Laserfiche WebLink
P <br />i <br />) <br />J <br />) <br />T <br />) <br />) <br />J <br />3 <br />i <br />J <br />J <br />J <br />j <br />I <br />) <br />T <br />J <br />I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 copper to lights & Outlets <br />NEMA t <br />150 <br />AMP/ #12 copper to 20 amp ckts <br />AM <br />200 AMP #10-2 copper to WH <br />#10-3 copper to Dryer <br />n2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#—f[4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1.5" VTR III <br />I� <br />I <br />I <br />I <br />I r\ <br />I I /> <br />I \\ I /' <br />� i I <br />I I I I <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />PLUMBING <br />RISER- <br />P.C. <br />FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACKLIGHT <br />LIGHT <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />FLUORESCENT LIGHT FIXTURE <br />BE VERIFIED WITH PLUMBER <br />Q <br />EXHAUST FAN <br />SWITCH FOR DISPOSAL <br />;�� <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />- - - -GFI <br />f ® <br />PUSH BUTTON SWITCH - DOOR BELL <br />j <br />11 <br />O <br />I <br />GFI <br />SD <br />SMOKE DETECTOR <br />I <br />- <br />® <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />GFII <br />/ <br />IGFI <br />TELEPHONE (OPTIONAL) <br />_ <br />i <br />2 X 4 FL. / <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />- <br />GFI1 <br />I <br />I <br />KITCH ESN <br />I <br />F <br />TELEVISION (OPTIONAL) <br />_ <br />❑ -V 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />_ <br />_ <br />= <br />I <br />I <br />DEDICATED <br />RECEPTACLE <br />O <br />THERMOSTAT <br />I <br />I FOR MICROWAVE <br />ELECTRIC METER <br />I I <br />... � <br />- - - <br />IGFI RANGE HOOD <br />PER SPECS <br />ELECTRIC PANEL <br />===,J <br />3 I I <br />DISCONNECT SWITCH <br />^_Enj <br />J <br />ROUGH -IN FOR OPT. CEILING FAN <br />G <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE'LINE, (1) DATA PORT <br />1 <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />TT Y <br />r- - - - - - - - - - 4 <br />I <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ I I <br />;LIGHT PRE -WIRED <br />BEDROOM 2 <br />I I I <br />I I I <br />I I I <br />----------- <br />I I <br />It <br />I <br />I <br />I I <br />I <br />I I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET— <br />r_===—i <br />IIf _1I <br />II ALT II <br />AC PAD I I <br />L=====1J <br />WP <br />GFI 4 <br />DISC. <br />H <br />w3 <br />0 0 <br />crU1 <br />>Zim <br />PER SPECS <br />ELECTRICAL PLANS - ELEV-A <br />SCALE: %4'=1'-0" <br />o <br />o <br />CV <br />Z <br />�t f_ <br />LO <br />+r <br />rS <br />_LILC C <br />M V O <br />a <br />>> <br />tl4—w <br />N <br />0 <br />N <br />N <br />N <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0) <br />f <br />$ <br />Q <br />o I <br />N C7 N 4 � <br />C W J LL <br />W <br />�Nro LL a. <br />M LL LL a S <br />a <br />ul <br />J <br />�-� 0,O <br />�o' c c C p s <br />" <br />Z <br />ML <br />IL L <br />a <br />00 N M Z W N O <br />O U U coo <br />Z <br />W <br />�El 11 <br />cD c <br />) <br />Z mN CQQ7 <br />Z pp W <br />z <br />J <br />1 ^ <br />' <br />N <br />M <br />Z <br />o <br />. <br />W N <br />� a <br />U <br />0 <br />W <br />v C <br />Lr J <br />r g <br />z® <br />U <br />_ <br />0co <br />o <br />co <br />J <br />Z` <br />w <br />Z <br />i <br />J <br />❑22 <br />i o <br />f0 <br />)Z o <br />QN <br />�z <br />❑a <br />E <br />ao <br />❑g <br />Z <br />O <br />O @ <br />cv <br />i <br />az <br />wg <br />8 <br />ao <br />WZ <br />auml <br />.N- <br />Mr <br />Cl)C <br />o <br />mf <br />p <br />oLL <br />Z <br />__ <br />� J <br />ym <br />� ,sg� <br />a� <br />N <br />0-3 <br />op a <br />w <br />Z�a1 <br />Z <br />w <br />W <br />��; <br />IT <br />�� <br />J <br />o <br />JW <br />w` <br />�_ <br />� <br />w <br />a <br />oi3 <br />i°d <br />C <br />0 <br />T <br />1 <br />>� <br />J <br />L1 / <br />O <br />N <br />rn <br />CM <br />co <br />I <br />N <br />a <br />CT <br />W m <br />N <br />� <br />o <br />L0 <br />N <br />r <br />Q <br />N <br />r <br />m <br />co <br />N <br />iri N <br />o <br />Z <br />Z <br />E N <br />�o <br />` <br />a <br />E <br />U <br />JOB <br />NO : <br />22-02369 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />