br />rFs <br />#3 OR #4 REINFORCING BAR <br />II 11 <br />moD�Q���o.minc)onooinOOm <br />- <br />25" MiN. LAP <br />--*5 REINFORCING BAR <br /># Lo4i= SPLICE <br />3�" MIN I AP <br />"', 1,I=11'r_L T L,IIVC3 17HM <br />#6 L.Af= E)f'L i C <br />42" MIN- LAP <br />#7 L4f= ef=L i C <br />1n" <br />05 REINFORCING BAR <br />ART i CAL <br />�C�I�I�L 1„I1��ONRY <br />S' PLATE HEIGHT = 0'-0" O.G. <br />10' PLATE HEIGHT = &'-0" O_C. <br />12' PLATE HEIGHT = 4'-0" O.C. <br />"A" 14' PLATE HEIGHT = 2'-0" O_C. MAX. / PILASTERS Q 10'-0" O.G. <br />AT EACH CORNER 4 BOTH SIDES OF DOORS 8 WINDOWS OPENINGS <br />(OVER 5'-0"). BEFORE 4 AFTER 5HEARWALL SEGMENTS, 8 <br />(2) BARS 6 EA. SIDE OF OPENING OVER 12'-0" <br />R LAP DIST <br />BLOCKING BELOW RIIDGE <br />2Xro VERTICAL SCAB OR KNEEWALL MiD-POINT <br />iN RAFTER UJ/ RAFTER SPAN LENGTH GREATER <br />THAN 14 FT OR LONGER <br />CONN W1 4-10d NAILS AT TOP 4 HURRICANE <br />CLIP 0 BOTTOM. <br />2X(o (MIN-) NO. 2 l'P VALLEY FRAMINGSIMP50N LSTA12 <br />(Of(TYP. SIM EQUAL) <br />2X8 NO. 2 5PF PLYWOOD SHEATHING <br />RIDGE BOARD <br />=ff 0_1467L F-AMUT <br />F-E--- 25" MIN. LAP <br />U <br />d <br />Q -- Fr-- - <br />IICM.U. WALL <br />'I (1) 05 DOWEL <br />II I IN CORNER <br />(4) 106 Q RIDGE <br />BOARD END <br />TRUSSES BELOW SHEATHED PRIOR <br />TO VALLET' FRAMING INSTALLATION <br />OR 6'-0" O_C_ TOP CHORD <br />SIMPSON L6TA12 STRAP OR SiMPSON A22 TiE <br />EA_ RAFTER UJ/ 10-106 NAILS <br />(T T PJ <br />2X(o CONT. W/SLEEPER, CLIPPED <br />OR STRAPPED TO TRUSS BELOW <br />Y FRAMING: DETAI <br />25" MiN. LAP <br />I • <br />I <br />II (1) *5 DOWEL <br />II IN CORNER <br />CORNER CONT IN i TY 4 LUALL RE iNFFORISVIENT FOOTING 4 STErvILJALL RE iNFORCE"ENT <br />TABLE 2304. 10. 1 <br />FASTENING SCHEDULE <br />DESCRIPTION OF BUILDING ELEMENTS <br />NUMBER AND TYPE OF FASTENER <br />SPACING <br />AND LOCATION <br />Roof <br />3-8d common 2 x 0. 131, ; or <br />3-10d box (3" x 0. 128, ); or <br />1. <br />Blocking between ceiling joists, rafters or trusses to top <br />3-3" x 0.131" nails; or <br />Each end, toenail <br />plate <br />or other framing below <br />3-3" 14 gage staples, crown <br />2-8d common (2j" X 0. 131") <br />2-3" x 0.131" nails <br />Each end, toenail <br />Blocking <br />between rafters or truss not at the wall top plate, <br />2-3" 14 gage staples <br />to <br />rafter or truss <br />2-16 d common (3" x 0.162") <br />3-3" x 0.131" nails <br />End nail <br />3-3" 14 gage staples <br />16d common (3j" X 0. 162") @ 6" o. c. <br />3"x 0.131" nails @ 6" o. c. <br />Face nail <br />Flat <br />blocking to truss and web filler <br />3" 14 gage staples @ 6"o.c. <br />3-8d common (2j" X 0.131")or <br />3-10d box (3" x 0.128")or <br />Each joist, toenail <br />2. <br />Ceiling joists to top plate <br />3-3" 0.131" nails; or <br />3-3" 14 goge staples, " crown <br />3. <br />Ceiling joist not attached to parallel rafter, <br />3-16d common (2J" X 0.131")or <br />4-10d box (3" x 0.128")or <br />Each toenail <br />laps <br />over partitions (no thrust) <br />end, <br />(see <br />Section 2308.7.3.1, Table 2308.7.3.1) <br />4-3"x 0.131" nails; or <br />4-3" 14 gage staples, ?6" crown <br />4. <br />Ceiling joist attached to parallel rafter (heel joint) (see <br />per Table 2308.7.3.1 <br />Face nail <br />Section <br />2308.7.3.1, Table 2308.7.3.1) Per Table 2308.7.3.1 <br />3-10d common (3" X 0.148");or <br />4-10d box (3" x 0. 