C
<br />A
<br />FL #
<br />F116299-R4
<br />Application Type
<br />Revision
<br />Code Version
<br />2017
<br />Application Static
<br />Pending FBC Approval
<br />Com men is
<br />Archived
<br />r
<br />Product Manufacturer
<br />KAYCAN LTD
<br />Address/Phone/Email
<br />1 Memorial Drive
<br />Richford, VT 05476
<br />1 662) 252-9991 Ext 231
<br />Ice.lundi ne@kpproducts, com
<br />AuUhonzed Signature
<br />Joe Lundine
<br />)oe.l un di ne@kpprodu hs, com
<br />Ted -cal Representative
<br />Joe Lundine
<br />Address/Phone/Email
<br />402 Boyer St
<br />'i
<br />Williston, VT 05495
<br />662 2S2-9991
<br />( )
<br />)oe.lundine@kppmducts.com
<br />Quality Assurance Representative
<br />Joe Lundine
<br />Address/Phone/Email
<br />402 Boyer St
<br />Williston, VT 05495
<br />(662) 252-9991
<br />joe.lundine@kpproducts.com
<br />Category
<br />Panel Walls
<br />Subcategory
<br />Siding
<br />Compliance Method
<br />P
<br />Evaluation Report from a FloridaRegistered Architect or a Licensed
<br />p 9
<br />Florida Professional Engineer
<br />Evaluation Report -Hardcopy Received
<br />Florida Engineer or Architect Name who
<br />Robert J. Amoruso, P.E.
<br />developed the Evaluation Report
<br />Rorida License
<br />PE-49752
<br />Quality Assurance Entity
<br />Architectural Testing, Inc.
<br />Quality Assurance Contract Expiration Date
<br />12/31/2020
<br />Validated By
<br />Steven M. LYich, PE
<br />IV -
<br />Validation Checklist -Hardcopy Received
<br />Certificate of Independence
<br />R16.243_F4_4¢1 CI 24�5 Reel and 2209 Re��2.ss.pcif
<br />Referenced Standard and Year (of Standard) Standard
<br />Year
<br />ASTM D1929
<br />2012
<br />ASTM D2843
<br />2010
<br />ASTM D3679
<br />2011
<br />ASTM D635
<br />2010
<br />ASTM D7254
<br />2007
<br />ASTM E84
<br />2014
<br />ASTM G155-05a
<br />2005
<br />Equivalence of Product Standards
<br />Certified By
<br />Florida Licensed Professional Engineer or Architect
<br />N 1629?. R4 Eauiv EER 209 Rev2 D6-Vinyl-Siding
<br />ss pdf
<br />FL16299 R4 Eauiv2435 Ravi PerfectimShinalcSidina
<br />ss.pdf
<br />Secdms from the G-de
<br />Rodur_t Approval Method
<br />Method i Option D
<br />Date Submitted
<br />12/08/2017
<br />Date Validated
<br />12/12/2017
<br />Date Pending FBC Approval
<br />12/20/2017
<br />KAYCAN LTD
<br />0
<br />D6 "CHMOND D6A,SHBURY VINYL (PVC) ,SIDING
<br />i =
<br />INSTALIlATIONANCHORWE
<br />DETAILS
<br />2'
<br />1 28
<br />INSTALLATION NOTES
<br />d E w
<br />GENERAL NOTES:
<br />1. THIS PRODUCT HAS BEEN TESTED AND DESIGNED TO COMPLY WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE
<br />1. ANCHORS $HALL BE THE TYPE, SIZE, EMBEDMENT AND EDGE DISTANCE SHOWN HEREIN FOR
<br />m ¢
<br />IFBC)- BUILDING AND RESIDENTIAL VOLUMES EXCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)A7 THE DESIGN
<br />RESPECTIVE SUBSTRATE.
<br />PRESSURE(S) SHOWN ON THIS SHEET (SEE TABLE).
<br />2. INSTALLATION ANCHORS SHALL BE INSTALLED AS SHOWN ON THE "WOOD FRAME
<br />RATING DESIGN PRESSURE IN PSF BASED UPON SIGNED AND SEALED INTERTEK TESTING
<br />2. STRUCTURAL PERFORMANCERAIN ( 1
<br />INSTALLATI ON' SECTIONS ON SHEETS 4 AND 5.
<br />SERVICES TEST REPORT NO. 101062528TOR-002, DATED 2/2DA3 INCLUDING ASSOCIATED LABORATORY STAMPED DRAWINGS.
<br />3, MINIMUM EMBEDMENTAND EDGE DISTANCE EXCLUDE WALL FINISHES (INCLUDING BUT NOT
<br />- > O
<br />21- A SAFETY FACTOR OF 1.5 WAS APPLIED TO THE MAXIMUM TESTED LOADING PER ASTM D 52061N ACCORDANCE WITH THE
<br />LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING).
<br />w r
<br />CURRENT EDITION OF THE FLORIDA BUILDING CODE(FBC)- BUILDING AND RESIDENTIAL VOLUMES .
<br />4. INSTALLATION ANCHOR DETAILS:
<br />U
<br />U 8
<br />22. BASED ON ASTM 03679, ANNEX A WHICH ALLOWS UTILIZATION OF A PRESSURE EQUALIZATION FACTOR OF 0.36 RESULTS IN
<br />q 1 USE 0.74" DIAMETER x 1-1 JZ" LUNG RING SHANK ROOFING NAIL WITH 0.040"DIAMETER HEAD
<br />a,
<br />A DESIGN PRESSURE RATING OF -138.9 PSF WHEN INSTALLED AGAINST A MINIMUM 7/18" THICK SHEATHING, A NEGATIVE
<br />SURFACE.
<br />FOR SIDING AND TRIM INSTALLATION.
<br />w A p
<br />DESIGN PRESSURE SIGNIFIES PRESSURE LOADING ACTING AWAY FROM THE SIDING
<br />2.3, DESIGN PRESSURE SHOWN IN DESIGN PRESSURE RATING TABLE ON SHEET f BASED ON INSTALLATION OVER SOLID
<br />4.2. SEE SHEETS 4 AND 5 FOR ADDITIONAL DETAILS,
<br />h- ❑ K z
<br />J S
<br />SHEATHING. SEE CHAPTER 7, VINYL SIDING INSTALLATION OVER FOAM PLASTIC SHEATHING FOR ADJUSTED DESIGN
<br />S. ALL FASTENERS SHALL HAVE CORROSION RESISTANT COATINGS OR BE MADE OF CORROSION
<br />-'
<br />2 a O 5 p
<br />PRESSURE REQUIREMENTS.
<br />RESISTANT MATERIALS COMPATIBLE WITH THE SUBSTRATE MATERIALS.
<br />fl =
<br />3. ADEQUACY OF THE EXISTING STRUCTURAL WOOD FRAMING COMPRISING THE ATTACHMENT SUBSTRATE FOR THE SIDING SHALL
<br />6. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE
<br />N F
<br />w z in 7:e'
<br />Z
<br />BE DETERMINED TO BE CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THAT STRUCTURE AND
<br />MATERIALS WFfH THE FOLLOWING PROPERTIES:
<br />,� U ,t H
<br />0 fi
<br />IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD FOR THE PROJECT.
<br />g
<br />t
<br />BE FOR STRUCTURAL INADEQUACY, CRACKS OR DEFECTS THAT SHALL
<br />6.1. 2. WALL STUDS - MIN. SPECIFIC GRAVITY OF 0.42 (EQUATES TO SPRUCE -PINE -FUR).
<br />OZ QS
<br />4. SUBSTRATES RECEIVING VINYL SIDING SHALL CHECKED
<br />BE ELIMINATED.
