Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />I'I <br />... I—'ik........... <br />......� . .......... <br />:....... ... <br />:: }.........I ..... <br />........... <br />16GAx1-1\2" LONG (3/4%1" CROWN) 8 . 1.. <br />MAX. 16GAx1-1/2" LONG /4„-1" <br />STAPLES @ 6 O.C. VERT BETWEEN ...... I ............ (3 <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />"DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH' <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />0 O 0 <br />5'-0" ¢ - <br />0 <br />STUB -OUT FOR 1'-0" = o is <br />0 <br />GAS METER 9 U <br />o <br />N oz <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />F-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />1114" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI8Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 112" <br />6500s 1.8/1.7 <br />,,,rood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />AHOOK� <br />STD. 900 HOOK BOND BEAM <br />w <br />¢ CONT. #5 <br />CONT. #5 �� BAR <br />i CONT. <br />iOM <br />)UNDATION <br />HIGHEST <br />)ND BEAM <br />ovf�v ocr•�tvt � t �r <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION "'INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" m <br />ax. 4 max. <br />A <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3} Leave 1!8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4} Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top irdsmouthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor coh rmn w/ In;A z <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />'Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* --� <br />�Z1 Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Squash block) 10d nails SECTION @INT. BRG. WALL require additional consideration.- <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />6" A 1 2' ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />11-01 <br />1'-111 <br />1 2' <br />1-2'° <br />V--3' <br />1'-3 <br />9'-71 <br />fi'-i t•' <br />2-41 <br />"1 <br />1 3- " <br />3 71 <br />Arliy 16" joist <br />12 <br />1 <br />1'-3 <br />i= <br />2-4" <br />2-11," <br />3'7" <br />4'Z" <br />4'-°5r-, <br />m <br />16 <br />1-0" <br />1'-1" <br />2" <br />1- 7" <br />2 <br />3'-2 <br />3'-10" <br />4'-0 <br />57 <br />6C' <br />72' <br />20 <br />I'-U' <br />1-1"Z' <br />11�11V!-2" <br />2- " <br />8' U' <br />4,-C' <br />4'-10" <br />6-11"24 <br />'-{)'°1'-1,°r <br />2'-g' <br />8 7" <br />4'- <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1 2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web StiffenerFastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />I 5- d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />_,1 _7/8 <br />1-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) ' <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />1.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12/ <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) -1 I I — <br />Nail with 10-10d nails. ' <br />Install tight to top flange. SLEEVE THRU STEM 4 <br />SEE PLAN FOR °• <br />el FOUNDATION INFO ` 4 <br />STEM FOUNDATION <br />f GRADE—ovrArr OCC or nKr <br />\ Filler block, <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />AV1/4"-2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hang(e,doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />i <br />I -JOISTS BUCKETS <br />N.T.S. <br /><+ rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A 1 e .0 (WHEN <br />w/ (18)10d x 1 1/2 REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />TOP (2) #5's x 4'-0" <br />—\ <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />q L <br />4 <br />� '4 ' 4 <br />-L-Y <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a <br />44' 4 4° G <br />4. 4. 4 4-1 I i— <br />T� <br />SEE FND. PLN. <br />SIZE & REINF. <br />C" <br />o <br />1 <br />_ <br />as W <br />7 <br />4- <br />s <br />M <br />Cc C0 x <br />w a- <br />' <br />y <br />CZ <br />t y O <br />3¢�g <br />d <br />� E <br />0 <br />Vk <br />rb <br />r•., <br />\ N <br />p4. <br />Spy` 10 x� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />h <br />of <br />0 <br />(0 U <br />C. N <br />C? <br />44 <br />W <br />at <br />Q <br />� � <br />W <br />o <br />Z0 <br />JLL� <br />ui <br />f 2 o <br />i <br />5 '?a N r2 0 <br />Z <br />"z <br />Z <br />N C 0 U <br />U) <br />W <br />❑❑ <br />,a <br />z � o <br />z <br />Co <br />Iola <br />z ti <br />¢ Q <br />J <br />r <br />to <br />M <br />z <br />(D <br />a-1 <br />(0 <br />� <br />W, U <br />O <br />o <br />W'N <br />w <br />�in <br />X <br />In <br />CJ <br />LU <br />map_ <br />E <br />r 8 <br />` <br />V o N <br />¢ N 0 <br />sm <br />o <br />Z <br />z <br />coo <br />L <br />r r_ <br />sz E <br />o <br />� <br />W o <br />g <br />Z <br />Z0 <br />oa <br />(6 V <br />�0 <br />XU <br />&a <br />Ut. p <br />�U <br />O E <br />O <br />'0 <br />zo <br />o� <br />a Z <br />L <br />CQG. <br />¢ O <br />qz <br />m <br />rp <br />zz z <br />OY <br />o <br />Z <br />z <br />- v <br />�m <br />¢w <br />Cn <br />3 <br />F <br />z <br />ao <br />N <br />oa <br />U <br />ao <br />Nod <br />Z <br />=3 <br />oJ <br />Ilflflflflfl� <br />O <br />w <br />0 <br />a <br />L 0 <br />LOrn <br />L <br />Q <br />� <br />� <br />M <br />:3M <br />O <br />]C <br />m <br />m <br />LN <br />r Q <br />N <br />0) <br />I <br />N <br />O <br />O <br />N <br />r <br />L <br />r <br />� coy <br />o <br />Z <br />ca <br />C <br />T <br />c <br />m <br />0 <br />ui <br />W <br />a <br />0 <br />Q o <br />JOB <br />NO : <br />22-06466 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />L— oar :u d;�u�� . .,. ,i,', a �.cni.:,i,, , n <br />r <br />