6359 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6359 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:35:14 AM
Creation date
2/19/2025 8:52:49 AM
Metadata
Fields
Template:
Building Plans
Street #
6359
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5288
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4" = 1 1 <br />-01 <br />1 <br />I wr e%r n^ter <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLF. FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN N.-PA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />OCT 1 8.2022 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approv <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Ktahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />9 <br />SWITCH <br />° <br />4 1/2" <br />DOORJAMB <br />DUPLEX 9 <br />OUTLET i <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />0 110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—� DIMMER SWITCH AT 36" <br />—� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />{}}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-{} SURFACE MNT FIXTURE <br />-{ WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />,8 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />{} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />°U-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F_m24:R 24" VANITY LIGHTING <br />159_�36:FR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FANLIGHT <br />Q EXHAUST FAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />IM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />INg—ft] ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />® A/C REGISTER <br />® THERMOSTAT <br />EM SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />N <br />0 <br />N <br />N <br />Ln <br />r :J' <br />DOp M` <br />LO <br />00 <br />a <br />w <br />W <br />0 <br />z <br />Q <br />N <br />^' <br />N L0 E <br />> o O.' � <br />V/ <br />L 'c �O r? v <br />M 64 5 <br />4— <br />. <br />M <br />E co <br />W <br />oQ <br />_O <br />0 g N <br />t Ua� <br />•nN, <br />V <br />00 E <br />W <br />L �2 <br />�Co 'D <br />LLI <br />IJA uS w O f- <br />wFw-~ W R YZCr Z <br />(7 W <br />Q <br />Ix aZ)--1W03:W 0LLUOL�O <br />Z LL LL <br />6 <br />a Q O <br />O Z <br />a w�oZOR00mZZ <br />�Waa,��xwwWv�LLLra0Wa <br />(A LL <br />Q►a-a0wau�ZwZowUo� <br />Ow �~� mwap <br />= <br />OQ <br />LL OO�aw <br />O <br />Z <br />W <br />OI_ <br />(1) D <br />M O <br />COQ L0 <br />2 <br />LL ti <br />LLI I.q <br />H�a.('M <br />Q 000 <br />Q <br />Z U <br />Z <br />LU <br />WO <br />J <br />O <br />N <br />N <br />O <br />N <br />r <br />N <br />O <br />O <br />co <br />O <br />COo0 <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />�- <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />o0 <br />O <br />ob <br />O <br />A <br />D <br />N <br />O <br />cM <br />N <br />0 <br />0 <br />0 <br />O <br />O <br />r <br />o <br />O <br />0 <br />C <br />N Lo <br />; <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />LO Mt <br />I- <br />N <br />M <br />O <br />O <br />P <br />r <br />MI <br />w <br />z z <br />Z O <br />W <br />O40 <br />W fn <br />Uo�o <br />_ <br />F_ <br />0 <br />ZWF- <br />XWM <br />Q <br />~ <br />IY <br />F_MOZ <br />N <br />29 <br />Z 3: —1 <br />00 <br />W}W2 <br />�-Mz° <br />M <br />13L.zZ'L <br />CV <br />W N <br />0 <br />2 z <br />r— <br />Q <br />VLnzczn <br />. <br />Z <br />x < 0 <br />Z <br />U <br />U <br />� <br />O O <br />a <br />W <br />� <br />z <br />a <br />Z <br />z <br />w <br />N <br />N <br />WC) <br />0 <br />r— <br />LAST PLOT DATE <br />.. <br />May. Z 22 <br />Z 0 <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />