Laserfiche WebLink
F_ <br />I <br />L <br />3— 2/0 THNN CU FEEDERS <br />GALV RISER <br />ZOR2' CHASE W/(3) #210 THW COP. <br />(3) #410 THW AL. <br />200 AMP MAIN BREAKER <br />2�o AMP PANCIRCUIT <br />L ON INSIDE SURFACE <br />WALL <br />METER SOCKET <br />00 <br />i i <br />2' GALV NIPPLE <br />I' <br />UNDERGROUND SERVICE II <br />(IF AVAILABLE) #4 CU DRIVEN GROUND <br />RODS 2 EACH 8'-0' APART MIN, <br />3/8' X 8' GROUND ROD <br />CONCRETE ENCASED 'UFER' ELECTTODE REQUIRED PER ART 250-50 <br />N.E,C. MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT, <br />NOTEi ELECTRICAL MATERIAL AND INSTALLATIONS SHALL C@iPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 — 12, LOCAL CODES AND THE LOCAL POWER CO. <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />NOTE: METERS MAY BE LOCATED <br />WITH DUKE ENERGY <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1, ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE, 12' AFF (GENERAL) <br />KITCHEN 44' AFF <br />BATHROOM 39' AFF <br />LAUNDRY ROOM 36' AFF <br />EXTERIOR WATERPROOF 12' AFF <br />GARAGE GENERAL PURPOSE 42' AFF <br />RANGE 2' AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />3. ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF, <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ❑ <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR WHO <br />FOR THE INSTALLATION & SIZING OF ALL ELECTRICA <br />5. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO A <br />AND SHALL BE EQUIPPED WITH A MONIT❑RED BATTERY <br />INSTALL SMOKE DETECTOR/CARBON MONOXIDE ALARMS <br />6. ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAU <br />PROTECTED PER NEC 2017 210.12 (B) <br />7. ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER <br />POSSIBLE <br />L <br />NLY, ALL WORK SHALL <br />ELECTRIC CODE, LATEST <br />SHALL BE RESPONSIBLE <br />, WIRING & ACCESSORIES. <br />N ELECTRICAL POWER SOURCE <br />BACKUP, <br />PER FBC R313. <br />LT ❑R GROUND FAULT <br />NEC 2017 406.11 <br />8. GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C, 2017 <br />9. R313.2 1 CARBON MONOXIDE PROTECTION, CARBON MONOXIDE ALAMRS OR DETECTORS <br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70. SUCF <br />DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, <br />STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS <br />AND VAPRO DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. <br />10 , 313.2.2 3 COMBINATION ALARMSi COMBINATION SMOKE/CARBON MONOXIDE ALARMS <br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATION UL STANDARD. <br />11, KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS. <br />12, IN NEW CONSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INTO THE A/C <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONIT❑RED BATTERY <br />BACKUP. <br />13. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERIOR OF THE BUILDING, <br />VENTILATION TO ATTIC SPACE AND SOFFITS IS NOT ACCEPTABLE. <br />14, ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE <br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM COMPLYING WITH UL 2017 THAT <br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER <br />HARDWIRED OR OF THE PLUG—IN TYPE. THE EXIT ALARM SHALL PRODUCE A <br />C❑NTINU❑US AUDIBLE WARNING WHEN THE DOOR OR WINDOW ARE OPENED. <br />15. ADD GFCI PROTECTION TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS <br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE OUTSIDE EDGE OF A SINK, <br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE. <br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A <br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 241. <br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL <br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12' <br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN <br />CORNER COUNTERS. <br />SYMBOL <br />DESCRIPTION <br />SWITCH <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />RHEOSTAT SWITCH <br />8 <br />110 V RECEPTICLE(1/2 SWITCHED) <br />8 <br />110 V RECEPTICLE <br />&FI <br />110 V RECEPTICLE - GROUND FAULT <br />VAFI <br />110 V RECEPTICLE - ARC FAULT <br />WP <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />6 <br />220 V RECEPTICLE <br />A <br />DUPLEX OUTLET IN FLOOR <br />6 <br />110 V QUAD <br />gWP <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />FL❑URESCENT FIXTURE <br />dD <br />FLOOD LAMPS <br />VANTITY LIGHT <br />GD <br />PUSH BUTTON FOR GARAGE OPENER <br />SOD <br />SMOKE /FIRE DETECTOR/ALARM <br />cOn <br />SMOKE/CARBON MONOXIDE DETECTOR — COMBO <br />© <br />CARBON MONOXIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN W/L <br />DISCONNECT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />Al- <br />ELECir-n-RICAL <br />