Laserfiche WebLink
'll ,�-1"'t ail®ral,e ee. 7llf"" , ,1tl .'." i " rt a r..'_, .. IfPr�lAlq� 4�Rl ISIh ��1'�! - 111 lewIFIT 11e � ,I 11 Tjll'1I}I'W _ - - 114 "111111 1 IT <br />I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />01 #14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />15a AMP/ <br />200 AMP 10 #10 to WH <br />10 #8 to Range <br />10 x8 to HVAC <br />METER <br />MAINT <br />50=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />INTERSYSTEM4 <br />Tnecl, <br />Bare Cu Ground <br />BONDING <br />GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />jCLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FEPc <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />4�3 <br />THREE-WAY SWITCH <br />�'4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />,O\ <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�10 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />A] <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�_Z/� <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK-UP. ALL SMOKE DETECTORS TO BE <br />ARC -FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />is <br />TO S <br />SEN <br />W <br />W.C. <br />2" VTR <br />2" VTR <br />W.C. <br />PLUMBING RISER <br />N.T.S. <br />NOTE: <br />Licensed Plumber to verify and has the authority <br />to change as needed to comply with the current code. <br />C. <br />MITARY <br />'ER <br />UNIT 1397 - ELECTRICAL PLAN <br />SCALE: 3/4"= V-0" <br />r <br />C)O <br />i� <br />O <br />0 co <br />N <br />Q CO ;,G <br />U_ rj_ <br />r -0 © 1.- <br />M C <br />W <br />�oo <br />U <br />oW <br />CV <br />CV <br />O <br />CV <br />0 <br />M <br />O <br />t <br />•'°'( �': LEA✓,`f �!:s <br />�•,��CENS ° <br />,`,� <br />No F�7875A' - <br />A <br />5-' STD. T = Cr= ' 4./ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />C) <br />H o � coFZ* <br />$ m <br />d <br />N O 0. <br />a y' M V Y <br />rp U. LL. tL <br />Z mc°a 0 <br />= o � 0 1_ <br />W Z FeL <br />03 m O J <br />W 0 <br />W ' <br />do ZO <br />a <br />"Z Lr)N cV,1 Z a• rn 0 <br />= pV c�_jvVi <br />W <br />c <br />Z N �f�y' <br />Z O Q <br />Q <br />J <br />a <br />r` <br />z <br />(D <br />y Q <br />�N <br />W C <br />U <br />O—� <br />W 8 <br />�N = U) <br />U a; <br />�— E <br />as <br />c U) <br />• <br />Ia <br />a <br />S0 <br />oco <br />w <br />M <br />2 <br />V5s <br />z <br />g <br />1UUo�° <br />a <br />❑z❑nm>a <br />00 <br />Do <br />OnFz <br />t <br />¢ <br />oZ <br />W Z <br />z <br />ozC o7ZZ <br />O� <br />o <br />z®� <br />WONEz <br />U <br />< <br />� <br />r <br />j <br />y <br />W <br />CDtt <br />CD <br />co <br />�V <br />W F <br />O <br />r <br />0l� ij <br />z <br />3 <br />c <br />0 <br />Ln <br />(o <br />— <br />ai <br />� <br />O <br />O <br />r <br />� <br />O <br />Co r <br />Q <br />_M <br />60 <br />� o <br />In <br />r <br />Q <br />T <br />CEO <br />N <br />= <br />o N <br />Q C:)L!) <br />C6 <br />0 <br />O T <br />� <br />illCD <br />M <br />o <br />m <br />z <br />T <br />E <br />Z <br />m <br />c <br />a. <br />0 _j Q p <br />= <br />JOB <br />NO: 22-01577-01572 <br />SCALE : AS NOTED <br />SHEET NO. <br />7 <br />