Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4%1" CROWN <br />STAPLES @ 6" O.C. VERT BETWEEI <br />STUDS (NOTED THUS:—) - OFFSE- <br />STAPLES BETWEEN STUDS AS SHOWI <br />WALL SHEATHING <br />DOUBLE JOIST CONS <br />(Not required if both loa <br />Filler <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />16GAxl-1/2" LONG (3/4"-1" 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />CROWN) STAPLES @ 6" OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) DOUBLE JOIST CONNECTION <br />N.T.S. <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF �—� <br />HOME H C G <br />GARAGE SIDE O O O <br />5-0" a - <br />I = <br />r7 <br />STUB -OUT FOR 1'-0" L 0 9 <br />GAS METER 0 o <br />�• U <br />O F <br />N 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />"IT-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />L <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />net <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1 /8" or two 1/2 <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking <br />BEARING Use 3" (10d) nails at <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls <br />Load bearing wall must stack ���� <br />nvpr cnn�ehein hlnr4e �nrp � <br />N <br />w <br />X <br />CONT. #5 <br />BAR <br />FILL CELL <br />STD. 90° <br />HOOK <br />STD. 90° HOOK r— BOND BEAM <br />_�-- CONT. #5 <br />A� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />1 BOND BEAM <br />v <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />BEARING COLUMN I ` 7 � <br />�CONT. BASE PLATE <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />—PLYWOOD FLOOR <br />` SHEATHING PER PLAN <br />CONNECTION <br />f—TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />i' <br />'--MASONRY WALL OR <br />Pi <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />I <br />ii# <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" <br />max. <br />4" max. Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />-- <br />Series Depth End Intermediate <br />- 9-1/2" 1 2-8d <br />2-8d <br />BCI5000s 11-7/8" 2-8d <br />3-8d - <br />0 <br />14" 2-8d <br />5-8d <br />Clinch nails <br />C <br />9-1/2" 2-8d <br />2-8d <br />when <br />BCI 6000s® 11-7/8�_2-8d - <br />3-8d <br />possible <br />BCI 6500s® _ 14" 2-8d _ <br />5-8d- <br />-- t 16" _ 2-8d <br />6-8d <br />11-7/8" 2-8d <br />3-8d <br />BCI 60se j 14 2-8d <br />5-8d <br />Ti fit <br />9 ht <br />16" Mid <br />5-8d <br />11 7./8" 3-16d <br />3-16d4" <br />2x4/PI ood/OSB web stiffener <br />2" min. BCI 90s® 14 5-16d <br />5-16d <br />required when indicated or <br />max. <br />L- 16" 6-16d <br />6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. <br />N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below - Load bearing wall must stack over <br />/ blocking and wall or beam below.* <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Provide adequate bearing <br />for each lapped joist. <br />(quash block — 10dnails SECTION @ INT. BRG. WALL <br />2x4 minimum) <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam ® �! <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) p <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />6"' A 1Y" ROUND HOLE MAY <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB, PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />DO NOT CUT HOLES <br />LARGER THAN 1Y2" <br />ROUND IN <br />CANTILEVERS. <br />>•R+.+'TY 'F. fi L& �'9iR`I"YY"{q 4 �N <br />p <br />...• t��.Y° p u'l.V*�i�hS�•iY"l. <br />�'u.A RYR+m. y�g�ti En"' i`�„ "s �`Fx,��• 1� =' <br />tE,,:. :..d.._ - .F...�.F. ]� e ,,.E.. I.JJ <br />-•+2dn <br />, <br />,�::t. <br />R'L}��y.}�� <br />C` M1.' Y <br />s'? <br />�q'N`i� <br />'l`r <br />kWp 1�I <br />XrE•tJC?iY .+ j <br />� <br />�yd <br />I;.J d <br />:� i k k< <br />, '+s• <br />bY'i�r.i,. <br />RAN <br />'� T1< �I' <br />ix3 <br />k A <br />� I q <br />.r32.ii5°A{, <br />P �, <br />7`C; �l�Mf <br />wj„F,FP <br />i P.yf ]wM'. <br />d� 4W <br />a 5 <br />�� 'iwt <br />N " �lw�''i <br />ey�� j 1 <br />T <br />�7:R� <br />1 • Rye <br />'y v^p, 54vp' <br />i a�R.ce_. <br />F {� _j(�Nli,�yy^+.1/ <br />) <br />. 8S �k'i' �. <br />'C ,. <br />.Rt µ ' <br />:x.- u' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />ED <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />1/4"-2" gap <br />NI I <br />Top Mount" "Face Mount" <br />Backer Block <br />" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />-- -� requirements <br />0.6 X Joist <br />✓ : depth <br />I III ✓ � I 0 I %iVJ I i,. <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />a• <br />aH ;o <br />FINISH GRADE <br />SLEEVE THRU STEM-/ <br />SEE PLAN FOR--'•. a • <br />FOUNDATION INFO ° <br />STEM FOUNDATION <br />GRADE <br />0 <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A <br />,�; <br />(WHEN <br />w/ (18)10d x 1 1/2" <br />-_"_ <br />REQUIRED) <br />NAILS <br />=- <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />0 1 <br />'' I I TTT • <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />C <br />° 4 <br />• -I 1 f_TTT <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING <br />GILNE <br />in g � • aw • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />- G <br />a _ <br />a ° III I <br />—/ . Tr <br />e <br />SEE FND. PLN. <br />SIZE & REINF. <br />N <br />C`• 1 <br />a rJ <br />\ <br />cn� <br />t y,R <br />U <br />v�ro k <br />• V C LL' ,�. <br />cu r_ J ; a, <br />GY lr <br />R .r cv .n <br />> c � <br />°� <br />rs <br />4Z •- <br />VJ <br />ro <br />� <br />R <br />S <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />.4g <br />E <br />M <br />� y <br />V <br />r 2 <br />0 <br />~ 0 93 <br />N <br />ENO <br />:Ii <br />Q <br />yy M V' SS22z � lL <br />l W <br />C J LL <br />S <br />uL SS a <br />w <br />Z <br />—.6— <br />m qo S <br />L a <br />W <br />O z rn ox <br />W <br />co_ m <br />N Z Q <br />Z <br />N O U <br />W <br />❑ ❑ <br />`= N <br />Z <br />Z O <br />Q, c <br />J <br />N <br />rt <br />f~ <br />� A <br />U <br />Q <br />to <br />u.J 8 <br />c <br />�N <br />01 <br />R— <br />U � <br />LLl � <br />I <br />C_ <br />¢ 8' <br />Qr � <br />S <br />� <br />M <br />m <br />g <br />LL_ <br />z 4 <br />> p <br />z® <br />Q <br />E vca <br />fug <br />na <br />t— <br />o Fgo <br />f <br />�a <br />U <br />z <br />N <br />co L <br />i Y <br />O s <br />co J <br />o <br />i7� <br />>Z <br />f`rn <br />JU <br />a= <br />W <br />w <br />T <br />C <br />c O <br />> Lid <br />O <br />rn <br />m <br />C9 <br />D\J <br />O <br />c T <br />m <br />VJLO <br />4-J <br />00 <br />N <br />C) <br />L0 <br />.0O <br />ai <br />j <br />C`V <br />i6 I- <br />o <br />N <br />zm <br />E <br />- <br />r <br />r <br />C <br />4)Ua. <br />J$ <br />JOB <br />NO : <br />22-08303 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />