Laserfiche WebLink
36049 Shady Bluff Loop <br />Plan Review Comments — Single Family Residences <br />1. F.F.E. shall be a minimum 8" above road elevation or to the engineered site <br />plan. <br />2. Tie-in survey required before pre -slab inspection to show elevation. <br />3. Compaction test required if 24" of fill is brought in at any one place. <br />4. All setbacks shall be met. <br />5. All property markers to be exposed before first inspection. <br />6. All appliances shall be protected from car impact in garage. <br />7. Return air in all bedrooms. F.B.C. M1620.4 <br />8. Ground mounted A/C units shall be anchored per F.B.C. M1307.3.1 <br />9. Lot shall be graded as to comply with 401.3 of the F.B.C. <br />10. Drainage Plan Requirements must be made: Ordinance #974-07 Section 6. <br />11. Smoke alarms to be installed per code 313.1 of the F.B.C. <br />12. All glazing requirements to be met per code 308.4 of the F.B.C. <br />13. All means of egress are to be per code 311 of the F.B.C. <br />14. R.O.W. use permit required for all driveways and all driveways to include <br />expansion materials. <br />15. All water heaters shall have a thermal expansion control device installed per <br />F.B.0 plumbing 607.3 <br />16. Combination -type AFCI breaker are required at all locations requiring an AFCI. <br />F.F.E. — Finished Floor Elevation <br />F.B.C. — Florida Building Code <br />R.O.W. - Right Of Way <br />