SVR Lot 4 Block 2 <br />I. GENERAL: <br />1.1 SPECIFICATIONS <br />= FRC 2004 <br />1.2 DESIGN LOADS: <br />TCLL = <br />20 PSF <br />TCDL = <br />10 PSF <br />BCLL = <br />10 PSF <br />BCDL = <br />10 PSF <br />1.3 ANCHORAGES SHALL BE HOT -DIPPED GALVANIZED, AFTER FABRICATION <br />PER ASTM A 90. <br />1.4 WINDOWS, EXTERIOR DOORS, GARAGE DOORS AND OTHER <br />VENDOR -PROVIDED EXTERIOR CLADDING SHALL COMPLY WITH THE FRC 2004 <br />INCLUDING THE DESIGN CRITERIA SET FORTH IN THE FOLLOWING WIND LOAD <br />NOTES. <br />1.5 EXTERIOR WINDOWS & GLASS DOORS ARE REQUIRED TO BE TESTED IN <br />ACCORDANCE WITH ANSI/AMMA/NWWDA 101/IS2 STANDARD & BEAR AN AMMA <br />OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE <br />CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />1.6 EXTERIOR WINDOWS & DOORS SHALL BE ANCHORED PER PUBLISHED <br />MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE <br />SPECIFIED. <br />1.7 GARAGE DOOR SHALL BE FASTENED w/ MANUFACTURER'S TRACK <br />BRACKETS USING 1/4"xl-1/2" HEX -HEAD LAG BOLTS FULLY SEATED IN PT <br />26, #2 SYP (MIN) DOOR BUCKS. FASTEN BUCK STRIPS TO MASONRY WALL <br />w/ 1/2"0 ANCHOR BOLTS w/ 2"0 WASHERS @ 18" O.0 (5 MIN. PER SIDE). <br />ANCHOR BOLTS SHALL BE CAST IN PLACE <br />1.8 MULLONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE <br />TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGNED LOADS TO <br />THE ROUGH OPENING SUBSTRATE. <br />II. WOOD FRAMING: <br />4.1 TRUSSES SHALL BE DESIGNED PER FRC 2004 AND TPI SPECIFICATIONS <br />AND CERTIFIED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF <br />FLORIDA. BRACING SPECIFIED BY THE TRUSS MANUFACTURER (INTERNAL TO <br />THE TRUSS SYSTEM) WITHOUT FASTENING INSTRUCTIONS SHALL BE FASTENED <br />WITH 2-16d NAILS PER BEARING POINT AT CROSS BRACING, AND 10d NAILS - <br />8" O.C. ALONG STIFFENERS (I.E.: 'L' AND 'T' BRACING) AND 3-16d NAILS <br />TOE -NAILED AT END BEARING CONNECTIONS. <br />4.2 TRUSSES SHALL BE BRACED IN ACCORDANCE WITH THE TRUSS PLATE <br />INSTITUTE'S (TPI) BSCI 1-03. <br />4.3 ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE (SYP) <br />MINIMUM U.O.N. <br />4.4 ALL LOAD BEARING FRAME WALLS SHALL BE STUD GRADE SP (MIN), <br />STUD SPACING AT 16" O.C. WITH DOUBLE TOP PLATE. TOP PLATE JOINTS <br />SHALL BE LAP -SPLICED A MINIMUM OF 48" AND FASTENED WITH 15-16d <br />NAILS. <br />4.5 ALL NON -LOAD BEARING FRAME WALLS SHALL BE STUD GRADE SPF <br />(MIN), STUD SPACING AT 16" O.C. <br />III. MASONRY: <br />3.1 MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 530 <br />(CURRENT). <br />3.2 MORTAR FOR ALL MASONRY WALLS SHALL CONFORM TO ASTM C 270, <br />TYPE M OR S. <br />3.3 ALL CONCRETE BLOCKS SHALL BE STANDARD WEIGHT BLOCKS <br />CONFORMING TO ASTM C-90 (fm=1,350 PSI (MIN.)). <br />3.4 GROUT SHALL CONFORM TO ASTM C 476. <br />3.5 USE FINE GROUT FOR COLLAR JOINTS 1" WIDE OR LESS AND WHEN <br />GROUTING CELLS OF HOLLOW MASONRY UNITS, WITH OR WITHOUT VERTICAL <br />REINFORCING. USE 3000 psi FINE GROUT (3/8" AGGREGATE MAX.) WHEN <br />GROUTING BOND BEAMS & PRECAST UNITS. <br />3.6 CONVENTIONAL REINFORCING BARS (VERTICAL & HORIZONTAL) SHALL <br />CONFORM TO ASTM A 615 GRADE 40 (MIN.), DEFORMED. <br />3.7 PROVIDE CLEAN -OUT OPENINGS FOR EACH GROUTED CELL. <br />3.8 ALL UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON FACE <br />SHELLS. <br />IV. FOUNDATIONS: <br />V. WIND LOAD NOTES: <br />5.1 DESIGNED PER FRC 2004 (2004 W/ 05 & 06 SUP) & ASCE 7-02 <br />5.2 BASIC WIND SPEED = 120 MPH (3 SEC. GUST) <br />5.3 WIND IMPORTANCE FACTOR = 1.0 <br />5.4 BUILDING CATEGORY = II <br />5.5 WIND EXPOSURE CATEGORY = C <br />5.6 INTERNAL PRESSURE COEFFICIENTS (GCpi) = 0.18 <br />5.7 EXPOSURE CATEGORY = ENCLOSED <br />5.8 ROOF DEAD LOAD: <br />(USED TO CALCULATE UPLIFT RESISTANCE) = 11.8 PSF <br />5.9 ROOFING SYSTEM = FIBERGLASS COMPOSITE SHINGLES <br />5.10 COMPONENTS & CLADDING (GCp) (ROOF): <br />ROOF ZONE 1, NEGATIVE _ -1.00 <br />ROOF ZONE 2, POSITIVE = 0.30 <br />5.11 ROOF MATERIAL WIND RESISTANCE RATING = FASTEN SHINGLES IN ACCORDANCE WITH FRC <br />2004 AND WITH ASTM D 3161 <br />5.12 COMPONENTS & CLADDING (GCp) (WALLS): SEE ELEVATION SHEETS <br />5.13 MAX. NET UPLIFT PER TRUSS BEARING CONNECTION = SEE TRUSS LAYOUT. <br />5.14 MAX. NET UPLIFT PER GIRDER BEARING CONNECTION = SEE TRUSS LAYOUT. <br />5.15 FACTOR OF SAFETY AGAINST OVERTURNING = 1.5 <br />2.1 CONTRACTOR SHALL ENSURE THAT CONCRETE CONFORMS TO ACI 301 5.16 EXTERIOR SHEATHING: FASTEN 15/32" WINDSTORM SHEATHING TO FRAMING WITH 8d NAILS <br />(CURRENT), SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI OR 0.131" P-NAILS AT 6" O.C. ALONG THE TOP AND BOTTOM PLATES, 6" O.C. ALONG PANEL <br />302 (CURRENT), GUIDE FOR CONCRETE FLOOR & SLAB CONSTRUCTION, AND EDGES, 12" O.C. ALONG INTERMEDIATE SUPPORTS. ALL EXTERIOR SHALL EXTEND FROM THE <br />ACI 318 (CURRENT), BUILDING CODE REQUIREMENTS FOR REINFORCED BOTTOM PLATE TO THE TOP MEMBER OF THE TOP PLATE. <br />CONCRETE. <br />2.2 CONCRETE SUPPLIER SHALL PROVIDE A MIX RESULTING IN A MINIMUM <br />COMPRESSIVE STRENGTH AT 28 DAYS, f'c=2,500 PSI AS MEASURED BY <br />TESTING