Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/6" CEMENT <br />PLASTER - <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK---\ <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY -- �_ <br />//ZATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />= REQUIREMENTS <br />BEAD BRIDGING <br />/ J <br />CLADDING AND WINDOW/! <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />' V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SE <br />DO NOT <br />BOTTOK <br />FLANGE <br />SELF -ADHERED FLASHING Scale: I <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as f # in each detail that corresponds to the <br />numbered items in the list o Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material I x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />WEATHER <br />✓E BARRIER & <br />,ARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN --, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WPI <br />8 2 <br />4SHING <br />rel <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIE( <br />THRESHOLD OF DOOR AP <br />UP JAMB 6". USE LIQUID I <br />OR EQUAL WEATHER PR( <br />SECTION -A (SEE DETAIL WP <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WPI <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SHEATHING <br />IIC <br />DOUBLE 4JOIST <br />:EN= dg�0. <br />SINGLE WOOD BEAM <br />JOIST BELOWSELF-ADHERED FLASHIN3" MI <br />SELF-ADHERED SELF -ADHERED <br />FLASHING FLASHING O <br />2 <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROI <br />8"CMU --- <br />4" OR 8"1 <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />�Jl E <br />1'-4" PER PLAN <br />1'-0" PER PLAN <br />F-7_C <br />A <br />H <br />SHOWER SEAT <br />- DOOR ROUGH OPENING <br />WINDOW UNIT <br />SLOPE <br />FLASHING REQUIREMENTS <br />0.3 in: 12.0 in R703.1 General. E)tterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />- 3/a'-1" BEAD OF CONSTR. (0.6 cm: 30.5 cm) include flashing ds described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID EXTERIOR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER MA PROOF CAULKING CEMT. FIN. water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />SELF -ADHERED FLASHING BUILDING PAPER of draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No 15 asphalt felt shall be applied <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />RIM JOIST No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />--7 R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />2V Q D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />1 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER 111 Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />NEEDED IN CORNERS - RUBBERIZED ADHESIVE <br />STALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />ASHING JAMB &HEAD FLASHING R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />ASHIN WSEEINDOW SELF ADHERED FLASHING applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />NGEEE DETAIL WP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED - prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />_LF-ADHERED FLASHING, ' o (BEFORE FOLDING. SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER TO EXPOSE <br />(TEND A MINIMUM 6" ADHESIVE AS SHOWN) contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />RTICALLY FROM <br />)TTOM <br />F flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />2 shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />1 6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 7 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />M <br />INSIDE CORNER 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />NA I <br />-7Ground7 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 6.6.At wall and roof intersections. <br />- Water Resistant Barrier 7.7.At built-in gutters. <br />SELF -ADHERED FLASHING <br />PATCH <br />SELF -ADHERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER FOUNDATION WEEP SCREED <br />7 .-II <br />I <br />fll` <br />I II --STRIP OF SAF <br />_ , <br />I� <br />F --DRAINAGE PLANE WRB <br />Lu <br />¢ I BOND BREAK WRB <br />> <br />m <br />Q I SF LATH <br />c <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />/ II BARRIER <br />i I <br />1-3 <br />-1/2" INCH FLANGE <br />W LU PLASTER STOP - THIS GAP IS A RESULT OF <br />LU NATURAL SHRINKAGE. <br />(n �- - - - - - - - - - DO NOT SEAL, <br />W CONTINUOUS BACKER - <br />U ROD & SEALANT DRIP SCREED PLASTIC <br />w UJ <br />_ ACCESSORY <br />w W <br />�° A <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) - - <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - <br />BOND BREAK WEATHER RESISTANT BARRIER- -- <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY - <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />II I <br />II; I <br />----- --- ,II <br />ill I <br />Cement <br />Plaster <br />TACKER ROD over block <br />1 st floor <br />FINISH <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />C4 <br />['V <br />r.t <br />w <br />G R1 CJ C") <br />CJ <br />O <br />N Cu7. <br />to N <br />h � <br />3 .= a' <br />� <br />L <br />!2 <br />u a, <br />m E <br />�• u <br />N <br />O <br />CV <br />It- <br />2! <br />ti <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Flonda Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages <br />bearing <br />Engineer's signature and seal. <br />N <br />a <br />E <br />M <br />g o� <br />0 <br />C S <br />� r <br />N <br />in ' r• ° <br />oJe <br />W <br />Q <br />rNi 'T # <br />C J L <br />W <br />mn o <br />Z <br />- d Y <br />l6 C <br />Z Rig <br />o <br />'b�E,Y, o S <br />W <br />Z <br />�' m w <br />ry M Z Q <br />;n <br />O U Cc) <br />Z <br />W <br />❑U0W <br />❑ <br />J OD <br />.' o GQry <br />131 <br />ct �, <br />r <br />M <br />V) <br />B <br />(. <br />v <br />J <br />Ol.�s <br />V)11 <br />� N <br />c� <br />N <br />Im <br />G <br />F <br />m $ <br />L <br />i <br />I <br />= <br />0 <br />U 05 <br />• <br />�tl <br />oZ <br />ccpp <br />w <br />0 3 <br />J <br />I.L.zc <br />a <br />71. <br />1 <br />f <br />�n <br />cu <br />h <br />o" <br />z <br />g� <br />aZ <br />Za <br />CD <br />N t <br />o <br />ww <br />N <br />=jz� <br />Z <br />_ <br />J <br />Tm <br />ob <br />a <br />_ <br />vw <br />t <br />,Z <br />12 <br />LL <br />a, � <br />�W <br />o <br />J <br />to <br />=1K <br />W <br />UI <br />.N Q <br />� <br />> Lo <br />L-L <br />Om <br />0 <br />(0 <br />O <br />T <br />f <br />Q <br />W 0 <br />N <br />oo <br />LO <br />O <br />cy) <br />L , <br />r <br />Q <br />r <br />n <br />6 <br />N <br />o <br />Z <br />M <br />:3 <br />E O <br />`a <br />m <br />E <br />U <br />a; <br />c <br />a <br />Q p <br />_J <br />JOB <br />NO : <br />22-08303 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />