MATERIALS <br />1. <br />f'c 8" precast lintel = <br />3500 psi <br />2. <br />f'c prestressed lintel = <br />6000 psi <br />3. <br />Grout per ASTM C476 <br />f'g = 3000 <br />psi w/ maximum 3/8 <br />inch <br />aggregate & 8 to 11 <br />inch slump <br />4. <br />Concrete Masonry Units (CMU) per <br />ASTM C90 w/minimum <br />net area <br />compressive strength <br />= 1900 psi <br />5. <br />Rebar per ASTM A615 <br />grade 60 <br />6. <br />Prestressing strand per <br />ASTM A416 <br />grade 270 low relaxation <br />7. <br />Mortar per ASTM C270 <br />type M or S <br />L 11 N <br />DETAIL "B"-' <br />SAFE LOAD TABLE NOTES <br />1. All values based on minimum 4 inch <br />nominal bearing. <br />Exception: Safe loads for unfilled lintels must <br />be reduced by 20% if bearing length is <br />less than 6 1 /2 inches. <br />2. N.R. = Not Rated <br />3. Safe loads are superimposed allowable loads. <br />4. Safe loads based on grade 40 or grade 60 <br />field rebar. <br />5. One #7 rebar may be substituted for two <br />#5 rebars in 8" lintels only <br />6. The designer may evaluate concentrated <br />loads from the safe load tables by <br />calculating the maximum resisting moment <br />and shear at d-away from face of support. <br />7. For composite lintel heights not shown, <br />use safe load from next lower height shown. <br />8. For lintels lengths not shown, use safe load <br />from next longest length shown <br />9. All safe loads in units of pounds per linear <br />foot <br />10. All safe loads based on simply supported <br />span. <br />11. The number in the the parenthesis <br />indicates the percent reduction for grade 40 <br />field added rebar. <br />Example 7'-6" lintel type 8F32-1 B safe <br />gravity load = 6472_ <br />GENERAL NOTES <br />1. <br />Provide full mortar bed and head joints. <br />2. <br />Shore filled lintels as required. <br />3. <br />Installation of lintel must comply <br />with the architectural <br />and/or structural documents. <br />4. <br />U-Lintels are manufactured with <br />5 1 /2" long notches at <br />the ends to accomodate vertical <br />cell reinforcing and grouting. <br />5. <br />Reference the CAST-CRETE Load <br />Deflection Graph brochure <br />for lintel deflection information. <br />6. <br />Bottom field added rebar to be <br />located at the bottom <br />of the lintel cavity. <br />7. <br />7/32" diameter wire stirrups are <br />welded to the <br />bottom steel for mechanical anchorage. <br />8. <br />Cast -in -place concrete may be <br />provided in composite lintel <br />in lieu of concrete masonry units. <br />9. Safe load rating based on rational design analysis per <br />ACI 318 and ACI 530 <br />10. Product Approvals: Miami -Dade County, Florida Nos. <br />03-0606.05 & 03-0605.04. Florida Certificate of Product <br />Approval number FL158. <br />11. The exterior surface of lintels installed in exterior concrete <br />masonry walls shall have a coating of stucco applied in <br />accordance with ASTM C-296 or other approved coating. <br />12. Lintels loaded simultaneously with vertical (gravity or <br />uplift) and horizontal (lateral) loads should be checked <br />for the combined loading with the following equation: <br />Applied vertical load + Applied horizontal load < 1 .0 <br />Safe vertical load Safe horizontal load <br />13. Additional lateral load capacity can be <br />obtained by the designer by providing additional reinforced <br />concrete masonry