<br />62. 711 V THICK PLYWOOD -SPECIES GROUP 1 OR 2 (APA VOLUNTARY PRODUCT STANDARD PS
<br />5. INSTALLATION OF SIDING ACCESSORIES AND ACCESSORIES SUCH AS CORNER POSTS, STARTER STRIPS, AND TRIM AROUND
<br />OPENINGS SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC) - BUILDING
<br />1) MINIMUM.
<br />m Uw' c83
<br />3
<br />AND RESIDENTIAL VOLUMES AS APPLICABLE AND THE MANUFACTURER'S INSTRUCTIONS.
<br />6.3. 7/16" OSB -SHEATHING GRADE (APA VOLUNTARY PRODUCT STANDARD PS 2) MINIMUM.
<br />y g&¢$
<br />6. SITE CONDITIONS THAT DEVIATE FROM THE DETAILS OF THIS DRAWING REQUIRE FURTHER ENGINEERING EVALUATION BY A
<br />LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT.
<br />- F&
<br />7. WALLS WHERE VINYL SIDING SHALL BE INSTALLED MUST BE DESIGNED BY A LICENSED PROFESSIONAL ENGINEER, ARCHITECT
<br />OR OTHER DESIGN PROFESSIONAL AS ALLOWED BYAND IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA
<br />VINYL SIDING SPECIFICATIONS:
<br />BUILDING CODE (FBC)- BUILDING AND RESIDENTIAL VOLUMES.
<br />7.1. MINIMUM SHEATHING REQUIREMENTS ARE SHOWN IN INSTALLATION NOTE 6.2 AND 63.
<br />1. KAYCAN BUILDING PRODUCTS VINYL SIDING IS MANUFACTURED FROM A FORMULATED PVC
<br />8- WALLS WHERE VINYL SIDING SHALL BE INSTALLED SI-IALL BE PROVIDED WITH A WATER RESISTIVE BARRIER IN ACCORDANCE
<br />POWDER COMPOUND MEETING THE SPECIFICATIONS OF ASTM D3579.
<br />WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC)-BUILDING AND RESIDENTIAL VOLUMES.
<br />2, WALL THICKNESS'.
<br />8.1. A WATER -RESISTIVE AARRIER IS REQUIRED PER THE CURRENT EDITION OF THE FLORIDA BUILDING CODE AND SHALL BE A
<br />2,1 D6: 0.060" MIN.
<br />MINIMUM OF ONE LAYER OF N0.15 ASPHALT FELT, COMPLYING WITH ASTM D 226 FOR TYPE 1 FELT OR OTHER APPROVED
<br />MATERIALS.
<br />3. PANEL LENGTHS:
<br />3.1. D6:12' - D" LONG
<br />Robes J. A- P.E.
<br />Flo,be P.E. NoAb52
<br />TABLE OF CONTENT
<br />SHEET
<br />DESCRIPTION
<br />1
<br />GENERAL AND INSTALLATION NOTES
<br />2
<br />COMPONENTS AND BILL OF MATERIALS
<br />3
<br />COMPONENTS
<br />4
<br />VERTICAL INSTALLATION CROSS SECTION
<br />5
<br />TYPICAL INSTALLATION DETAIL
<br />DESIGN PRESSURE (PSF) RATING
<br />DESIGN PRESSURE (PSF) RATING
<br />SIDING SERIES (SEE NOTES 2.1, 2.2 & 2.3)
<br />06 RICHMOND - 138.9
<br />D6 ASHBURY - 138.9
<br />m
<br />n,
<br />0
<br />r`
<br />m �RILL �
<br />H zw w z
<br />W0,0 as
<br />OEz �zo 0
<br />Ili. QF QE o
<br />0.020� 0.156
<br />0.125 0 Zqj
<br />0.793 w ¢
<br />0 0 0.15 4.250
<br />0.375 z $ $
<br />a
<br />0.188 1.043 0.750 "
<br />1.375 a p
<br />1,700 DETAIL A I 0.042
<br />�i1 �
<br />>a>uzi Q w
<br />2.550 1.543 6 o a� o m p z m
<br />1.700 z¢'Sm� 2
<br />4 KAYCAN VINYL 2�z
<br />0. 60 }o<D kap
<br />1, n
<br />0.750
<br />3/4° J-CHANNEL Y0
<br />45' fr41
<br />0.850 55
<br />DRAWING NO. VJJ34 {
<br />0.125 RO.040
<br />0-375 P
<br />3 KAYCAN ALUMINUM STARTER STRIP/TRIM
<br />PRODUCT NO, 1082 DRAWING NOI ACAAS-18000A Robed J-Amoroso, P.E.
