6789-6799 Bassword Cir
Zephyrhills
>
Building Department
>
Building Plans
>
6789-6799 Bassword Cir
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:45:42 AM
Creation date
2/19/2025 8:56:50 AM
Metadata
Fields
Template:
Building Plans
Street #
6789-6799
Location
Basswood Cir
Contractor
Ryman Construction
Building Plans - Permit #
242-246
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2/0 THNN CU FEEDERS <br />GALV RISER <br />2' CHASE <br />V0/T0) #eI0 THV COP. AL <br />OR <br />40°cIRcuiT AMP MAIN BREACE�iT <br />PANEL W INSIDE nc,E VALL <br />vo <br />II 2' GALV NIPPLE <br />I <br />UNDERGROUND SERVICE I I <br />(IF AVAU ABLE> — � ! •4 CU DRIVEN GROUND <br />y I RODS 2 EACH B'-V APART MIN. <br />3/8' X B' GROUND ROD <br />CONCRETE ENCASED 'LIFER' ELECTTODE REQUIRED PER ART 250-50 <br />N.E.C. MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT. <br />NOTE. ELECTRICAL MATERIAL AND INSTALLATIONS SWILL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 12, LOCAL CODES AND THE LOCAL POWER CO. <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />NOTE: METERS MAY BE LOCATED <br />WITH DUKE ENERGY <br />R, <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE= 12' AFF (GENERAL) <br />KITCHEN 44' AFF <br />BATHROOM 39' AFF <br />LAUNDRY ROOM 36' AFF <br />EXTERIOR WATERPROOF 12' AFF <br />GARAGE GENERAL PURPOSE 42' AFF <br />RANGE 2' AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF. <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE <br />FOR THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & ACCESSORIES. <br />5. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE <br />AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. <br />INSTALL SMOKE DETECTOR/CARBON MONOXIDE ALARMS PER FBC R313. <br />6. ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAULT OR GROUND FAULT <br />PROTECTED PER NEC 2017 210.12 (B) <br />7. ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER NEC 2017 406.11 <br />8. GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. 2017 <br />9. R313.2 1 CARBON MONOXIDE PROTECTION, CARBON MONOXIDE ALAMRS OR DETECTORS <br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70. SUCK <br />DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, <br />STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS <br />AND VAPRO DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. <br />10 . 313.2.2 3 COMBINATION ALARMSi COMBINATION SMOKE/CARBON MONOXIDE ALARMS <br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATION UL STANDARD. <br />11. KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS. <br />12. IN NEW CONSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INTO THE A/C <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY <br />BACKUP. <br />13. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERIOR OF THE BUILDING, <br />VENTILATION TO ATTIC SPACE AND SOFFITS IS NOT ACCEPTABLE. <br />14. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME To THE <br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM COMPLYING WITH UL 2017 THAT <br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER <br />HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A <br />CONTINUOUS AUDIBLE WARNING WHEN THE DOOR OR WINDOW ARE OPENED. <br />15. ADD GFCI PROTECTION TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS <br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE OUTSIDE EDGE OF A SINK. <br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE. <br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A <br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24'. <br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL <br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12' <br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN <br />CORNER COUNTERS. <br />SYMBOL <br />DESCRIPTION <br />$ <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />ii <br />110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />WFI <br />110 V RECEPTICLE - GROUND FAULT <br />8wi <br />110 V RECEPTICLE - ARC FAULT <br />8WP <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />8 <br />220 V RECEPTICLE <br />I] <br />DUPLEX OUTLET IN FLOOR <br />36 <br />110 V QUAD <br />][WP <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />'? <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />FLOURESCENT FIXTURE <br />4D <br />FLOOD LAMPS <br />VANTITY LIGHT <br />GO <br />PUSH BUTTON FOR GARAGE OPENER <br />SGR <br />SMOKE /FIRE DETECTOR/ALARM <br />o� <br />SMOKE/CARBON MONOXIDE DETECTOR - COMBO <br />© <br />CARBON MONOXIDE DETECTOR <br />�r <br />rN <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />C, <br />FAN W <br />Q' <br />DISCONNECT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />ELECTRICAL PLAN <br />