NOTE: METERS M, <br />RELOCATED <br />N❑TESi <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE, 12' AFF (GENERAL) <br />KITCHEN 44' AFF <br />BATHROOM 39' AFF <br />LAUNDRY ROOM 36' AFF <br />EXTERIOR WATERPROOF 12' AFF <br />GARAGE GENERAL PURPOSE 42' AFF <br />RANGE 2' AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE P❑SSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF. <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY, ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF ALL ELECTRICAL, WIRING & ACCESS❑RIES. <br />5. ALL SMOKE DETECTORS SHALL BE HARDWIRED INT❑ AN ELECTRICAL POWER SOURCE <br />AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY BACKUP, <br />INSTALL SMOKE DETECTOR/CARBON MON❑XIDE ALARMS PER FBC R313. <br />6. ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAULT OR GROUND FAULT <br />PROTECTED PER NEC 2008 210.12 (B) <br />7. ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER NEC 2008 406.11 <br />8, GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. 2008 <br />9. R313.2 1 CARBON MONOXIDE PROTECTION, CARBON MON❑XIDE ALAMRS OR DETECTORS <br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70. SUC <br />DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, <br />STANDARD FOR SINGLE AND MULTIPLE STATI❑N CO ALARMS OR UL 2075, GAS <br />AND VAPR❑ DETECTOR SENSOR, ACC❑RDING TO THE INSTALLATION. <br />10 . 313.2.2 3 COMBINATI❑N ALARMSt COMBINATION SMOKE/CARBON M❑N❑XIDE ALARMS <br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATI❑N UL STANDARD. <br />11. KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS. <br />12. IN NEW C❑NSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INT❑ THE A/C <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY <br />BACKUP. <br />13, BATHROOM EXHAUST FANS MUST VENT TO THE EXTERI❑R OF THE BUILDING, <br />VENTILATI❑N TO ATTIC SPACE AND S❑FFITS IS NOT ACCEPTABLE. <br />14. ALL DOORS AND WIND❑WS PROVIDING DIRECT ACCESS FROM THE HOME TO THE <br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM COMPLYING WITH UL 2017 THAT <br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER <br />HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A <br />CONTINUOUS AUDIBLE WARNING WHEN THE DOOR OR WIND❑W ARE OPENED, <br />15. ADD GFCI PROTECTI❑N TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS <br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE OUTSIDE EDGE OF A SINK. <br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE. <br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A <br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24'. <br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL <br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12' <br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN <br />CORNER COUNTERS. <br />$ SWITCH <br />$3 3 WAY SWITCH <br />$4 4 WAY SWITCH <br />$R RHEOSTAT SWITCH <br />8 110 V RECEPTICLE(1/2 SWITCHED) <br />8 110 V RECEPTICLE <br />WFI 110 V RECEPTICLE - GROUND FAULT <br />8AFI 110 V RECEPTICLE - ARC FAULT <br />Bra 110 V RECEPTICLE - WATERPROOF OUTLET <br />6 220 V RECEPTICLE <br />A DUPLEX OUTLET IN FLOOR <br />16 110 V QUAD <br />16vP 110 V QUAD WATERPROOF OUTLET <br />® RECESSED INCANDESCENT <br />' ? LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 5❑ CFM'S <br />EXHAUST FAN/LIGHT COMBINATI❑N <br />® FL❑URESCENT FIXTURE <br />dD FLOOD LAMPS <br />VANTITY LIGHT <br />GD PUSH BUTTON FOR GARAGE OPENER <br />SOD SMOKE /FIRE DETECTOR/ALARM <br />c(sm SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO <br />© CARBON MON❑XIDE DETECTOR <br />FAN <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />ELECTRICAL PLAN <br />