<br />Fonda P.E. No. 49752
<br />a'
<br />r
<br />o
<br />n
<br />F U x
<br />K
<br />16" MAX. O.C.
<br />$7U0 SPACING
<br />~ i x
<br />U U r-
<br />STUD SPACING
<br />> 16" O.C.
<br />do �.
<br />z �2p
<br />f
<br />F7
<br />�5 ao
<br />�w �w
<br />7/16" MIN. THICKNESS
<br />7/16" NIN. THICKNESS
<br />m 4
<br />SHEATHING (PLYWOOD/OS B)
<br />SHEATHING (PLYWOOD/OS8)
<br />Z w
<br />Q
<br />Q J o
<br />INSTALLAION O
<br />INSTALLATION O
<br />6
<br />J ~
<br />z 0
<br />ANCHOR
<br />ANCHOR
<br />w `ti
<br />1-0ort
<br />< M
<br />'t
<br />i OpG� ffe 0yy
<br />VINYL SIDING i 2
<br />VINYL SIDING 02
<br />QQ
<br />a¢ eP
<br />U $ d
<br />Y
<br />ak„55
<br />11.13" VERTICAL
<br />11.13" VERTICAL
<br />ANCHOR SPACING
<br />ANCHOR SPACING
<br />16" HORIZONTAL
<br />8" HORIZONTAL
<br />ANCHOR SPACING
<br />ANCHOR SPACING
<br />INSTALLATION ANCHORING FOR
<br />INSTALLATION ANCHORING FOR
<br />16" MAXIMUM STUD SPACING
<br />STUD SPACING EXCEEDING 16"
<br />(INSTALLATION ANCHOR
<br />MAXIMUM (24" 0 C SHOWN)
<br />Flodi R E. No. 49752
<br />EMMBEDMENT INTO 2X STUBS)
<br />(INSTALLATION ANCHOREMBEDMENT
<br />INTO SHEATHING)
<br />-2.98 L-R14.05
<br />11.13
<br />ll,l3
<br />5,56 5,56
<br />4.050
<br />SURFACE EXPOSE 11 1/8"
<br />(DQDG RICHMOND PANEL/D6 ASHBURY
<br />DRAWING NO VSAAL-0800 PRODUCT NO. 0081
<br />BILL OF MATERIALS
<br />ITEM
<br />DESCRIPTION
<br />MATERIAL
<br />1
<br />KAYCAN D6 RICHMOND SIDING
<br />VINYL (PVC)
<br />2
<br />KAYCAN D6 ASHBURY SIDING
<br />VINYL (PVC)
<br />3
<br />KAYCAN STARTER STRIP
<br />VINYL (PVC)
<br />4
<br />KAYCAN J-CHANNEL
<br />VINYL (PVC)
<br />5
<br />NSTALLATION ANCHOR: 0.14" DIA. x 1-1/2" LONG RING SHANK
<br />ROOFING NAIL WITH 0.40" DIA. HEAD MIN,
<br />GALV. STEEL OR
<br />STAINLESS STEEL
<br />EXTERIOR
<br />2 x 4 STUDS MINIMUM,
<br />SEE GENERAL NOTES 3, 6 AND 7 ON SHEET 1.
