My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6359 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6359 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:35:14 AM
Creation date
2/19/2025 8:52:49 AM
Metadata
Fields
Template:
Building Plans
Street #
6359
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5288
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV - ABOVE MLDG - MOULDING THE FOLLOWING TECHNICAL CODES SHALL APPLY: VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />AFF - ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING 1.0 CLIENT CHANGES CS COVER SHEET N <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, Al FOUNDATION PLAN N <br />O A/C -AIR CONDITIONING MUNT - MUNTINS 2.0 FLORIDA BUILDING CODE 6TH EDITION (2017) UPDATED <br />ENERGY EFFICIENCY, ACCESSIBILITY, NFPA 70 NATIONAL ELECTRICAL CODES 2017 A2 1 ST AND 2ND FLOOR PLAN c14 <br />ALUM - ALUMINUM # -NUMBER n <br />AT -ALUMINUM THRESHOLD OC - ON CENTER 3.0 MASTER CHANGE UPDATE A2.1 SALES OFFICE PLAN <br />AB -ANCHOR BOLT OGD -OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 A3 STAIR DETAILS �_ - I'_ o <br />1. TANK TYPE WATER CLOSET VOLUME 4.0 PERMIT COMMENT REVISION A4 2ND FLOOR - ROOF FRAMING PLAN ;�,+ <br />?Ne <br />�oAVG -AVERAGE OPNG - OPENING W 1.6 GALLONS A5 EXTERIOR ELEVATIONS & ROOF PLAN LO <br />LO <br />BFE - BASE FLOOD ELEVATION OPP - OPPOSITE 5.0 TRUSS CONNECTOR REVISION R ;.'' %,','p ` ` <br />BM -BEAM OPT - OPTIONAL A6 1 ST & 2ND FLOOR ELECTRICAL PLANS <br />BLK -BLOCK OH - OVER HANG 2. WATER - FLOW RATE. 6.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATED A7 INTERIOR ELEVATIONS ��2 Q <br />BLDG - BUILDING OH CABS- OVERHEAD CABS PUBLIC FACILITIES LAV 0.5 G.P.M. SNO STRUCTURAL NOTES' <br />- ••'' 7.0 UPDATE DETAIL CALL OUT FOR 2ND FLOOR WINDOW AT BEDROOM 5 �.� w <br />BRD -BOARD PNT - PAINT FINISH PRIVATE FACILITIES LAV 2.2 G.P.M. SN1 STRUCTURAL NOTES <br />BRG - BEARING PTD - PAINTED SHOWER HEADS 2.5 G.P.M. 8.0 ADDING K, L, M ELEVATIONS S3 FOUNDATION DETAILS '•*'•• ARGOi3 •��_ <br />BTM -BOTTOM PF_D -PEDESTAL S4 FRAME WALL DETAILSO <br />BUC - BUILT UP COLUMN PERF -PERFORATED �S ' . , , - • ., <br />3. ALL PLUMBING WATER LINES S5 STRUCTURAL DETAILS J' � <br />CAB - CABINET PLT -PLATE BC <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC S6 WALL SECTION DETAILS P-0 A <br />w <br />CLG -CEILING PKT -POCKET VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO SS RETRO FIT DETAILS Ix <br />CLG HT - CEILING HEIGHT LB -POUND ST STAIR DETAILS z <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S11 PRECAST DETAILS <br />Q <br />CL - CENTERLINE PSI - POUNDS PER SQUARE S12 PRECAST DETAILS <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.0 PRODUCT APPROVAL <br />CONC - CONCRETE PB - PUSH BUTTON CODE PA 1.1 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR ❑ PORCHES AND BALCONIES PA 1.2 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE CHAP. 3 PA 1.3 PRODUCT APPROVAL to N � CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING > o K 0 <br />CTR -CENTER REQD - REQUIRED <br />CJ - CONTROL JOINT R/A - RETURN AIR SH 1.1 HURRICANE SHUTTERS 0 M M <br />/r HANDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS M m <br />t' DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.2 HURRICANE SHUTTERS �- p U <br />DTL - DETAIL RS - ROUGH SAWN ❑ GUARDRAILS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS to F -0 co t o <br />,6 DIA - DIAMETER SC - SOLID CORE SH 1.4 HURRICANE SHUTTERS � O 2 0 <br />DIM - DIMENSION SCP - SCUPPER STAIRS - CHAP. 3 <br />_� O 8 ° Q <br />DISCON -DISCONNECT SCRN -SCREEN t U <br />H 1.5 HURR ANE NUTTERS <br />DW -DISHWASHER SIM -SIMILAR ❑ CHIMNEY & FIREPLACE .N V LU O C <br />WP 1.0 WATERPROOFING DETAILS O � � � <br />DR -DOOR SHLVS -SHELVES CHAP. 10 a L o E <br />DBL - DOUBLE S/R - SHELF & ROD a �C_) o _0 <br />DWG - DRAWING SH - SINGLE HUNG WINDOW EGRESS WINDOWS <br />EA -EACH SGD - SLIDING GLASS DOOR ❑ <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV - ELEVATOR SQ FT - SQUARE FEET 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQ -EQUAL SQ IN - SQUARE INCH BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EQUP - EQUIPMENT STD -STANDARD GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />EXP JT - EXPANSION JOINT STL -STEEL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />EXT - EXTERIOR STRUCT -STRUCTURAL <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR - FLOOR TP - TOILET PAPER HOLDER 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FLOUR - FLUORESCENT TYP - TYPICAL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS <br />FR DR - FRENCH DOOR VAC -VACUUM w � w _j w w o� o <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR W W w p ¢ Q 2 J ¢ - z 0 z <br />GA -GAUGE VERT - VERTICAL TO BE TEMPERED GLASS. (SECTION R308) U a o x J `� W o o o <br />GB -GRAB BAR VIF -VERIFY IN FIELD j F' OWO0wZZwwZ�UZ=QQ <br />Sao o�oom z <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR - VENT THROUGH ROOF DIMENSIONING: O O w a > cn w w in w W z O <br />GLS -GLASS V -VOLT O Z Q�< WgFnKwz��, a. <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET A. DIMENSIONS INDICATED ARE TO: o wx o ? o z <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER w Q O ►- a w <br />A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HD - HEAD WL - WIND LOAD A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF CORE -STUD <br />HT - HEIGHT WWM - WELDED WIRE MESH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. It <br />HB - HOSE BIB W - WIDE OR WIDTH FURRING\ C)HC - HANDICAP WDW - WINDOW C)INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD N <br />INT - INTERIOR WD - WOOD A.4. WINDOW OPENINGS: z W <br />LVL - LAMINATED VENEER LUMBER A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING 0 W <br />LT - LAUNDRY TUB A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />LGT - LIGHT A.5. DOOR OPENINGS: (0 5 r-- <br />MAIL - MAXIMUM MATEAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING > � q O <br />A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />MFR -MANUFACTURER 0 i,_ M O <br />MECH -MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED Q M � <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR _1 <br />MC - MEDICINE CABINET FRAME I W LL_ <br />MIN - MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTERLo <br />OF DOOR < a M <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH a• �- <br />SURFACE TO FINISH SURFACE Q }- Q 00 <br />SYMBOL LEGEND. A.6.1. EXAMPLE: T-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER z V F- <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND z <br />= STAIR CALL OUT - HEIGHT OFHEET NUMBER PLUMB. LU W <br />-STEP DOWN AlA13E-- C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: J O <br />1 IC)NT ELEV NUMBER C.1. CODE MINIMUM -MAXIMUM DIMENSIONS AND CLEARANCES FOOTING CALL OUT - C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS Cfl <br />STEP DOWN ARROW SHOWS <br />AO = SEE FOOTING SCHEDULE CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR miARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />O = KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - N <br />ELEV NUMBER UNLESS OTHERWISE NOTED o <br />A9 ARROW SHOWS <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE ti <br />qO = OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED N <br />SCHEDULE ELEVATION MARKER All SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE 11 <br />STRUCTURAL MATERIAL ABOVE AS SCHEDULED C)1 F ELEV NUMBER SHEET NUMBER G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LG-2 LEDGER CALL OUT - SEE SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 <Al5 2 COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE O <br />__ARROW SHOWS LOCATION OF CUT DRAWINGS. c6 <br />C)r r <br />DIRECTION OF VIEW (0 00 C) C) C)r N N N N N <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER C) C) C) C) C) C) C) <br />N N N N N N N <br />00 M r O <br />N N G_- O N CM <br />O O CO <br />O O O r r O O <br />C <br />NV, ON MV-1 L0 CO ti <br />OCT 18 2022 Lo d. <br />VV\ 1 Cr z z <br />CO u) z <br />Virtual Review Assist, Inc. O -1-�+ O w co <br />Plans Review completed and approved O U o ~ o <br />L N NARSIM for compliance with the 2020 FBC 7th Edit' 0 <br />Q <br />by Debra Anne Klahr PX2300 ~ W w 2 <br />-0 U) z w <br />Q =moZ <br />LENNAR TAMPA DIVISION Q �z L W <br />4600 W CYPRESS ST SUITE 200 0 la �¢W0 <br />� Mzx <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS <br />TAM PA FL 33607 cv W �`' a W <br />U�ZCD <br />813.574.5700 IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE z = Q z <br />BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING Z F- O <br />U <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT z <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O Q <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR z <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE C S Z <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z W <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION N <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE W O o <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE LAST PLOT DATE <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE 2382May. 2, 22 <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND O <br />APPROVAL BY THE DESIGN PROFESSIONAL. 0 COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.