CYLINDRICAL SPECIMENS PER ASTM C-39. <br />2.3 SUB -GRADE SHALL BE FREE OF ALL VEGETATION AND ORGANIC <br />MATERIALS. <br />5.17 WOOD -FRAME SHEARWALLS: FASTEN 15/32" WINDSTORM <br />SHEATHING TO FRAMING WITH 8d NAILS OR 0.131" P-NAILS AT 3" O.C. ALONG THE TOP AND <br />BOTTOM PLATES, 3" O.C. ALONG PANEL EDGES, 12" O.C. ALONG INTERMEDIATE SUPPORTS. <br />PROVIDE 2x4 BLOCKING EDGEWISE ALONG HORIZONTAL PANEL JOINTS. SHEARWALL ENDS SHALL <br />BE DOUBLE STUDS FASTENED TO BOTTOM PLATE WITH ONE (1) SIMPSON LTT20 TENSION TIE <br />WITH A 1/2" EPDXY SET ANCHOR BOLT WITH A MANUFACTURER'S PULL-OUT CAPACITY OF 1,750 <br />POUNDS (MIN). FASTEN TENSION TIE TO DOUBLE STUDS WITH 10-16d NAILS. <br />2.4 MINIMUM FOOTING COVER SHALL BE 12" BELOW FINISHED GRADE. <br />5.18 ROOF SHEATHING: FASTEN 7/16" APA RATED SHEATHING PERPENDICULAR TO FRAMING <br />2.5 A LAYER OF 6 MIL. POLYETHYLENE SHEATHING SHALL BE PROVIDED AS A WITH 8d NAILS OR 0.131" P-NAILS AT 4" O.C. ALONG FASCIA, 4" O.C. ALONG PANEL EDGES <br />VAPOR BARRIER UNDER THE SLAB. AND 6" O.C. ALONG INTERMEDIATE SUPPORTS. <br />2.6 SUB -GRADE SHALL BE MOIST DURING CONCRETE PLACEMENT. 5.19 ROOF DIAPHRAGM: FASTEN 7/16" APA RATED SHEATHING PERPENDICULAR TO FRAMING <br />WITH 8d NAILS OR 0.131" P-NAILS AT 4" O.C. ALONG DIAPHRAGM BOUNDARY (FASCIA), 4" O.C. <br />2.8 CONTRACTOR SHALL ENSURE THAT CONCRETE COVER TO REBAR IN THE ALONG PANEL EDGES, 6" O.C. ALONG INTERMEDIATE SUPPORTS. PROVIDE 2 x 4 BLOCKING <br />SLAB IS IN ACCORDANCE WITH ACI 318 (CURRENT). EDGEWISE ALONG HORIZONTAL PANEL JOINTS. <br />a. CONCRETE CAST AGAINST EARTH = 3" COVER <br />2.9 SAW CUTTING SHALL BE IN ACCORDANCE WITH ACI 302 (CURRENT). SAW <br />CUTTING SHALL TAKE PLACE AS SOON AS THE CONCRETE SURFACE IS FIRM <br />ENOUGH NOT TO BE TORN OR DAMAGED BY THE CUTTING BLADE. <br />2.10 ASSUMED SOIL BEARING CAPACITY IS 2000 LBS PER SQ. FT <br />REVIEWED FOR COMPLIANCE WITH THE <br />WIND LOAD PROVISIONS OF THE 2004 <br />FLORIDA RESIDENTIAL CODE (FRC) & <br />FLORIDA BUILDING CODE (FBC) (w/ <br />05 & 06 SUPPLIMENT), AND ASCE 7-02 <br />ALL OTHER DESIGN ELEMENTS SH BE <br />THE RESPONSYMFIIWO6➢ EVA�iE <br />2004 5 3 r d AV_ E 342 <br />CERTiFICA E a' 1 17AT ION # 9; <br />L. JASON BERGER, P.E. J y fWAT�B <br />PE# 64003 L <br />07 <br />0 <br />o <br />W <br />W <br />O <br />J <br />Q <br />cr_ <br />7 <br />f <br />O <br />2 <br />I- <br />03 <br />0 <br />U <br />� <br />� <br />Z <br />3 <br />(j <br />•� <br />O <br />6=mmmmma <br />5 <br />a <br />mom <br />SHEET NO. <br />S-1 <br /># 64003 <br />