FLOOR PLAN - LEGEND <br />101 DOOR TAG <br />1 i PARTITION TAG <br />1 i STOREFRONT TAG <br />Room name <br />101 A ROOM TAG <br />o PROPOSED NEW WALL <br />EXIST. WOOD STUD WALL <br />PARTIAL HEIGHT WALL <br />EXIST. CMU WALL <br />o FIRE EXTINGUISHER <br />EFF UNDER CABINET LIGHT <br />RCHITECTURAL NOTE <br />1. ALL FULL -HEIGHT PARTITIONS SHALL EXTEND TIGHTLY TO STRUCTURE ABOVE WITH <br />DEFLECTION -TYPE TOP TRACK. ALL OTHER WALLS SHALL BE CONSTRUCTED TO 6" ABOVE <br />SCHEDULED CEILING. ANY ADDITIONAL BRACING SHALL BE PROVIDED BY THE FRAMING <br />CONTRACTOR. <br />2. STUDS SHALL BE INSTALLED SEATED SQUARELY (WITHIN 1/16") AGAINST THE WEB PORTION OF <br />THE TOP AND BOTTOM TRACKS. TRACKS SHALL REST ON A CONTINUOUS, UNIFORM BEARING <br />SURFACE. <br />3. TEMPORARY BRACING MAY BE PROVIDED AND LEFT IN PLACE UNTIL THE WORK IS <br />PERMANENTLY STABILIZED. <br />4. VERTICAL ALIGNMENT (PLUMBNESS) OF STUDS SHALL BE WITHIN 1/960TH (1/8" IN 10'-0") OF THE <br />SPAN. HORIZONTAL ALIGNMENT OF WALLS SHALL BE WITHIN 1/960TH (1/8" IN 10,-0") ON THEIR <br />RESPECTIVE DISTANCES. <br />5. SPACING OF STUDS SHALL NOT BE MORE THAN ± 1/8" FROM THE DESIGNED SPACE PROVIDED <br />THAT THE CUMULATIVE ERROR DOES NOT EXCEED THE REQUIREMENTS OF THE FINISH <br />MATERIALS. <br />6. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. REFER TO DIMENSIONING <br />NOTES ON SHEET G001. <br />7. ALL NEW DOORS SHALL BE 4" OFF WALL (HINGE SIDE) U.N.O. <br />8. PROVIDE (2) ROWS MINIMUM 8" HIGH, 3/4" FIRE RETARDANT PLYWOOD, OR 20-GAUGE <br />HORIZONTAL STRAPPING ON STUDS AT ALL WALLS WITH CABINETS. <br />9. ANY DRYWALL FINISH WHICH IS EXISTING TO REMAIN SHALL BE PATCHED, PRIMED AND PAINTED <br />TO'LIKE NEW' CONDITION AND TO ACCEPT NEW FINISHES. <br />CONTRACTOR SHALL DETERMINE BEST METHODS FOR PATCHING, OR IF DRYWALL WILL NEED <br />TO BE REMOVED AND REPLACED TO ACHIEVE DESIRED FINISH. <br />10. THERMOSTATS, FIRE EXTINGUISHERS, CABINETS, OR ANY OTHER WALL MOUNTED <br />ARCHITECTURAL ACCESSORY SHALL NOT BE INSTALLED ON ANY WALL WITH GRAPHIC <br />STRETCHINGS OR SPECIALITY FINISHING. <br />11. HYDRONIC PIPING IN EXTERIOR WALL CAVITIES ARE TO RECEIVE PIPE INSULATION. <br />12. FRAMING, GYPSUM BOARD AND EXTERIOR INSULATION TO EXTEND TO UNDERSIDE OF DECK AT <br />EXTERIOR ENVELOPE. <br />BLOCKING NOTE: <br />GC TO PROVIDE ALL 3/4" THK. FIRE -RETARDANT IN -WALL & IN -MILLWORK PLYWOOD <br />BLOCKING AS REQUIRED FOR TELEVISIONS, PLUMBING ACCESSORIES, COAT HOOKS, MILLWORK AND <br />SIGNAGE. <br />KEYNOTES <br />151 4' x 8' x 3/4" FIRERATED PLYWOOD MOUNTED AT FLOOR TO 8'-0" AROUND PERIMETER OF <br />ROOM WHERE INDICATED <br />C11 t V�'tg3.iy�7 k..N i°��-` �# , I <br />i"ia% rvr <br />1 ,a 0 E)i"Ive <br />gar ipa, Floridap 6 <br />4 <br />All reproduction & intellectual property <br />rights reserved 2017 <br />Project <br />Jill <br />41 <br />n. <br />DMG (FL) - <br />ZEPHYRHILLS <br />5935 7th Street Zephyrhills, <br />FL 33542 <br />Prepared for <br />DAVITA MEDICAL GROUP <br />In Association with: <br />HEt_S & ASSOCIATES, INC. <br />CONTACT: KARL HEES <br />1381 5TH ST <br />SARASOTA, FI- 34236 <br />PHONE: 941.955.4555 <br />GENESIS ENGINEER GROUP, LLC <br />CONTACT: MIKE HANEY <br />1000 N. ASHLEY DR. #900 <br />TAMPA, FL <br />PHONE: 813.523.6455 <br />GENESIS ENGINEER GROUP, LLC <br />CONTACT: MIKE HANEY <br />1000 N. ASHLEY DR. #900 <br />TAMPA, FL <br />PHONE: 813.523.6455 <br />Professional <br />k v <br />.. o <br />e <br />F i= <br />yy` q L u,�4 )tygg kd <br />t` <br />rew 1R #l?20 9 <br />15$05 y C�:53 AM <br />No. Revision Description Date <br />1 PERMIT AND BID SET 12/10/2018 <br />No. Revision Description Date <br />2 OWNER REVISIONS 5/151 <br />Drawn By: WJ Checked By: SRS <br />Project Number: 18190 <br />Sheet Title <br />FIRST FLOOR <br />DIMENSION <br />PLAN <br />Original drawing is 24 x 36 Do not <br />scale contents of drawing <br />Sheet Number <br />1 FIRST FLOOR DIMENSION PLAN <br />1/4" = 1'-0" <br />A1010D <br />