Laserfiche WebLink
{�IN41f lI I A�lI)fl�lellll � 1�r1AI�11A"MIT1WRTTog*I 1���R11A! �R'F*�ATl�sRR�1�l4R��Ir11�11AIeR� A �I�ROIIA� � <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4" = 1 1 <br />-0" <br />A/C <br />f "ANIVIA <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-011 <br />1 1\IC' PIP' I7 ^1 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK, <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />AUG 0 3 2022 <br />V' /\ <br />viATi ., t, t ,EW ASSIS I <br />Artuat' Review A:s �`, Inc. <br />Plans R,�:v;_­/v i ornpiutpo and a �,o ed <br />for con piai Ice W J) the. 2020 <br />Edition by Deora Anne Klan; IJ' 3�50 <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET M <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o <br />9C_'S.MOKE <br />DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />_.+ TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />6- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />{} SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />40W A " ROUND OPALEX - ALTERNATE <br />CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />cs SMOKE COMBINATION <br />ORBON MONOIXED DETECTOR/ <br />DETEC SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24- UNDER CABINET 24" <br />=S-24- SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 - DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />IF 24 :�a 24" VANITY LIGHTING <br />&67u_u 36 � 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />(, EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />p�p DOUBLE FLOOD LIGHT W/ COVERS AND <br />�J 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />» ELEC PANEL <br />M VACUM OUTLET AT 12" <br />IZICEILING RETURN AIR <br />® A/C REGISTER <br />QT THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />E <br />UU <br />�L r <br />i <br />4) <br />� E 2 S <br />Uag < <br />�N w Qv <br />^, U N C <br />�O E <br />W L ri m <br />a a <br />W (� <br />oLU w CO w0H <br />LU 5 aa <br />0it-_j 0 <br />0DZ< <br />aX��c0z20CHQ� <br />Z0Z=wO00caCY <br />2zit¢0 <br />o 0 <br />Z <br />LLa <br />_jRazaZjOw0. <br />_j<LLIuu a. <br />o�W <br />QLLOQ <br />O <br />Z W <br />0F_ <br />55 Z) ti <br />O <br />C <br />U) CM � <br />Q <br />L.L <br />w P <br />IfIZCM <br />�a'2T- <br />Z U <br />e W <br />J O <br />F <br />CEO <br />N <br />N <br />O <br />CV <br />; <br />ti <br />N <br />O <br />O <br />06 <br />W <br />�- <br />00 <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />0) <br />N <br />00 <br />O, <br />U) <br />00 <br />O <br />M <br />T- <br />N <br />O <br />eM <br />M <br />4 <br />O <br />, <br />O <br />0 <br />O <br />0 <br />0 <br />r <br />— <br />0 <br />C0 <br />0 <br />C <br />LO <br />j <br />0 <br />0 <br />N <br />M <br />0 <br />'T <br />0 <br />V) <br />0 <br />(O <br />0 <br />r- <br />e- <br />z z <br />O <br />OLU <br />owuo <br />0 <br />V_o�o <br />O Q <br />LO <br />(l) <br />0 <br />11 <br />w � Q <br />F—LU0 <br />tV <br />O w <br />z� J <br />M <br />y-2ZW <br />aZzLL <br />(� <br />Lu (V <br />OgMz <br />V�zco <br />. <br />Z <br />F_a0 <br />Z <br />U <br />0 <br />0 <br />O <br />a <br />M—M <br />W <br />o: <br />Z <br />A6 <br />z <br />z <br />w <br />J <br />N <br />N <br />LU <br />M <br />LAST PLOT DATE <br />>r <br />a 0 <br />Apr. 25, 22 <br />z <br />0 <br />1ST & 2ND FLOOR <br />� <br />J <br />ELECTRICAL <br />PLAN <br />B <br />