Laserfiche WebLink
v <br />v <br />0 <br />r- <br />t2 <br />0 <br />.9 <br />7t <br />C1 <br />0 <br />0 <br />cn <br />a <br />0 <br />t2 <br />0 <br />J <br />sc <br />0 <br />0 <br />�i <br />rn <br />CD <br />i <br />E <br />9 <br />c <br />a� <br />t� <br />0 <br />U <br />rJ <br />i <br />U <br />i <br />z <br />I <br />Y <br />i <br />V <br />s <br />N <br />:3 <br />0 <br />a <br />LO <br />rn <br />L <br />Ci <br />CIA <br />I WALL LEGEND I <br />8'-8" TOP OF MASONRY WALL <br />(GARAGE) <br />9'-4" TOP OF MASONRY WALL <br />I 18'-8" TOP OF MASONRY WALL <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-9'-4" TOP OF MASONRY WALL <br />(LANAI) , W/ SHAFT LINER ABOVE TO <br />BOTTOM SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-18'-8" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />77 -2HOUR FIRE RATED SEPARATION <br />WALL <br />-20'-0" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />TYP. INTERIOR WALL <br />BEARING WALL <br />I <br />I <br />I <br />L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ <br />(1787) <br />(1666) <br />SYMMETRICAL <br />SYMMETRICAL <br />I <br />I <br />I <br />— — — — — — — — — — — — — — — — — — — — — — — — -- <br />2nd FLR ELECTRICAL PLAN <br />SCALE: &=V-0" <br />Riser Diagram <br />6 UNIT BUILDING <br />2/0 CU GEC <br />CONNECTED <br />TO LIFER AND <br />(2) RODS <br />450 AMP <br />SERVICE <br />00 <br />150 AMP <br />0 <br />150 AMP <br />150 AMP <br />(2) 3" SCH 80 PVC CONDUITS <br />WITH (2) 500 MCM XHHW AL <br />AND (1) 350 MCM XHHW AL <br />EACH CONDUIT <br />(3) METERS PER BANK <br />(2) METER BANKS PER <br />6-UNIT BLDG. <br />(ONE ON EA. SIDE) <br />(1) 1 k SCH 80 PVC CONDUIT <br />WITH (2) 2/0 XHHW AL <br />(1)#1 XHHW AL <br />(1) #4 XHHW AL <br />TYPICAL ALL UNITS <br />NOTE: <br />• ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH <br />APPLICABLE PROVISIONS OF THE NFPA 70 -17, LOCAL CODES AND <br />THE LOCAL POWER CO. <br />• INSTALL 2" CONDUIT TO METER CAN <br />• INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13, Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />JR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />iO <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />own <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�-67 <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />N <br />Nic <br />ti O <br />ty <br />-� U co <br />co X <br />(in iz) m <br />-.ANY <br />.N Q) C Q <br />- Ly Q) 0 0 <br />tt E c: <br />M N 0 O <br />:3V = <br />t: <br />>>� 0W <br />N <br />N <br />0 <br />N <br />era <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the <br />2020 Florida Building Cade - <br />Residential <br />7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and <br />seal. <br />a <br />a <br />11- <br />LQC <br />�� <br />0)N r rZ 32 8 J <br />Q �LLtL LL a <br />13 <br />D 0) (L <br />gm_ 0 <br />W <br />� � °' m <br />LW <br />w <br />Z ,°�° " Z d M <br />;w N <br />O U 0 <br />Z CD <br />W 013 <br />`c <br />Z cn <br />I <br />i3 <br />a <br />N <br />N z v <br />CO ii <br />a--+ N <br />W <br />" A <br />V <br />8 <br />0 <br />c <br />N U.. <br />in <br />(� r— <br />W W <br />t <br />W <br />Z <br />J <br />- E <br />o <br />� <br />zo <br />-0 <br />< <br />Z <br />z� <br />O <br />_® <br />cc <br />ea <br />00 <br />o <br />- rp <br />c <br />o <br />o� <br />- N <br />`_0 <br />aw <br />Iz <br />az <br />SSC <br />a� <br />sir <br />nw <br />�r <br />p <br />a, <br />5. <br />a x <br />VCD' <br />3 <br />__ <br />in <br />LL <br />O <br />'M <br />0 <br />2 <br />F_ <br />J <br />LL <br />O <br />L <br />co <br />� <br />M <br />0000 <br />Q <br />r <br />T_Cr <br />O <br />CV <br />04 <br />fO <br />O <br />O <br />04 <br />°' <br />1117 <br />T <br />T. <br />E <br />3 <br />Z <br />Z <br />E <br />�C) V1 <br />V <br />a <br />0 <br />v? <br />-°r Q O <br />c <br />JOB <br />NO: <br />22-05614-05611 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />15 <br />