am <br />FRONT ELEVATION C 1/4" = 9' <br />12 <br />�5 <br />n <br />Ll <br />REAR ELEVATION <br />0 0 <br />0 00 <br />nu 0 <br />C i 4 " - i-' <br />CONTINUOUS RIDGE VENT (TYP) <br />CONTINUOUS RIDGE VENT <br />REG. MOLD. <br />4.5X8.5" <br />0.94 <br />1.99 <br />3.77 00 <br />1.80 <br />1.00 1,41 <br />FOAM DETAIL <br />ROOF SHEATHING <br />PER GENERAL NOTES <br />ATTACH TO TOP CHORD <br />BACK NAIL W/ (2) <br />W/SIMPON H2.5 (OR <br />12d COMMONS <br />EQUAL) <br />2X4 LADDER/OUTLOOKER <br />"T" OR "L" <br />24" OVERHANG SPACE 24" <br />BRACING SCISSOR TRUSS <br />O.C. 12"/16" OVERHANG <br />(REQ'D) <br />SPACE 48" O.C. <br />NOT SHOWN <br />SIDING OR SHEATHING <br />(SEE GENERAL NOTES <br />FOR PANEL SIZE & <br />ATTACHMENT) <br />2x4 RAT RUNS OR 2x4 BLOCKING <br />48" O.C. FOR FIRST FOUR FRAMING <br />ATTACH 2X4 DIAPHRAM TOJ <br />SPACES FROM EACH END ATTACH <br />GABLE TRUSS VERTICAL <br />TO EACH BOTTOM CHORD MIN. (2) <br />WEBS W/(2) 10d <br />10d COMMON NAILS <br />COMMON NAILS <br />RYWALL NAILER <br />GABLE END TRUSS <br />KNEE WALL <br />12 <br />�5 <br />LEFT ELE VA TION C 114 99 e <br />12 <br />�5 <br />RIGHT ELE VA TION C 9 /4 " = I' <br />TRUSS BRACING PER \_STRAP TRUSS W/ SIMPSON <br />TRUSS MFG. SPECS HETA20 (OR EQUAL) USING <br />CONTINUOUS (6) 10d NAILS (MIN) ® 48" <br />BOND BEAM W/ O.C. <br />(1) #5 REBAR 9 <br />CATHEDRAL @ CABLE DETAIL <br />STRUCTURALLY CONTINUOUS WALL <br />NOT TO SCALE <br />2x4 RAT RUNS OR <br />2X4 BLOCKING 4'-0" <br />O.C. FOR FIRST FOUR <br />FRAMING SPACES <br />FROM EACH END <br />STRAP TRUSS W/ <br />SIMPSON HETA20 (OR <br />EQUAL) USING (6) <br />10d NAILS (MIN) @- <br />48" O.C. <br />i � a i <br />2-1 6d <br />5d COOLER NAILS OR <br />GWB54 ® 7" O.C. <br />MASONRY GENERAL NOTES <br />GENERAL NOTES <br />STRUCTURAL DESIGN CRITERIA <br />1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD BUILDING CODE <br />1. FBC FBCR 2010 <br />REQUIRMENTS FOR CONCRETE MASONRY STRUCTURES (ACI 530-08). <br />2. ASC /SEI 7-10 CODE (140 mph) <br />2. CONCRETE BLKS SHALL CONFORM TO ASTM C 90 (28 DAY STRENGTH=2000 <br />3. STRUCTURE RISK CATEGORY = II <br />PSI, FM=1350 PSI) LAID IN RUNNING BOND. <br />4. ENVELOPE PROCEDURE FOR LOW RISE BUILDINGS <br />3. MORTAR SHALL BE TYPE S OR M. <br />5. EXPOSURE FACTOR = B <br />4. WHERE SHOWN, CELLS OF MASONRY BLOCK SHALL BE FILLED WITH CONCRETE <br />6. INTERNAL PRESSURE COEFFICIENT = f0.18 <br />WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS & 1-#5, <br />7. 