Laserfiche WebLink
CODE <br />FRAME <br />ROUGH OPENING <br />CODE <br />FRAME <br />ROUGH OPENING <br />12 <br />18 <br />5 <br />8 X <br />25 <br />1/2 <br />22 <br />36 <br />1/2 <br />X <br />25 1/2 <br />13 <br />1858X3778 <br />23 <br />36 <br />1/2 <br />X <br />37 7/8 <br />14 <br />1858X501 <br />8 <br />24 <br />361 <br />2X501 <br />8 <br />245 <br />36 <br />1/2 <br />X <br />55 1/2 <br />15 <br />18 <br />5 <br />8 X <br />62 <br />1/2 <br />25 <br />36 <br />1/2 <br />X <br />62 1/2 <br />EGRESS <br />16 <br />18 <br />5 <br />8 X <br />71 <br />1/2 <br />26 <br />36 <br />1/2 <br />X <br />71 1/2 <br />EGRESS <br />17 <br />18 <br />5 <br />8 X <br />83 <br />1/2- <br />27 <br />36 <br />1/2 <br />X <br />83 1/2 <br />EGRESS <br />1/2 32 <br />26X251 <br />2 <br />32 <br />5258X251 <br />2 <br />1/2 33 <br />26X3778 <br />33 <br />5258X3778 <br />1/2 34 <br />26X501 <br />8 <br />34 <br />5258X50 <br />i <br />8 <br />345 <br />52 <br />5 <br />8 X <br />55 1/2 <br />1 2 35 <br />26 <br />X <br />62 1/2 <br />35 <br />52 <br />5 <br />8 X <br />62 1/2 <br />EGRESS <br />1/2 36 <br />26 <br />X <br />71 7 <br />8 <br />36 <br />52 <br />5 <br />8 X <br />71 i Z2 <br />EGRESS <br />1/2 37 <br />26 <br />X <br />83 1 <br />8 <br />37 <br />52 <br />5 <br />8 X <br />83 1/2 <br />EGRESS <br />2024 <br />24 <br />X <br />28 <br />3050 <br />36 <br />X <br />60 <br />2030 <br />24 <br />X <br />36 <br />3060 <br />36 <br />X <br />72 <br />EGRESS <br />2040 <br />24 <br />X <br />48 <br />3424 <br />40 <br />X <br />28 <br />2050 <br />24 <br />X <br />60 <br />3430 <br />40 <br />X <br />36 <br />2060 <br />24 <br />X <br />72 <br />3440 <br />40 <br />X <br />48 <br />2424 <br />28 <br />X <br />28 <br />3450 <br />40 <br />X <br />60 <br />2430 <br />28 <br />X <br />36 <br />3460 <br />40 <br />X <br />72 <br />EGRESS <br />2440 <br />28 <br />X <br />48 <br />3824 <br />44 <br />X <br />28 <br />2450 <br />28 <br />X <br />60 <br />3830 <br />44 <br />X <br />36 <br />2460 <br />28 <br />X <br />72 <br />3840 <br />44 <br />X <br />48 <br />2824 <br />32 <br />X <br />28 <br />3850 <br />44 <br />X <br />60 <br />2830 <br />32 <br />X <br />36 <br />3860 <br />44 <br />X <br />72 <br />EGRESS <br />2840 <br />32 <br />X <br />48 <br />4024 <br />48 <br />X <br />28 <br />2850 <br />32 <br />X <br />60 <br />4030 <br />48 <br />X <br />36 <br />2860 <br />32 <br />X <br />72 <br />4040 <br />48 <br />X <br />48 <br />3024 <br />36 <br />X <br />28 <br />4050 <br />48 <br />X <br />60 <br />3030 <br />36 <br />X <br />36 <br />4060 <br />48 <br />X <br />72 <br />EGRESS <br />3040 <br />36 <br />X <br />48 <br />GENERAL NOTES <br />SUPPLEMENTAL NOTES <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR <br />THE BUILDING INSPECTORS USE. OR, ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED <br />FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />BEFORE REQUESTING THE FRAMING INSPECTION. <br />A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER <br />HEATER OR ELECTRIC PANEL. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDE WALLS. <br />IRRIGATION/ SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN <br />1'-O" OF THE BUILDING SIDE WALLS. <br />TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE <br />SHALL NOT BE LESS THAN 6 INCHES. EXCEPTION: PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS THAN <br />5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. <br />INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE. <br />SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED. <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH <br />PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL <br />ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. <br />MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL <br />OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. <br />CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR <br />SOIL TREATMENT. <br />SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-O" OF THE <br />STRUCTURE SIDEWALLS. <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING <br />LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE <br />RETREATED. <br />ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPT BY A LICENSED PEST CONTROL <br />COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL <br />STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS OF THE FLORIDA DEPT OF <br />AGRICULTURE AND CONSUMER SERVICES.' <br />AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN <br />1'-O" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING OR <br />OTHER CELLULOSE CONTAINING MATERIAL. <br />NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15'-0" OF <br />ANY BUILDING OR PROPOSED BUILDING. <br />MASONRY GENERAL NOTES STRUCTURAL DESIGN CRITERIA <br />1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD BUILDING CODE 1_ FBC FBCR 2014 <br />REQURRMENTS FOR CONCRETE MASONRY STRUCTURES (ACI 530-08). 2. ASCE/SEI 7-10 CODE (140 mph) <br />2. CONCRETE BLKS SHALL CONFORM TO ASTM C 90 (28 DAY STRENGTH=2000 3. STRUCTURE RISK CATEGORY = It <br />PSI, FM=1350 PSI) LAID IN RUNNING BOND. 4. ENVELOPE PROCEDURE FOR LOW RISE BUILDINGS <br />3. MORTAR SHALL BE TYPE S OR M. 5. EXPOSURE FACTOR = B <br />4. WHERE SHOWN, CELLS OF MASONRY BLOCK SHALL BE FILLED WITH CONCRETE 6. INTERNAL PRESSURE COEFFICIENT = t0.18 <br />WITH A MINIMUM COMPRESSIVE 'STRENGTH OF 3000 PSI AT 28 DAYS & 1-15, 7, 2nd FL LOADS: LIVE LOAD-40 PSF/DEAD LOAD-10 PSF <br />VERTICAL 8. ROOF LOADS: LIVE LOAD-20 PSF/DEAD LOAD-10 PSF <br />5. PROVIDE KNOCK -OUT IN CONCRETE MASONRY UNIT AT BASE OF EACH FILLED 9. COMPONENT & CLADDING WALL PRESSURE= (+35.3) (-47.2) PSF (MAX) <br />CELL TO ALLOW VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. ROOFING / FLASHING <br />DRAINAGE PROVIDE AN ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE ROOF DEAD LOAD - 7# P-S.F. ROOF LIVE LOAD - 20# P.S.F. ALL ROOF <br />COMPONENTS ARE PRE-ENGINEERED TRUSSES. ENG. WILL BE SUPPLIED TO <br />FOUNDATION, WHICH WAS NEEDED IN SITUATIONS LIKE "ZERO -LOT -LINE" FIELD INFECTOR AT TIME OF FRAMING INSPECTION (SEE TRUSS LAYOUT <br />CIRCUMSTANCES. THE ALTERNATIVE IS TO PROVIDE A MINIMUM OF 5� <br />SLOPE AWAY FROM THE FOUNDATION. PROVIDED.) ROOF SHEATHING NAILING SCHEDULE FOR 7/16' OSB ROOF <br />STEMWALL FOOTING DECK, USE 8d CC NAILS, SPACE 6' O.C. AT EDGES & 6" O.C. IN FIELDS. <br />STEMWALL FOOTING AS SHOWN ON WALL SECTION UP TO 36" HIGH CAN BE GAF SENTINEL/TIMBERLINE/CERTAINTEED FIBERGLASS SHINGLES SECURE <br />USED WITH UNBALANCED FILL UNBALANCED FILL GREATER THAN 36" SHALL BE wA5) NAILS PER SHINGLE ON UNDERLAYIMENT OVER 7/16" OSB ROOF <br />TEMPORARILY SUPPORTED DURING BACKFILLING & CONCRETE SLAB PLACEMENT DECK. PRODUCT MEETS ASTM D3462, D3161 F, D7158 G AND UL 997 <br />BY CONTRACTOR. THE MAXIMUM STEMWALL HEIGHT SHALL BE 10'-0' FOR WIND SPEEDS UP TO 140 MPH. FLASH ALL VALLEYS W/ MIN. <br />WINDOWS 16'x26GA VALLEY METAL PLACED OVER FELT NAILED 12" o.c. 0 EDGES. <br />WHERE WALLS MEET ROOF LINE, ALL FLASHING SHALL CONFORM TO FBC <br />ALL WINDOWS TESTED AND APPROVED IN ACCORDANCE WITH ANSI/AMMA/NWWDA REQUIREMENTS. UNDERLAYMENTS SHALL CONFORM WITH ASTM D226, ASTM <br />101/IS2 STANDARD AND LABELED AS SUCH. WINDOWS TO BE INSTALLED PER D4869, OR ASTM D6757. <br />MANUFACTURERS REQUIREMENTS FOR APPLICABLE DESIGN PRESSURE. WINDOWS <br />IN MASONRY WALLS SHALL BE ANCHORED THROUGH 1x BUCK INTO MASONRY. FRAMED WALLS <br />WINDOWS IN WOOD FRAMED WALLS MAY BE INSTALLED WITHOUT BUCKS. ALL ALL INTERIOR NON -BEARING WALLS MEET R6021.3.1. LUMBER TO BE <br />MULLIONS SHALL CONFORM TO FBC REQUIREMENTS OF 1.5x THE DESIGN LOAD. STD FF OR HIGHER GRADE. <br />THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW TO BE A MIN. OF ALL INTERIOR FRAMED BEARING WALLS TO BE #2 SPF. <br />24' ABOVE FINISHED FLOOR WHERE THE OPENING OF THE OPERABLE WINDOW ALL WOOD BEARING HEADERS TO BE #2 SYP (SIZES AS INDICATED ON PLAN) <br />IS LOCATED MORE THAN 72' ABOVE FINISHED GRADE OR THE SURFACE BELOW. FRAMED GARAGE WALLS TO HAVE MIN 1/2' GYPSUM BRD (IF AREA ABOVE <br />EXCEPT FOR WINDOWS WHOSE OPENINGS WONT ALLOW A 4' DIA. SPHERE TO <br />PASS AND OPENINGS . THAT ARE PROVIDED WITH GUARDS COMPLY WITH ASTM F GARAGE IS HABITABLE, USE 5/8" TYPE X GYPSUM BRD ON CL.NG). <br />2006 OR ASTM F 2090. TRUSS ANCHORS <br />GARAGE DOOR TRUSS TO BLJK WALL CALCULATED FOR WORST CASE SCENERIO (1) SIMPSON <br />GARAGE DOOR TO BE 140 MPH RATED (MIN +18.3/-20.4 PSF DWP) INSTALL HETA20 (OR EQUAL) EACH END EACH TRUSS CONNECTED w/(9) 10d NAILS 0 <br />2x6 PT EA SIDE w/(3) 1/2'x8' 'J' BOLTS w/2" WASHERS FACED EQUALLY EACH STRAP FOR (1) PLY OR HIP GIRDER. USE (2) SIMPSON HHETA20 EACH END <br />ALONG LEGNTH EMBEDED INTO POURED CELLS (OPTION: MAY USE 1/2"x6' FOR (2/3) PLY GIRDER. USE (2) SIMPSON HHETA20 EACH END FOR GABLE END <br />WEDGE ANCHORS W/2' WASHERS) ANCHOR 2x6 PT ABOVE DOOR TO LINTEL W/ TRUSS, USE (1) SIMPSON HETA20 OR EQUAL UNLESS NOTED OTHERWISE <br />WEDGE ANCHORS, CONCRETE SCREWS OR .145'0 P.D.F.'s A PERMANENT LABEL MISPLACED TRUSS STRAP IN THE CASE WHERE TRUSS STRAP IS MISSING THE <br />IS REQUIRED AND THE INSTALLATION INSTRUCTIONS ARE REQUIRED TO BE <br />PROVIDED AND AVAILABLE ON THE JOB SITE AS WELL. THIS ADDITION ENABLES FOLLOWING METHOD MAY BE USED AS AN ALTERNATE. SUBSTITUTE A SIMPSON <br />ENABLES ASSURANCE OF COMPLIANCE MTS18 OR HUGHES RT18 TW (OR EQUIVALENT) FOR EACH HETA20-18 MISSED. <br />EXTERIOR PRE -HUNG DOORS CONNECT TRAP TO BOND BEAM WITH (3) 3/16' X 1 3/4' HEX HEAD TAPCONS. <br />THIS SUBSTITUTION IS GOOD FOR A MAXIMUM UPLIFT OF 1,000# PER STRAP. <br />1x DOOR BUCK (IF READ) TO BE ATTACHED TO MASONRY WALL w/1 1/2 x.106 WIRE COLLATED NAILS 0 4'O.C. 2x DOOR BUCK (IF READ) TO BE ATTACHED TO ELECTRICAL NOTES <br />MASONRY WALL w/2 1/2006 WIRE COLLATED NAILS 0 4" O.C. SECURE PRE- ELECTRICAL SYSTEMS AS INDICATED ON THESE PLANS ARE SCHEMATIC ONLY <br />HUNG DOOR UNIT PRE MFG SPECS. AND DESIGNS SHALL BE PREPARED IN ACCORDANCE WITH THE NATIONAL <br />ELEATTIC ACCESS SMOKE IDET.LOCATED ONCWALL 12' TO BOT. OF BOX OUT. VANITY LIGHTS <br />ATTIC ACCESS SHALL COMPLY WITH SECTION R807.1 WITH A MIN. OPENING OF 80' TO CENTER OF BOX OUT. FRONT DOOR GA 4' OFF SLAB CENTER (SEE <br />22'x30'. PLAN FOR LOC.) TV & PHONE LOCATIONS PER COLOR SHEET. OTHER <br />ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS <br />EXTERIOR SIDING UNDER SINK. MICROWAVE PRE -WIRE. 1OKW & 5 TON - 6/2 ROMEX. FRONT <br />MIN 3/8" LP SMARTPANEL OR 7/16' OSB SHEATHING NAIL wJ8d CC 6O.C. DOOR GA 4" OFF SLAB CENTER (SEE PLAN FOR LOCATION) <br />ALL ELECTRICAL AT SLIDING GLASS DOOR TO BE ON RIGHT HAND SIDE <br />EDGES & 6" O.C. IN FIELDS REGUARDLESS OF GARAGE HANDING. <br />MISPLACED WALL RIENFORCING NOTE USE OF AFCI RECEPTACLES AND TAMPER <br />RESISTANT RECEPTACLES <br />IN THE CASE WHERE A FOOTING DOWEL IS MISPLACED THE FOLLOWING LATH <br />CORRECTION IS ACCEPTABLE: ADD A DOWNPOUR w/(1) #5 VERT REINFORCING ALL ATTACHMENTS FOR SECURING WIRE LATH SHALL BE SPACED NOT <br />IN THE CORRECT ORIGINAL LOCATION. THE BAR SHALL BE TIED INTO THE BOND MORE THAN 6' APART, AND SIDE LAPS SHALL BE SECURED TO SUPPORTS <br />BEAM w/ A MIN. HOOK OF 10'. IF THE NEW DOWEL LOCATION IS MORE THAN 8' AND BE TIED BETWEEN SUPPORTS NOT TO EXCEED 9'. ALL METAL LATH <br />OFFSET FROM ORIGINAL LOCATION THE BOTTOM OF THE BAR SHALL HAVE A SHALL BE LAPPED 1" MIN. METAL WIRE LATH SHALL BE ATTACHED TO <br />#5x24' LONG DOWEL DRILLED 4' INTO THE CONCRETE SLAB & SET IN SIMPSON VERTICAL <br />W AO SUPPPENETRORTS WITH OF 3TH� EQUIVALENT <br />BENT OF 4d (.EAST GALVANIZED <br />SET EPDXY. 