128"); or <br />5. <br />Collar tie to rafter <br />4-3' 0.131" nails; or <br />Face nail <br />4-3" 14 gage staples,?g" crown <br />3-10d common (3" X 0. 148") ; or <br />4-10d box (3" x 0. 128"); or <br />6. <br />Rafter or roof truss to top plate <br />4-3" 0.131" nails; or <br />Face nail <br />(See <br />Section 2308. 7.5, Table 2308. 7. 5) <br />4-3' 14 gage staples, ?g" crown <br />2-16d common (3 1/2" X 0. 162"); or <br />3-10d box (3" x 0. 128") ; or <br />3-3" 0.131" nails; or <br />3-3" 14 gage staples, ?g" crown; or <br />End nail <br />7. <br />Roof rafters to ridge valley or hip rafters; or roof <br />3-10d common (3 1/2" X 0.148");or <br />rafter <br />to 2-inch ridge beam <br />3-16d box (3 1/2" x 0.135");or <br />4-10d box (3"x 0128'); or <br />Toenail <br />4-3"x 0.131" nails; or <br />4-3" 14 qaqe staples, " crown <br />l6d common (3 1/2" X 0. 162" <br />24"o. c, face <br />nail <br />common 3 X 0. 128 ; or <br />8. <br />Stud to stud not at braced wall panels) <br />( P ) <br />3 x <br />3"x 0. 131" nails; or <br />16" a. c. face <br />nail <br />3-3" 14 gage staples, A" crown <br />16d common 3 1/2" X 0. 162"); <br />16"o. c. face <br />nail <br />9. <br />Stud to stud and abutting studs at intersecting wall <br />16d box 3 1/2" X 0.135" ;or <br />12"o.c. face <br />nail <br />3"x 0.131 nails; or <br />corners (at braced wall panels) <br />3-3" 14 gage staples, ?g" crown <br />12"o.c. face <br />nail <br />10. <br />Built-up header (2" to 2" header)) <br />16d common (3 1/2" X 0.162" <br />16"o.c. face <br />nail <br />16d box 3 1/2" X 0. 135" ; or <br />12"o. c. face <br />nail <br />11. <br />Continuous header to stud 4--8d common (21/2, X 0. 131� ); <br />4-8d common (2 1/2" X 0. 131"); or <br />Toenail <br />4-10d box (3" X 0. 128" <br />S6d common 3 1 2" X 0. 162" ; or <br />16"o. c. face <br />nail <br />lOd conmon 3 X 0. 128 ; or <br />12. <br />Top plate to top plate <br />3"x O. 131" nails; or <br />12"o. c. face <br />nail <br />3" 14 gage staples, ?g" crown <br />8-16d common (3 1/2" X 0.162");or <br />Each side of <br />end joint, face <br />12-10d box (3" x 0.128");or <br />nail <br />13. <br />Top plate to top plate, at end joints <br />12-3" 0.131' nails; or <br />(minimum 24" <br />lap splice length <br />12-3" 14 gage staples, ?g" crown <br />each side of <br />end joint) <br />I6d common (3 1 2" X 0. 162"); or <br />16"0. c. face <br />nail <br />14. <br />Bottom plate to joist, rim joist, band joist or blocking <br />16d box 3 1 2 X 0.135 ;or <br />(not <br />at braced wall panels) <br />3"x 0.131" nails; or <br />12"o.c. face <br />nail <br />3" 14 gage staples, ?g" crown <br />2-I6d common (3 1/2" X 0. 162"); or <br />15. <br />Bottom plate to joist, rim joist, band joist or blocking <br />3-16d box (3 1/2" x 0.135");or <br />at <br />braced wall panels <br />4-3" 0.131" nails; or <br />Toenail <br />4-3" 14 gage staples,A" crown <br />4-8d common (2 1/2" X 0. 131"); or <br />4-10d box (3" x 0.128");or <br />Toenail <br />4-3" 0. 131" nails; or <br />4-3" 14 gage staples,&" crown <br />16. <br />Stud to top or bottom plate <br />2-16d common (3 1/2" X 0. 