My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5967 14th St
Zephyrhills
>
Building Department
>
Building Plans
>
5967 14th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 1:02:08 AM
Creation date
2/19/2025 8:51:38 AM
Metadata
Fields
Template:
Building Plans
Street #
5967
Location
14th St
Contractor
Butterfield Investments
Building Plans - Permit #
909
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />6TH EDITION, 2017 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01/08 AND HAVING A <br />FOSSIL- FUEL- BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2017 6TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII - ELECTRICAL) <br />NEC 2017: 210.12 - ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 - INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />N CITES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLETS HEIGHTS AS <br />MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO <br />BE: 12" AFF (GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE POSSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42" CENTERLINE AFF. <br />4. ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE <br />FOR THE INSTALLATION & SIZING OF <br />ALL ELECTRICAL, WIRING & ACCESSORIES. <br />5. GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER N.E.C. 2017 <br />SYMBOL I DESCRIPTION <br />$ SWITCH <br />$3 3 WAY SWITCH <br />$4 4 WAY SWITCH <br />$R RHEOSTAT SWITCH <br />i� 110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />6GFI 110 V RECEPTICLE - GROUND FAULT <br />6AFI 110 V RECEPTICLE - ARC FAULT <br />8 110 V RECEPTICLE - WATERPROOF OUTLET <br />6 220 V RECEPTICLE <br />In DUPLEX OUTLET IN FLOOR <br />36 110 V QUAD <br />36wp 110 V QUAD WATERPROOF OUTLET <br />RECESSED INCANDESCENT <br />�} LIGHT FIXTURE - WALL OR CEILING (TYP) <br />�- EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />FLOURESCENT FIXTURE <br />FLOOD LAMPS <br />�--°�- VANTITY LIGHT <br />GD PUSH BUTTON FOR GARAGE OPENER <br />S&D SMOKE /FIRE DETECTOR/ALARM <br />D& SMOKE/CARBON MONOXIDE DETECTOR - COMBO <br />© CARBON MONOXIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN W/L <br />=' I DISCONNECT <br />200 AMP - <br />METER SOCKET <br />UNDERGROUND SERVICE <br />(IF ' AVAILABLE) <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />3- 2/0 THNN CU FEEDERS <br />2" GALV RISER <br />2" CHASE W <br />OR (3) #410/T W#AL. THW COP. <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL ON INSIDE GARAGE WALL <br />2" GALV NIPPLE <br />#4 CU DRIVEN GROUND <br />RODS 2 EACH 8'-0" APART MIN. <br />`-3/8" X 8' GROUND ROD <br />CONCRETE ENCASED "LIFER" ELECTTODE REQUIRED PER ART 250-50 <br />N.E.C. MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT. <br />BUTTERFIELD INVESTMENTS INC RICK GOLLHARDT - DRAFTSMAN <br />5967 14TH STREET 813-781-3651 <br />Z EP HYR H I LLS, FLORIDA rgollhardt@tampabay.rr.com <br />D.W.SMITH,M.S.,P.E.#53008 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE:813-469-2289 E-MAIL: dwsflpe@earthlink,net <br />ELECTRICAL <br />SCALE <br />DO NOT SCALE <br />DATE <br />26 SEPT 2020 <br />SHEET OF <br />9 OF 10 <br />TERI BUTTERFIELD <br />CDC1332445 <br />DESIGN/DRAWN <br />R. GOLLHARDT <br />CHECKED <br />D.W.S. <br />2020-0831 <br />
The URL can be used to link to this page
Your browser does not support the video tag.