<br />INTERIOR
<br />7/16" PLYWOOD/OSB SHEATHING MINIMUM.
<br />SEE GENERAL NOTE 7 ON SHEET 1.
<br />WATER RESISTIVE BARRIER,
<br />SEE GENERAL NOTE 8 ON SHEET 1.
<br />INSTALLATION ANCHOR SPACING.
<br />11.13" VERTICAL SPACING (SHOWN).
<br />FOR HORIZONTAL SPACING,
<br />SEE TABLE AT RIGHT.
<br />HORIZONTAL ANCHOR SPACING (IN)
<br />16" O.C. 2X STUD
<br />SIDING
<br />COMPONENT
<br />SUBSTRATE
<br />SPACING (IN)
<br />06 VINYL SIDING
<br />MIN. 7/16" PLYWOOD/O56
<br />AND 2X STUD
<br />16
<br />STARTER STRIP
<br />MIN, 7/16" PLYWOOD/OSB (2X STUDS > 16" O.C.
<br />06 VINYL. SIDING
<br />IN, 7/16" PLYWOOD/O58
<br />ONLY
<br />6
<br />STARTER STRIP
<br />VERTICAL ANCHOR SPACING (IN)
<br />16" O.C. 2X STUD
<br />SIDING
<br />COMPONENT
<br />SUBSTRATE
<br />SPACING (IN)
<br />C6 MNYL SIDING
<br />MIN, 7/16" PLYWOOD/OSB
<br />AND 2X STUD
<br />11.13
<br />J-CHANNEL
<br />15
<br />MIN. 7/16" PLYWOOD/OSB (2X STUDS > 16" O.C.
<br />VINri SIDINGMIN.
<br />r�l-
<br />7/i6" PLYWOOD/OSB
<br />ONLY
<br />CHANNEL
<br />6
<br />INTERIOR
<br />1 2 D6 VINYL SIDING D6 VINYL SIDING i INSTALLATION ANCHOR O
<br />1 2 I
<br />INSTALLATION ANCHOR O
<br />16" VERTICAL ON CENTER
<br />SPACING - 2X STUD EMB.
<br />EXTERIOR
<br />if 8" VERTICAL ON CENTER
<br />ALUMINUM STARTER STRIP IQ SPACING - MIN. 7/16" SHEATHING
<br />OVINYL J-CHANNEL USED 'p 4" MAX.
<br />AS VERTICAL TRIM
<br />3O ALUMINUM STARTER STRIP D6 INSTALLATION
<br />D6 INSTALLATION J-CHANNEL VERTICAL TRIM
<br />ALUMINUM STARTER STRIP SEE ALUMINUM STARTER STRIP INSTALLATION
<br />FOR ADDTIONAL DETAILS
<br />Robert J.Amo 5D, P.E.
<br />Florde P.C. No. 49752
<br />- J. Mnoveo. P.E.
<br />Florida P.E. N, d9.
<br />a '¢
<br />5 0
<br />� ZZ
<br />W� �µ
<br />0 SIDING PANEL OVERLAP w o 0 0 t
<br />Of
<br />d H
<br />aw �
<br />8" MAX. O.C. SPACING z 8 wo
<br />O 16" MAX. STUD SPACING TYPICAL >q
<br />w
<br />> v,>z Q N
<br />�O� O R
<br />z<sm5 WZw
<br />0 0
<br />U�rL
<br />}0<Ng
<br />� U � i5
<br />�r
<br />x
<br />� �y�Ripp
<br />OPTION 2 ANCHORING
<br />TYPICAL INSTALLATION DETAIL
<br />(IS NOT EXACT PROFILE REPRESENTATION OF D6 SIDING)
<br />Pori J.Amoroso,P.E.
<br />LTnrida P.E. N0. 49752
<br />n
<br />I I .II I., , _161 Ya- , 3 •. , .. .. I 01AIII4.1 a a. -A I", I I ,,,. I -r-- i I -
<br />f ;a'
<br />
|