above the lintel. See detail at right: <br />LINTEL, PLAN <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />8" <br />SAFE GRAVITY LOADS FOR <br />PRECAST & PRESTRESSED U-LINTELS <br />SAFE LOAD <br />POUNDS PER LINEAR FOOT <br />MARK <br />No. <br />LENGTH <br />TYPE <br />8U8 <br />8F8-0B <br />8F8-1 B <br />L <br />1 <br />2'-10" <br />(34") <br />PRECAST <br />2231 <br />3069 <br />3069 <br />L <br />2 <br />2'-8" to <br />3'-6" <br />(42") <br />PRECAST <br />2231 <br />3069 <br />3069 <br />L <br />3 <br />3 -7 to <br />4'-0" <br />(48") <br />PRECAST <br />1966 <br />2561 <br />2693 <br />L <br />4 <br />4'-16' <br />(54") <br />PRECAST <br />1599 <br />2189 <br />189 <br />L <br />5 <br />4 -7 to <br />5'-4" <br />(64") <br />PRECAST <br />1217 <br />1349 <br />1663 <br />L <br />6 <br />5 -5 to <br />5'-10" <br />(70") <br />PRECAST <br />1062 <br />1105 <br />1451 <br />L <br />7 <br />5'- 1t to <br />6'-6" <br />(78") <br />PRECAST <br />908 <br />1238 <br />1238 <br />L <br />8 <br />6-7 to <br />7'-6" <br />(90") <br />PRECAST <br />743 <br />1011 <br />1011 <br />L <br />9 <br />7:-7 ,to <br />9-4 <br />(112) <br />PRECAST <br />554 <br />699 <br />752 <br />L <br />10 <br />9'-5" to <br />10'-6" <br />(126") <br />PRECAST <br />475 <br />535 <br />643 <br />L <br />11 <br />10 -7 to <br />11'-4" <br />(136") <br />PRECAST <br />362 <br />582 <br />582 <br />L <br />12 <br />11 -5 to <br />12'-0" <br />(144") <br />PRECAST <br />337 <br />540 <br />540 <br />L <br />13 <br />12 -1 to <br />13'-4" <br />(160") <br />PRECAST <br />296 <br />471 <br />471 <br />L <br />14 <br />13'-5" to <br />14'-0" <br />(168") <br />PRECAST <br />279 <br />424 <br />442 <br />L <br />15 <br />14 -1 to <br />14'-8" <br />(176") <br />PRESTRESSED <br />N.R. <br />NR <br />458 <br />L <br />16 <br />14 -9 to <br />15'-4" <br />(184") <br />PRESTRESSED <br />N.R. <br />NR <br />412 <br />L <br />17 <br />15 -5 to <br />17'-4" <br />(208") <br />PRESTRESSED <br />N.R. <br />NR <br />300 <br />DETAIL "B" <br />SAFE GRAVITY LOADS FOR 8" PRECAST <br />w/ 2" RECESS DOOR U-LINTELS <br />POUND �1 PER LINEAR FOOT <br />MARK <br />No. <br />LENGTH <br />TYPE <br />8RU6 <br />8RF6-OB <br />8RF6-1 B <br />D <br />1 <br />3 -8 to <br />4'-4" <br />(52") <br />PRECAST <br />1635 <br />1749 <br />1891 <br />D <br />2 <br />4'-5" to <br />4'-6" <br />(54") <br />PRECAST <br />1494 <br />1596 <br />1756 <br />D <br />3 <br />4'-7" to <br />5'-8" <br />(68") <br />PRECAST <br />866 <br />920 <br />1167 <br />D <br />4 <br />5'-9" to <br />5'-10" <br />(70") <br />PRECAST <br />810 <br />859 <br />1113 <br />D <br />5 <br />5-11to <br />6'-8" <br />(80") <br />PRECAST <br />797 <br />901 <br />901 <br />D <br />6 <br />6'-9" to <br />7'-6" <br />(90") <br />PRECAST <br />669 <br />755 <br />755 <br />D <br />7 <br />7'- 7to <br />9'-8" <br />(116") <br />PRECAST <br />411 <br />466 <br />526 <br />BUTTERFIELD INVESTMENTS INC <br />5985 14TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE-DADE CITY,FL❑RIDA 33525 <br />PHONE:813-469-2289 E-MAIL: dwsflpe@earthlink, net <br />2" RECESS <br />DETAIL "DB" <br />RICK GOLLHARDT - DRAFTSMAN <br />813- 781- 3651 <br />rgollhardt@tampabay.rr.com <br />LINTEL PLAN <br />SCALE <br />DO NOT SCALE <br />DESIGN/DRAWN <br />R. GOLLHARDT <br />DATE <br />30 AUG 2020 <br />CHECKED <br />D.W.S.,p.e. <br />SHEET OF <br />4 OF 9 <br />JOB NO. <br />ENGINEER LICENCE #53608 <br />2020-0818 <br />