Laserfiche WebLink
/1" FILLER <br />,.--3" FILLER <br />3'-5" L 2'-3" 2'-6" 2'-0" 2'-0" 1 <br />1" FILLER 3 FILLER <br />KITCHEN A <br />VANITY <br />HEAD i LIGHTS <br />v <br />3" FILLER <br />-0" 2'-6" 4'-0" 2'-0" T-T- <br />0io <br />0 <br />irw — <br />CV N <br />0 <br />co 00 cn 4" B.S. -� <br /><- 1� _ REF <br />SPACE <br />VERIFY <br />o WITH <br />`o MANUF. <br />MIRROR <br />(V O I?c) i!� <br />4" B.S. o ao <br />r` <br />0 <br />r O <br />m <br />14 1/2" X 18"- <br />DRYER VENT <br />RECESS <br />c <br />n <br />2'-6" L 2'-6" 1'4" 2'-6" V-3" 2" FILLER <br />11 <br />2" <br />MASTER BATH <br />C <br />1 /4 = 1 -0 <br />SHELF <br />6-0" A.F.F. <br />o "HANSEN" <br />220V� N BOX <br />W.H. <br />D W <br />io <br />M L.T. <br />L V-6" 3'-0" 2'-7" 1'-3" 2'-0" <br />::E UTILITY LAYOUT <br />1 /4 = 1 -0 <br />18" H. <br />PLATFORM <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />HEAD <br />r <br />N <br />�r <br />2'-0" LL 2'-0" 3'-0" I�L 3 -3" " <br />'3 FILLER <br />B KITCHEN <br />1 /4 - 1 -011 <br />1" FILLER <br />LINEN <br />OPT <br />i ON-Q BOX <br />(16" X 28") <br />i <br />�, i ATTACH <br />i TO STUD <br />I <br />Co <br />d d _ SECURITY <br />�---- BOX <br />(14" X 14") <br />o—CLOSET­1�\ <br />r —WALL — <br />TYP. STUD <br />AT 24" O.C. <br />q).gP . 0 SEC. DTL. <br />-0 <br />I <br />PC-4 <br />(2) 25 SH. <br />M.O. 76"X63" <br />7'-8" PRECAST <br />HID. AT 6-8" <br />23 SH. <br />M.O. 38"X38-l" <br />4-6 PRECAST <br />HD. AT 6-8" <br />1ST FLOOR PLAN <br />1 /411= 1'-011 <br />c AUWAU <br />PC-4 <br />(2) 25 SH. - <br />M.0.76"X63" `* <br />T-8" PRECAST <br />HD. AT 6'-8" <br />EGRESS <br />PC-3 <br />25 SH. <br />M.0.38"X63" <br />4'-6" PRECAST <br />HID. AT 6'-8" <br />* EGRESS <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING <br />SIZES WITH THE MANUFACTURER'S SPECIFICATIONS. <br />INSTALL RND DRYWALL BEADS AT HORIZ & VERT <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS <br />NOTED. <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE <br />SMOOTH FINISH. <br />LOCATE ALL PLUMBING STACKS BEYOND THE FRONT <br />ELEV ROOF RIDGES, IF ALLOWABLE PER CODE. <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) <br />APPLIED TO THE GARAGE SIDE. <br />ALL LOAD BRG. HEADERS TO BE (2) 2 X 12 (U.N.O.) W/ (2) <br />2 X 4 CRIPPLE STUDS AT EACH END. CONNECT PER <br />DETAILS 1 /S4 AND 4/S4. <br />ALL GIRDERS TO BE CONTINUOUSLY SUPPORTED BY (3) <br />2 X 4 B.U.C. (U.N.O.) AND CONNECTED AT BASE W/ (3) <br />CS16 OR (1) HTT16. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 3/4" FURRING AND GYP. <br />BOARD INTERIOR SIDE <br />8" CMU <br />NON -BEARING 2X4 STUD W/ 1/2" GYP. <br />UNO <br />NON -BEARING 2X4 STUD W/ 1/2" <br />GYP. UNO AND INSULATION <br />❑ = FILLED CELL W/(1) #5 VERTICAL <br />p = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />TOTAL LIVING SQ. FT. <br />= 1445 <br />SQ. FT. <br />GARAGE <br />= 478 <br />SQ. FT. <br />ENTRY <br />= 54 <br />SQ. FT. <br />TOTAL NON -LIVING SQ FT <br />= 532 <br />SQ. FT. <br />TOTAL SQ FT <br />= 1977 <br />SQ. FT. <br />CONC. PAD AT ENTRY <br />= 5 <br />SQ. FT. <br />PATIO <br />= 144 <br />SQ. FT. <br />TOTAL NOT UNDER ROOF <br />- 149 <br />SQ. FT. <br />NOTES: <br />- NOT ALL REQUIRED FLASHING IS INDICATED ON <br />DRAWINGS. PROVIDE FLASHING PER FBC 1403 AND 1503. <br />- FLASHING SHALL BE INSTALLED AT (1) WALL AND ROOF <br />INTERSECTIONS (2) WHEREVER THERE IS A CHANGE IN <br />ROOF SLOPE OR DIRECTION, AND (3) AROUND ROOF <br />OPENINGS. WHERE FLASHING IS OF METAL, THE METAL <br />SHALL BE CORROSION RESISTANT WITH A THICKNESS OF <br />NOT LESS THAN 0.019 INCH (26 GAGE (0,551 MM) <br />GALVANIZED SHEET). <br />ALL