162"); or <br />3-10d box (3" x 0. 128") ; or <br />3-3" 0.131" nails; or <br />End nail <br />3-3" 14 gage staples, ?g" crown <br />2-I6d common (3 1/2" X 0. 162"); or <br />3-I0d box (3" x 0. 128"); or <br />17. <br />Top or bottom plate to stud <br />3-3" 0.131" nails; or <br />End nail <br />3-3" 14 gage staples, A" crown <br />2-16d common (3 1/2" X 0. 162"); or <br />3-10d box (3" x 0. 128"); or <br />18. <br />Top plates, laps at corners and intersections <br />3-3" 0.131" nails; or <br />Face nail <br />3-3" 14 gage staples, ?g" crown <br />2-8d common (2 1/2" X 0. 131"); or <br />2-10d box (3" x 0. 128"); or <br />19. <br />1" brace to each stud and plat <br />2-3" 0.131' nails; or <br />Face nail <br />3-3" 14 gage staples, �g" crown <br />2-8d common (2 1/2" X 0. 131"); or <br />20. <br />1"x6" sheathing to each bearing <br />3-10d box (3" x 0.128");or <br />Face nail <br />3-Sd common (2 10.1 X );or <br />21. <br />1"x8" and wider sheathingto each bearing <br />9 <br />3-lOd box (3" x 0. 128"); or <br />);or <br />Face nail <br />Floor <br />3-8d common (2 1/2" X 0. 131"); or <br />3-10d box (3" x 0. 128"); or <br />22. <br />Joist to sill, topplate, or girder <br />3-3" 0.131" nails; or <br />Toenail <br />3-3" 14 gage staples, &" crown <br />8d common (2 1/2" X 0. 131"); or <br />10d box (3" x 0. 128"); or <br />23. <br />Rim joist, band joist, or blocking to top plate, sill or <br />3" 0.131" nails; or <br />6"o.c., toenail <br />other <br />framing below <br />3" 14 gage staples, &" crown <br />2-8d common (2 1/2" X 0. 131'); or <br />24. <br />1"x 6"subfloor or less to each 'oist <br />2-10d box (3" x 0.128");or <br />Face nail <br />25. <br />2" subfloor to 'oist or girder <br />2-16d common 3 1/2" X 0.162" <br />Face nail <br />26. <br />2" planks lank & beam - floor & roof <br />2-16d common 3 1/2- X 0.162' <br />Each bearing, <br />face nail <br />32" a.c., face nail at top and <br />20d common (4'x 0.192") <br />bottom <br />staggered on <br />opposite sides) <br />10d common 3 X 0. 128 ; or <br />24" o. c., face nail at top and <br />27. <br />Built-up girders and beams, 2; lumber layers <br />3"x 0.131" nails; or <br />bottom <br />3" 14 gage staples, ?g" crown <br />staggered on <br />opposite sides) <br />2-20d common (4' X 0. 192") ; or <br />3-10d box (3" x 0.128");or <br />Ends and at each splice, face <br />3-3' 0.131" nails; or <br />nail <br />3-3" 14 gage staples,?g" crown <br />3-16d common (3 1/2" X 0. 162") ; or <br />4-10d box (3" x 0.128");or <br />Each joist or <br />rafter, face nail <br />28. <br />Ledger strip supporting joists or rafters <br />4-3' 0.131" nails; or <br />4-3" 14 gage staples,A" crown <br />3-16d common (3 1/2" X 0. 162"); or <br />4-10d box (3" x 0.128");or <br />End nail <br />29. <br />Joist to band joist or rim joist <br />4-3" 0.131" nails; or <br />4-3" 14 gage staples,A" crown <br />3-16d common (3 1/2" X 0. 