2nd FL LOADS: LIVE LOAD-40 PSF/DEAD LOAD-10 PSF <br />VERTICAL. <br />8. ROOF LOADS: LIVE LOAD-20 PSF/DEAD LOAD-10 PSF <br />5. PROVIDE KNOCK -OUT IN CONCRETE MASONRY UNIT AT BASE OF EACH FILLED <br />9. COMPONENT & CLADDING WALL PRESSURE= (+35.3) (-47.2) PSF (MAX) <br />CELL TO ALLOW VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. <br />ROOFING / FLASHING <br />DRAINAGE <br />ROOF DEAD LOAD - 7# P.S.F. ROOF LIVE LOAD - 20# P.S.F. ALL ROOF <br />PROVIDE AN ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE <br />FOUNDATION, WHICH WAS NEEDED IN SITUATIONS LIKE "ZERO -LOT -LINE" <br />COMPONENTS ARE PRE-ENGINEERED TRUSSES. ENG. WILL BE SUPPLIED TO <br />FIELD INSPECTOR AT TIME OF FRAMING INSPECTION (SEE TRUSS LAYOUT <br />CIRCUMSTANCES. THE ALTERNATIVE IS TO PROVIDE A MINIMUM OF 5% <br />PROVIDED. ROOF SHEATHING NAILING SCHEDULE FOR 7/16" OSB ROOF <br />) / <br />SLOPE AWAY FROM THE FOUNDATION. <br />, <br />DECK, USE 8d CC NAILS, SPACE 6" O.C. AT EDGES & 6' O.C. IN FIELDS. <br />STEMWALL FOOTING <br />GAF SENTINEL/TIMBERLINE/CERTAINTEED FIBERGLASS SHINGLES SECURE <br />STEMWALL FOOTING AS SHOWN ON WALL SECTION UP TO 36" HIGH CAN BE <br />w/(5) NAILS PER SHINGLE ON 15# FELT OVER 7/16" OSB ROOF DECK. <br />USED WITH UNBALANCED FILL. UNBALANCED FILL GREATER THAN 36" SHALL BE <br />PRODUCT MEETS ASTM D3462, D3161 F, D7158 G AND UL 997 FOR WIND <br />TEMPORARILY SUPPORTED DURING BACKFILLING & CONCRETE SLAB PLACEMENT <br />SPEEDS UP TO 140 MPH. FLASH ALL VALLEYS W/ MIN. 16"x26GA VALLEY <br />BY CONTRACTOR. THE MAXIMUM STEMWALL HEIGHT SHALL BE 10'-0" <br />METAL PLACED OVER FELT NAILED 12" o.c. ® EDGES. WHERE WALLS MEET <br />WINDOWS <br />ROOF LINE, ALL FLASHING SHALL CONFORM TO FBC REQUIREMENTS. <br />ALL WINDOWS TESTED AND APPROVED IN ACCORDANCE WITH ANSI/AMMA/NWWDA FRAMED WALLS <br />101/IS2 STANDARD AND LABELED AS SUCH. WINDOWS TO BE INSTALLED PER <br />ALL INTERIOR NON -BEARING WALLS MEET R6021.3.1. WALLS TO BE STD SPF <br />MANUFACTURERS REQUIREMENTS FOR APPLICABLE DESIGN PRESSURE. WINDOWS <br />OR HIGHER GRADE. <br />IN MASONRY WALLS SHALL BE ANCHORED THROUGH 1x BUCK INTO MASONRY. <br />ALL INTERIOR FRAMED BEARING WALLS TO BE #2 SPF. <br />WINDOWS IN WOOD FRAMED WALLS MAY BE INSTALLED WITHOUT BUCKS. ALL <br />ALL WOOD BEARING HEADERS TO BE #2 SYP (SIZES AS INDICATED ON PLAN) <br />MULLIONS SHALL CONFORM TO FBC REQUIREMENTS OF 1.5x THE DESIGN LOAD. <br />FRAMED GARAGE WALLS TO HAVE MIN 1/2" GYPSUM BIRD (IF AREA ABOVE <br />THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW TO BE A MIN. OF <br />GARAGE IS HABITABLE, USE 5/8" TYPE X GYPSUM BRD ON CLNG). <br />24" ABOVE FINISHED FLOOR WHERE THE OPENING OF THE OPERABLE WINDOW <br />IS LOCATED MORE THAN 72" ABOVE FINISHED GRADE OR THE SURFACE BELOW. <br />TRUSS ANCHORS <br />EXCEPT FOR WINDOWS WHOSE OPENINGS WONT ALLOW A 4" DIA. SPHERE TO <br />TRUSS TO BLK WALL CALCULATED FOR WORST CASE SCENERIO (1) SIMPSON <br />PASS AND OPENINGS THAT ARE PROVIDED WITH GUARDS COMPLY WITH ASTM F <br />HETA20 (OR EQUAL) EACH END EACH TRUSS CONNECTED w/(9) 10d NAILS <br />2006 OR ASTM F 2090. <br />EACH STRAP FOR (1) PLY OR HIP GIRDER. USE (2) SIMPSON HHETA20 EACH EN[ <br />(;ARA(;F nnop <br />FOR (2/3) PLY GIRDER USE (2) SIMPSON HHETA20 EACH END FOR GABLE END <br />GARAGE DOOR TO BE 140 MPH RATED (MIN +18.3/-20.4 PSF DWP) INSTALL <br />2x6 PT EA SIDE w/(3) 1/2"x8" "J" BOLTS w/2" WASHERS SPACED EQUALLY <br />ALONG LEGNTH EMBEDED INTO POURED CELLS (OPTION: MAY USE 1/2"x6" <br />WEDGE ANCHORS W/2" WASHERS) ANCHOR 2x6 PT ABOVE DOOR TO LINTEL W/ <br />WEDGE ANCHORS, CONCRETE SCREWS OR .145"0 P.D.F.'s A PERMANENT LABEL <br />IS REQUIRED AND THE INSTALLATION INSTRUCTIONS ARE REQUIRED TO BE <br />PROVIDED AND AVAILABLE ON THE JOB SITE AS WELL. THIS ADDITION ENABLES <br />ENABLES ASSURANCE OF COMPLIANCE <br />TRUSS, USE (1) SIMPSON HETA20 OR EQUAL UNLESS NOTED OTHERWISE <br />MISPLACED TRUSS STRAP IN THE CASE WHERE TRUSS STRAP IS MISSING THE <br />FOLLOWING METHOD MAY BE USED AS AN ALTERNATE. SUBSTITUTE A SIMPSON <br />MTS18 OR HUGHES RT18 TW (OR EQUIVALENT) FOR EACH HETA20-18 MISSED. <br />CONNECT TRAP TO BOND BEAM WITH (3) 3/16" X 1 3/4" HEX HEAD TAPCONS. <br />THIS SUBSTITU11ON IS GOOD FOR A MAXIMUM UPLIFT OF 1,000# PER STRAP. <br />ELECTRICAL NOTES <br />EXTERIOR PRE -HUNG DOORS <br />ELECTRICAL SYSTEMS AS INDICATED ON THESE PLANS ARE SCHEMATIC ONLY <br />1x DOOR BUCK (IF READ) TO BE ATTACHED TO MASONRY WALL w/1 1/2 x.106 <br />AND DESIGNS SHALL BE PREPARED IN ACCORDANCE WITH THE NATIONAL <br />ELECTRIC CODE (2008 NEC). <br />WIRE COLLATED NAILS ® 4"O.C. 2x DOOR BUCK (IF REQD) TO BE ATTACHED TO <br />SMOKE DET. LOCATED ON WALL 12" TO BOT. OF BOX OUT. VANITY LIGHTS <br />MASONRY WALL w/2 1/2x.106 WIRE COLLATED NAILS ® 4" O.C. SECURE PRE- <br />80" TO CENTER OF BOX OUT. FRONT DOOR GFI 4" OFF SLAB CENTER (SEE <br />HUNG DOOR UNIT PRE MFG SPECS. <br />PLAN FOR LOC.) TV & PHONE LOCATIONS PER COLOR SHEET. OTHER <br />ATTIC ACCESS <br />ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS <br />UNDER SINK. MICROWAVE PRE -WIRE. 1OKW & 5 TON - 6/2 ROMEX. FRONT <br />ATTIC ACCESS SHALL COMPLY WITH SECTION R807.1 WITH A MIN. OPENING OF <br />DOOR GFI 4" OFF SLAB CENTER (SEE PLAN FOR LOCATION) <br />22"00". <br />ALL ELECTRICAL AT SLIDING GLASS DOOR TO BE ON RIGHT HAND SIDE <br />EXTERIOR SIDING <br />REGUARDLESS OF GARAGE HANDING. <br />MIN 3/8" LP SMARTPANEL OR 7/16" OSB SHEATHING NAIL w/8d CC 6" O.C. <br />LATH <br />EDGES & 6" O.C. IN FIELDS <br />ALL ATTACHMENTS FOR SECURING WIRE LATH SHALL BE SPACED NOT <br />MISPLACED WALL RIENFORCING NOTE <br />MORE THAN 6" APART, AND SIDE LAPS SHALL BE SECURED TO SUPPORTS <br />AND BE TIED BETWEEN SUPPORTS NOT TO EXCEED 9". ALL METAL LATH <br />IN THE CASE WHERE A FOOTING DOWEL IS MISPLACED THE FOLLOWING <br />SHALL BE LAPPED 1" MIN. METAL WIRE LATH SHALL BE ATTACHED TO <br />EIVALENT <br />WOOD SUPPORTSOF <br />CORRECTION IS ACCEPTABLE: ADD A DOWNPOUR w/(1) #5 VERT REINFORCING <br />BENT OVER4ATG EASTI3ED <br />AIRSCAL WITH A PENETRATION OIFH3/4' ANDTHE <br />IN THE CORRECT ORIGINAL LOCATION. THE BAR SHALL BE TIED INTO THE BOND <br />STRANDS OF LATH. A BOND BREAK SHALL BE PROVIDED BETWEEN THE <br />BEAM w/ A MIN. HOOK OF 10". IF THE NEW DOWEL LOCATION IS MORE THAN 8" <br />WATER- RESISTIVE BARRIER & THE CEMENT PLASTER CONSISTING OF ONE <br />OFFSET FROM ORIGINAL LOCATION THE BOTTOM OF THE BAR SHALL HAVE A <br />OF THE FOLLOWING: TWO LAYERS OF AN APPRVD WATER-RESISTANT <br />BARRIER MATERIAL OR ONE LAYER OF AND APPVD WATER-RESISTANT <br />5x24 LONG DOWEL DRILLED 4 INTO THE CONCRETE SLAB & SET IN SIMPSON <br /># " <br />BARRIER OVER AN APPRVD PLASTIC HOUSE WRAP SHALL BE UNDER <br />SET EPDXY. IF LESS THAN 8" NO EPDXY NEEDED. CELL SHALL BE FILLED <br />WIRE LATH. <br />w/ A MIN. 2500 PSI CONCRETE. <br />FENESTRATION <br />FLASHING, SEALANTS, AND WEATHERSTRIPPING <br />JUNCTURE OF EXTERIOR PLASTER AND ANY FENESTRATION PRODUCT IS <br />ALL FENESTRATIONS PRODUCTS TO BE SEALED AT THE JUNCTURE OF THE REQD TO BE SEALED WITH A SEALANT COMPLYING WITH SECTION 612.12 <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C <br />920, ASTM C 1281, AA812, OR OTHER APPROVED STANDARD. <br />2X6 PLATE <br />CONTINUOUS 14' <br />LENGTHS MINIMUM <br />CONNECTED TO <br />CMU WALL W/1 /2" <br />X 8" ANCHOR BOLT <br />2-16d @ 32" O.C. <br />GABLE END TRUSS CONNECTION <br />STRUCTURALLY CONTINUOUS WALL <br />hinT Tn C`r'AI r <br />CONVENTIONAL VALLEY <br />FRAMING DETAIL <br />GABLE END, COMMON RIDGE BEAM <br />TRUSS OR GIRDER TRUSS - (SEE NOTE #6) <br />VALLEY RAFTERS <br />(24" O.C. MAX) <br />12 <br />P <br />TRUSS TYPICAL <br />(24" O.C.) POST SEE <br />NOTE #8) <br />CONSTRUCTION SEQUENCE (ALL MATERIAL 32 OR BETTER) TRUSS MUST <br />BE SHEATHED <br />1. INSTALL BASE TRUSSES. <br />2. APPLY SHEATHING TO TOP CHORD OF SUPPORTING TRUSSES. <br />IF SHEATHING IS NOT APPLIED, PROVIDE 2x4 PURLINS AT 24" O.C. <br />ON THE TOP CHORD OF THE SUPPORTING TRUSSES UNDER THE VALLEY <br />FRAMING. CONNECT PURLINS TO EACH TRUSS WITH (2) - 16d NAILS. <br />3. BRACE BOTTOM CHORD AND WEB MEMBERS PER TRUSS DESIGNS. <br />4. INSTALL 2 x 4 VALLEY PLATES. FASTEN TO EACH SUPPORTING TRUSS <br />WITH (2) 16d NAILS. <br />5. DEFINE VALLEY RIDGE BY RUNNING A LEVEL STRING FROM THE INTERSECTING <br />RIDGE OF THE (a.) GABLE END, (b.) GIRDER TRUSS OR (c.) COMMON <br />TRUSS TO ROOF SHEATHING. <br />6. SET 2 x 6 #2 RIDGE BEAM. SUPPORT WITH 2 x 4 POSTS SPACED 48" O.C. <br />BEVEL BOTTOM OF POST TO SET EVENLY ON THE SHEATHING. FASTEN POST <br />TO ROOF SHEATHING WITH (3) 10d TOE NAILS. <br />7. FRAME VALLEY RAFTERS FROM VALLEY PLATE TO RIDGE BEAM. MAXIMUM RAFTER <br />SPACING IS 24" O.C. FASTEN VALLEY RAFTER TO RIDGE BEAM WITH (3) 16d <br />NAILS. FASTEN VALLEY RAFTER TO VALLEY PLATE WITH (3) 16d TOE NAILS. <br />8. SUPPORT THE VALLEY RAFTERS WITH 2 x 4 POSTS 48" O.C. (OR LESS) ALONG <br />EACH RAFTER. INSTALL POSTS IN A STAGGERED PATTERN AS SHOWN ON PLAN <br />DRAWING. ALLIGN POSTS WITH TRUSSES BELOW. FASTEN VALLEY RAFTER TO <br />POST WITH (4) 10d NAILS. FASTEN POST TO SHEATHING WITH (3) 16d TOE <br />NAILS. FOR PURLIN APPLICATION, CONNECT 2x4 POST TO FACE OF TOP CHORD <br />WITH (4) 10D NAILS. <br />VALLEY PLATE <br />(SEE NOTE #4) <br />POST SEE <br />NOTE 8) <br />GABLE END, COMMON <br />TRUSS OR GIRDER TRUSS <br />LIVE LOAD = 30 PSF (MAX) <br />DEAD LOAD = 15 PSF (MAX) <br />D.O.L. INC. = 1.15 <br />ASCE 7-10 (MWFRS) 140 MPH <br />NOTE 48" O.C. MAXIMUM <br />POST SPACING <br />SHEET <br />