Laserfiche WebLink
! II 1 I __ i _ I I _ <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1 -1/0 COPPER <br />0 <br />OR <br />2-4/0 ALUMINUM <br />150 AMP 42 <br />METER <br />1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. 11 <br />BAKER <br />PVC—�- <br />Pvc­__r"'_ <br />1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />0 <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />n <br />ELECTRICAL <br />METER (V.I.F.) <br />A/C <br />DISCONNECT <br />h/ GFWP <br />- ----------------------------- - - - - --- ___ ) <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />' THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />oll VAPOR PROOF LIGHT FIXTURE <br />+Pc LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />C� EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />© CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />Q SMOKE DETECTOR <br />F4 TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />p] ELECTRIC METER <br />= ELECTRIC PANEL <br />_jm.L DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I--- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITI <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUN <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPI <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE <br />W <br />Lu <br />�OOF- <br />>m<0 <br />W Z) C) I- <br />� w <br />Q 0 W F- <br />— <br />J U) W LLI <br />Z) (r <br />Y O I- Z <br />oLL ow <br />Z 4Z Z ~ Z_ <br />crJ Q --� <br />w CL <br />Z = Z LL U) <br />H Q Z <br />n <br />a <br />H <br />0 <br />� Q <br />Q <br />O <br />O <br />O <br />U <br />O <br />Z <br />00 <br />a <br />O <br />O <br />�} <br />CL <br />cn <br />w <br />j <br />w <br />w <br />x <br />IL <br />Z <br />O <br />E <br />R <br />U) <br />W <br />to <br />�_� <br />