162"); or <br />4-I0d box (3" x 0.128");or <br />End nail <br />30. <br />Bridging or blocking to joist, rafter or truss <br />4-3" 0.131" nails; or <br />4-3" 14 gage staples, ?g" crown <br />Wood structural panels (WSP), subfloor, roof and interior wall <br />sheathing to framing and particleboard <br />wall sheathing <br />to <br />framing <br />a <br />Edges <br />Intermediate <br />(inches) <br />supports <br />(inches) <br />6d common or deformed (2' x 0.113") <br />6 <br />12 <br />subfloor and wall <br />Sd box or deformed (2 1/2"x 0.113") <br />6 <br />12 <br />roof <br />2gJ"xO. 113" nail (subfloor and wall) <br />6 <br />12 <br />"- <br />31. <br />3/8 1/2" <br />1j" 16 gage staple, ?g' crown <br />4 <br />8 <br />subfloor and wall <br />2J" x 0.113, nail (roof) <br />4 <br />8 <br />1 3/4"16 gage staple,?g"crown(roof) <br />3 <br />6 <br />8d common (2 1/2"x 0. 131"); or <br />6 <br />12 <br />6d deformed 2"xO.113' <br />32. <br />19/32 " - 3/4' <br />21"xO.113, nail; or <br />6 <br />12 <br />2" 16 qGqe staple, 7 16 crown <br />10d common (3" x 0. 148") ; or <br />6 <br />12 <br />33. <br />7/8 " - 1J <br />8d deformed (2;"x 0. 131" <br />Other exterior wall sheathing <br />1j" galvanized roofing nail <br />(A" head diameter); or <br />34. <br />1/2 "fiberboard sheathing b <br />1j", I6 gage staple with fg"or 1' <br />crown <br />3 <br />6 <br />2-20d common (4" X 0. 192"); or <br />35. <br />25/32, fiberboard sheathing b <br />3-10d box (3" x );or <br />3 <br />6 <br />3-3" 0.131" nails;s; or or <br />3-3" 14 gage staples, ?g" crown <br />Wood structural panels, combination subfloor underlayment to framing <br />8d common (2 1/2"x 0. 131"); or <br />6 <br />12 <br />36. <br />3 4 "and less <br />6d deformed 2"xO. 113" <br />"- <br />8d common (2 1/2"x 0.131"); or <br />6 <br />12 <br />37. <br />7/8 1" <br />6d deformed 2"xO. 113" <br />38. <br />1h'- 1j" <br />lOd common ( 3' x 0. 148") ; or <br />6 <br />12 <br />8d deformed 2 1 2"xO.131" <br />Panel siding to <br />framing <br />6d corrosion -resistant siding <br />(1i" X 0.106");or <br />39. <br />1/2, or less <br />6d corrosion -resistant casing (2"X <br />6 <br />12 <br />0.099") <br />8d corrosion -resistant siding <br />40. <br />5/8" <br />(2 3/8" X 0. 128"); or <br />8d corrosion -resistant casing <br />6 <br />12 <br />(2 1/2"X 0.113") <br />Interior paneling <br />4d common (1 1/2"x 0.080"); or <br />6 <br />12 <br />41. <br />}" <br />4d finish 1 1 2"x 0.072" <br />42 <br />J" <br />6d casing (2"x 0. Ogg-); or <br />6 <br />12 <br />6d finish Panel supports at 24" <br />For S1: 1 inch = 25. 4mm <br />a. Nails spaced at 6 inches at intermediate supports where spans are 48 inches or more. For nailing of wood structural panel and <br />particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing ore permitted to be common, box or casing. <br />b. Spacing shall be 6 inches on center on the edges and 12 inches on center at intermediate supports for nonstructural applications. <br />Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). <br />c. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the ceiling joist is <br />fastened to the top plate in accordance with this schedule, the number of toenails in the rafter shall be permitted to be reduced by <br />one nail. <br />(3 <br />Q <br />O <br />L <br />t� <br />C <br />i� <br />V) <br />N <br />0 <br />(D <br />C <br />O <br />i) <br />L <br />N <br />C <br />O <br />C) <br />O <br />N <br />O <br />N <br />(D <br />11 <br />CL <br />O <br />U <br />