Laserfiche WebLink
SPECIFIC NOTES: <br />PREPARED BY <br />r <br />I <br />J /1 <br />y ilk F <br />---- - - <br />R <br />t <br />I <br />I <br />I <br />k <br />ja <br />� <br />i <br />I <br />A A-5 - A-3 MOUNTED ON POST <br />i II t <br />F <br />n - ��� P g <br />' WP � _ , <br />l_ _ F _,fir► A-1 <br />F✓- <br />METER ATr <br />I I � <br />s <br />I I � <br />I <br />I I <br />I <br />I <br />I <br />I <br />G <br />1 Power Plan - Heavy Timber Structure 'A' <br />I <br />I � <br />4 <br />'i METER C <br />C I <br />C-5 I <br />WP I <br />MOUNTED ON POST I <br />P' <br />\� % F C-3 <br />W C-1 <br />C / i <br />/ I <br />>� <br />f / I <br />p I <br />r � <br />� I <br />u <br />?, I <br />I <br />I <br />I F i <br />g METER B e <br />_ I <br />E � a <br />a <br />9 - B-5 I <br />i W I <br />I - MOUNTED ON POST 9 <br />I � I <br />I A F W I I <br />-- <br />I B-3 i <br />77 <br />Power Plan - Heavy Timber Structure 'B' <br />1 /8"=1'-0" <br />i <br />/ <br />D-5 <br />S <br />IF <br />r x <br />D-101 I <br />�x ,7 <br />7 <br />1A{P <br />I � , <br />K / <br />/ <br />i <br />I I <br />1. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED AT FREEBOARD OR HIGHER. THIS IS <br />BASE FLOOD ELEVATION PLUS TWELVE INCHES. CONSULT OWNER OR CIVIL ENGINEER OF <br />RECORD. <br />2. ALL WORK ELECTRICAL WORK MUST BE IN COMPLIANCE WITH N.E.0 2017, FLORIDA <br />BUILDING CODE 2020, 7TH EDITION, LOCAL ELECTRIC COMPANY AND AHJ. ELECTRICAL <br />CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH THE SCOPE OF WORK <br />BEFORE BIDDING ON THIS PROJECT. <br />3. ALL GROUNDING AND BONDING MUST BE IN COMPLIANCE WITH NEC ARTICLE 250 AND AHJ. <br />4. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME OF DESIGN. <br />VERIFY ALL EQUIPMENT NAMEPLATE DATA BEFORE ORDERING. <br />5. ALL ELECTRICAL WORK FOR FABRICATED EQUIPMENT SHALL BE COMPLETELY WIRED BY <br />THE EQUIPMENT MANUFACTURER TO A JUNCTION BOX OR PULL BOX, AND ALL ELECTRICAL <br />WORK FROM PANEL BOARDS TO BE BY THE ELECTRICAL CONTRACTOR. <br />6. TYPEWRITTEN CIRCUIT INDEX SHALL BE AFFIXED INSIDE SURFACE OF PANELBOARD DOOR, <br />CLEARLY INDICATING AREA AND LOAD SERVED BY EACH BRANCH CIRCUIT. <br />7. ELECTRICAL CONTRACTOR SHALL FURNISH ALL ELECTRICAL MATERIALS TO COMPLETE <br />THIS PROJECT. <br />8. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND <br />INSTALLED ON ALL PANELS AND SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF <br />PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. <br />9. WHERE THE ENCLOSURE OR RACEWAY IS SUBJECT TO PHYSICAL DAMAGE, THE <br />CONDUCTORS SHALL INSTALLED IN ELECTRICAL METALLIC TUBING, RIGID METAL CONDUIT, <br />INTERMEDIATE METAL CONDUIT, RTRC-XW, SCHEDULE 80PVC CONDUIT, OR EQUIVALENT. <br />10. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL POWER <br />COMPANY AT THE SITE PRIOR TO CONSTRUCTION. AT THAT TIME, THE CONTRACTOR SHALL <br />COORDINATE ALL RELATED WORK WITH THE UTILITY COMPANY'S RESPONSIBILITIES TO <br />MEET THE OWNER'S. <br />11. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, <br />RIGID GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. TYPE 'NM', 'MC', ELECTRICAL <br />NON-METALLIC TUBING, & FLEXIBLE METAL CONDUIT MAY BE USED FOR BRANCH <br />CIRCUITING AS ALLOWED BY THE N.E.C. & AHJ. MAXIMUM NUMBER OF 120V CIRCUITS <br />ALLOWED IN A COMMON CONDUIT SHALL BE SIX (6). THE CONTRACTOR SHALL STRICTLY <br />CONFORM TO THE N.E.C. REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND <br />CONDUIT FILL. <br />12. WORK WITH LANDSCAPE DESIGNER/GC/LANDSCAPE INSTALLERS TO ENSURE LIGHT <br />FIXTURE IS AT RIGHT LOCATION. SEE LANDSCAPE DESIGN PLANS. <br />13. ALL CONDUCTORS SHALL BE THHN/THWN TYPE. UNLESS OTHERWISE CONDUCTOR SIZE <br />NOTED ON THE PLANS SHALL BE 2#12 THWN COPPER AND 1#12 COPPER GROUND IN 1/2"C. <br />MC CABLE CAN BE USED ONLY IN AREAS ALLOWED BY NEC ARTICLE 330. <br />14. EXTERIOR DISCONNECTS SHALL BE NEMA3R RATED. INTERIOR DISCONNECTS SHALL BE <br />NEMA1 RATED. ALL DISCONNECTS SHALL BE HEADY DUTY TYPE. <br />GENERAL SCHEDULE <br />CALLOUT <br />SYMBOL <br />VOLTS <br />AMPS <br />KVA <br />CIRCUIT <br />CALLBOX <br />0 <br />120V 1 P 2W <br />5 <br />0.6 <br />F-7 <br />GM-1 <br />0 <br />120V 1 P 2W <br />9.8 <br />1.18 <br />F-15 <br />GM-1 <br />® <br />120V 1 P 2W <br />9.8 <br />1.18 <br />F-9 <br />GM-1 <br />® <br />120V 1 P 2W <br />9.8 <br />1.18 <br />F-11 <br />GM-1 <br />® <br />120V 1 P 2W <br />9.8 <br />1.18 <br />F-13 <br />IRRIGATION WELL <br />PUMP <br />�,. <br />240V 2P 2W <br />28 <br />6.72 <br />E-1,3 <br />IRRIGATION WELL <br />PUMP <br />�-� <br />240V 2P 2W <br />40 <br />9.6 <br />F-2,4 <br />RECEPTACLE SCHEDULE <br />CALLOUT <br />SYMBOL <br />VOLTS <br />FEATURES <br />DESCRIPTION <br />QUANTITY <br />GFCI_WP <br />120V 1P 2W <br />WP, GND <br />DUPLEX RECEPTACLE 120V. 20A WITH <br />13 <br />GROUND FAULT INTERRUPTING DEVICE. <br />WEATHERPROOF <br />ELECTRICAL POWER DESIGNS <br />P.O.BOX 272517 TAMPA, FL 33688 <br />TEL 813-600-5136 FAX 813-425-4882 <br />E-MAIL: caHos@epd-fl.com <br />CARLOS M. ORAMA, PE. <br />ELECTRICAL ENGINEER <br />PE #60205 CA #27385 <br />ISSUE REVISIONS <br />CLIENT <br />Winward Building <br />Group <br />PROJECT <br />Abbott Square <br />ADDRESS <br />Simons Rd <br />Zephyrhills <br />Florida <br />SHEET NAME I <br />Power Plan <br />JOB # BY <br />E21-250 MAI <br />ISSUE DATE <br />12-15-21 <br />SCALE <br />AS SHOWN <br />THESE PLANS MAY NOT BE COPIED OR <br />MODIFIED WITHOUT WRITTEN PERMISSION <br />FROM THE ENGINEER COPYRIGHT R <br />M. <br />C.ENO <br />� I <br />� i1• � <br />' J�i: CNLW <br />.. -- OF K/ <br />i0 8T of <br />CARLOS M. ORAMA, PE <br />NOT VALID UNLESS SIGNED & EMBOSSED BY <br />A REGISTERED ENGINEER <br />3 Power Plan - Heavy Timber Structure 'C' <br />Power Plan - <br />1/8 =1'-0" <br />Timber Structure 'D' <br />-li i . ----------- Y - _ - -. <br />SHEET <br />E100 <br />