My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6727-6751 Ripple Pond Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6727-6751 Ripple Pond Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:48:24 PM
Creation date
2/19/2025 8:55:59 AM
Metadata
Fields
Template:
Building Plans
Street #
6727-6751
Location
Ripple Pond Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
5203-5571
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4%1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF U <br />HOME H C G <br />GARAGE SIDE 00 O <br />5'-0" o <br />STUB -OUT FOR 0 1'-0" o o <br />GAS METER .t 0 <br />N = <br />• LOOR <br />MEASUREMENTS ARE FROM FINISHED F <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'4" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'4" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'4" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />151-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />*TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />5000s 1.8/1.7 <br />3/4" orp nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking fi <br />r <br />1/8" gap—i 1 <br />x <br />FILL CELL STD. 90° HOOK BOND BEAM <br />11 SIMPSON MGT <br />(ft=— 11 t w/(22)10d <br />LU NAILS TYP. GIRDER TRUSS <br />w <br />a STD. 90° CONT. #5 <br />BAR —� > I HOOK I�7 BAR "vanF <br />2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND � <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8"min. 2" min. <br />)Small <br />2" <br />gap <br />max. � 4 max. <br />Q <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection.7 <br />2) Block solid between joists for full length of span. Tight fit ___ <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top irdsmouthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />1 /16 <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) —J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />I lse 3" /10d1 nails at 6" n.c. <br />U Provide adequate bearing <br />for each lapped joist. <br />odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NV nvLr=o trn�."17 i MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES —\IT D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />6. (see table below) <br />DO NOT cut, notch <br />or drill flanges <br />(D ❑171 <br />iD <br />6" A 1Yz" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End I Intermediate <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />1T <br />' 2-8d <br />5-8d <br />BCI6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />1 2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d -- <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />I 5-16d <br />16" <br />6-16d <br />6-16d <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or J <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* 4 — — <br />Joist <br />When joists meet over wall, provide <br />1 314" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at Vo.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />AN ROUNDED P T THE NEAREST TABLE SPAN. SCAN ACROSS <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN OUN U 0 S <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE iy" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />5/8" 0 <br />THRU <br />BOLT <br />I.0 <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) D.- <br />Nail with 10-10d nails. I I F= <br />Install tight to top flange. SLEEVE THRU STEM r. <br />° �• <br />SEE PLAN FOR °. a ...:. <br />"i FOUNDATION INFO ' a <br />STEM FOUNDATION <br />y \ Filler block. <br />Nail with <br />10' 10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />i <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />o 0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />° <br />r—REINF. SEE PLAN <br />LAIC CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A - <br />" (WHEN <br />SIMPSON H10A a REQUIRED) <br />w/ (18)10d x 1 1/2 <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPE <br />PENETRATION PLUMBING LINE <br />co �� • ° <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />° d <br />d ° ` 1=� <br />°. ° ° —I11 <br />° <br />SEE FND. PLN. <br />SIZE & REINF, <br />ti <br />NO3 <br />11- a - <br />C - <br />U W <br />a � <br />• <br />W a <br />C�_ <br />N <br />N <br />N <br />0 <br />M <br />`'t�t,,tEtt33;r;3�,R <br />CID <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 n <br />W S <br />aO B Nc�p it <br />N 6 C1 S J LL <br />a _ �� ' CO 'CoeJu-u- <br />(L 3 <br />cr <br />13Z -a e 3. o <br />r Co o O �- <br />W U) ¢ c Q <br />6 <br />Z- NJa0 <br />� �., z o <br />3N a 6 NJ <br />tL <br />Z U <br />W ❑0O <br />U M <br />z � S <br />Q <br />o' <br />N <br />Up) z U_ <br />C1 <br />1/ <br />0 <br />W <br />� a <br />'1't• <br />U <br />0 w s <br />to c <br />�in <br />(13 CO <br />LU <br />E <br />t 8 <br />1 <br />U � <br />co <br />e <br />� <br />c cosrQ <br />o <br />co <br />W <br />M <br />zZ <br />o <br />Z <br />ce o <br />U <br />tW <br />1. <br />XU <br />w¢ <br />0OU <br />no <br />z� <br />N E <br />a��¢ <br />¢ $ <br />wZ <br />ro <br />mg <br />O <br />z <br />J <br />< ° <br />g2 <br />N <br />47 <br />p g <br />LL <br />.OU <br />a <br />�W <br />W <br />J <br />o <br />Z <br />w� <br />�5 <br />�° <br />CO <br />�T <br />za <br />a <br />Ova <br />=CN <br />12 C] <br />> Lo <br />0 <br />c <br />& <br />B <br />O <br />O <br />IL.O <br />LO <br />T <br />W <br />O <br />0") <br />CO T <br />Q <br />OO <br />/ ) O <br />V ap <br />1— <br />CEO <br />N <br />04 <br />0 <br />I <br />Q t <br />L0 <br />C� M <br />r <br />ui <br />✓' C� <br />o <br />m:3 <br />z <br />E m <br />is <br />ca <br />E v a3 <br />c <br />a.0 <br />¢ O <br />_J <br />JOB NO : 22-01577-01572 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN1 <br />PASCO COUNTY <br />
The URL can be used to link to this page
Your browser does not support the video tag.