MANUFACTURERED PRODUCTS SUCH AS ROOFING, <br />WINDOWS, DOORS, ETC. ARE SHOWN HEREIN FOR <br />ILLUSTRATION PURPOSES ONLY. THE INFORMATION SHOWN <br />IS THE RESPONSIBILITY OF THE MANUFACTURER. THE <br />MANUFACTURER IS RESPONSIBLE FOR THE VALIDITY OF <br />THE COMPONENTS PROVIDED. ATTACHMENT INFORMATION <br />GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN, <br />CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE <br />RESPONSIBLE FOR INSURING THAT THE APPROPRIATE <br />PRODUCT/COMPONENT IS USED AND THAT IT HAS BEEN <br />INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH <br />THAT IT WILL WITHSTAND THE COMPONENTS AND CLADDING <br />PRESSURES REQUIRED BY THE SEALED PLANS. ENGINEER <br />OF RECORD HAS NOT REVIEWED THIS INFORMATION FOR <br />APPLICABILITY OR AS A FORM OF PRODUCT APPROVAL OR <br />ENDORSEMENT. <br />PRE -CAST AND PRE -STRESSED CONCRETE COMPONENTS <br />SHALL BE USED AND INSTALLED PER MANUFACTURER'S <br />SPECIFICATIONS. PRE -CAST LINTELS HAVE BEEN REVIEWED <br />AND PLACED BASED ON DESIGN ALLOWABLE LOAD INFOR- <br />MATION PROVIDED BY CAST CRETE. THEREFORE, CAST <br />CRETE IS A DELEGATED ENGINEER FOR THIS PROJECT. <br />ENGINEER OF RECORD MUST APPROVE IN WRITING ANY <br />CHANGE IN LINTEL MANUFACTURER. ALL OTHER <br />STRUCTURAL PRE -CAST COMPONENT MANUFACTURERS <br />MUST SUBMIT DESIGN LOAD INFORMATION TO ENGINEER OF <br />RECORD FOR APPROVAL. ENGINEER OF RECORD <br />RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER SUCH <br />INFORMATION HAS BEEN PROVIDED FOR REVIEW. <br />CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE <br />RESPONSIBLE FOR INSURING INFORMATION REQUESTED <br />ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN <br />A TIMELY MANNER WHEN AVAILABLE. <br />TOWEL BAR - (T.B.) = 56" A.F.F. <br />TOWEL BAR ABV. TUB DECK = 36" ABV. TUB DECK <br />TOILET PAPER DISP. - (T.P.) = 20" A.F.F. <br />ROD AND SHELF (SGLY (R/S) = 60" A.F.F. <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. <br />CORNER SHELF = 56" A.F.F. <br />MEDICINE CABINET - M.C. = 75" TO TOP OF CABINET A.F.F. <br />ALL PLUMBIN <br />, ELECT N H UGH -IN <br />MUST BE CO <br />REQUESTING <br />LETE, CNS I P A BEFOR <br />HE FRAMING 4424 <br />(813) 960-5685 PHONE <br />(813) 482-9128 FAX <br />JEREMY COUCH, P.E. <br />PROFESSIONAL ENGINEER # 70658 <br />I HEREBY CER71FY THAT I HAVE <br />REVIENED 714E ATTACHED DESIGN. <br />AND FIND IT TO BE IN COMPLIANCE <br />W7H SEC71ON R301 OF 7HE 2010 <br />FLORIDA BUILDING CODE <br />�., RES 71AL <br />THE ENGINEER HAS NOT REVIENED <br />14E PRE-ENGINEERED TRUSS MANUF <br />1 AYOUT 70 DETERMINE ANY LOAD <br />NG CONDITIONS AND RESERVES <br />RIGHT 70 MAKE ANY CHANGES <br />'AF7FR TRUSS LOAD WFORMA71ON IS <br />SUPPLIED M 714E ENGNVEEI? <br />O <br />c: O <br />cu <br />U <br />O <br />m <br />L <br />0 <br />J <br />J <br />J <br />O <br />Z <br />Z <br />Q J <br />U � � U <br />i- 0 Z 0 O J <br />m��LL0vi <br />W Q d Q W W <br />U ~ � O ~ <br />Z <br />Q <br />mz mU�°- <br />❑ ❑ ❑ ❑ ❑ <br />U <br />Z <br />I <br />Q <br />w <br />Dw <br />0 <br />1I <br />L ♦ <br />!n <br />w <br />Ld <br />0 <br />0 <br />c� <br />� <br />R <br />v <br />a <br />z <br />r <br />J <br />J <br />#0 <br />QC) <br />z <br />" <br />Z <br />0. <br />Do <br />W <br />W <br />j <br />0ell <br />� z <br />IL <br />U <br />o0 <br />0 <br />Nm <br />m <br />2 <br />�— w <br />cD o_ <br />Z <br />� o <br />'z <br />Q <br />0 z <br />Z <br />0 <br />ISSUE DATE <br />AUGUST 01, 2008 <br />REVISION DATE <br />08122108 REV MEMO <br />03125113 REV MEMO <br />SHEET <br />'.-I I kd'. 6I 0 . „ 111 L aI, Ift➢fui.ialiu➢43^„ul 1111 <br />SEALED FOR STRUCTURE ONL Y <br />FLOOR PLAN <br />