5 LESS THAN $' NO EPDXY NEEDED_ CELL SHALL BE FILLED STRANDS OF LATH. A BOND BREAK SHALL BE PROVIDED BETWEEN THE <br />w/ A MIN. 2500 PSI CONCRETE. WATER- RESISTIVE BARRIER & THE CEMENT PLASTER CONSISTING OF ONE <br />FLASHING, SEALANTS, AND WEATHERSTRIPPING OF THE FOLLOWING: TWO LAYERS OF AN APPRVD WATER-RESISTANT <br />BARRIER MATERIAL OR ONE LAYER OF AND APPVD WATER-RESISTANT <br />ALL FENESTRATIONS PRODUCTS TO BE SEALED AT THE JUNCTURE OF THE BARRIER OVER AN APPRVD PLASTIC HOUSE WRAP SHALL BE UNDER <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C WIRE LATH. <br />920, ASTM C 1281, AA812, OR OTHER APPROVED STANDARD. FENESTRATION <br />LOAD -BEARING <br />PRESSURE <br />CLASS OF MATERIAL <br />(LBS. PER SO/FT) <br />CRYSTALLINE BEDROCK <br />12,000 <br />SEDIMENTARY AND FOLIATED ROCK <br />4,000 <br />SANDY GRAVEL AND/OR GRAVEL <br />3,000 <br />(GW AND GP) <br />SAND, SILTY SAND, CLAYEY SAND, <br />2,000 <br />SILTY GRAVEL AND CLAYEY GRAVEL <br />(SW,SP,SM,SC.GM AND GC) <br />CLAY, SANDY CLAY, SILTY CLAY, <br />1,500 <br />CLAYEY SILT, SILT AND SANDY SILT <br />(CL,ML,MH AND CH) <br />JUNCTURE OF EXTERIOR PLASTER AND ANY FENESTRATION PRODUCT IS <br />READ TO BE SEALED WITH A SEALANT COMPLYING WITH SECTION 612.12 <br />PLUMBING <br />ON MONO SLABS THE SEWER AND HVAC CONDENSATE LINE WILL GO <br />UNDER THE FOOTER, ON A STEM WALL THE LINES WILL GO THROUGH THE <br />BLOCK FOR THE LINE THAT PASSES THROUGH IT WILL BE SLEEVED WITH <br />A PIPE TWICE THE SIZE OF IT 3' WILL BE SLEEVED WITH 6' AND 3/4' WILL BE <br />SLEEVED WITH 1 1/2'. <br />SINGLE DOOR <br />FL# <br />CODE <br />VERSION <br />STATUS <br />MANUFACTURER <br />CATEGORY <br />SUB <br />CATEGORY <br />PRODUCT MODEL <br /># OR NAME <br />PRODUCT <br />DESCRIPTION <br />11827 R8 <br />2014 <br />APPR�P <br />MI WINDOWS AN9 <br />BOORS - <br />WINB()W5 -SINGLE <br />HUN6 <br />ALUMINUM 511 WINDOW <br />RESISTANT GEAZING <br />15585.1 <br />2014 <br />APPRVD <br />CROFT LLC <br />WINDOWS <br />SINGLE HUNG <br />96 SERIES <br />SINGLE HUNG <br />ALUMINUM SH WINDOW <br />16079.1 <br />2014 <br />APPRVD <br />CROFT LLC <br />EXTERIOR <br />DOORS <br />SLIDING EXT <br />DOOR <br />ASSEMBLIES <br />3000 SERIES <br />SLIDING GLASS DOOR <br />17680.2 <br />2014 <br />APPRVD <br />UNITED STEEL <br />PRODUCTS COMPANY <br />STRUCTURAL <br />COMPONENTS <br />WOOD CONNECTOR <br />ANCHORS <br />10655-R3 <br />2014 <br />APPRVD <br />SIMPSON STING -TIE <br />COMPANY <br />STRUCTURAL <br />COMPONENTS <br />WOOD CONNECTOR <br />ANCHORS <br />1774-R4 <br />2014 <br />APPRVD <br />COMMERCIAL CONIC <br />COMPANY <br />STRUCTURAL <br />COMPONENTS <br />PRECAST PRE- <br />STRESSED <br />LINTELS <br />8" &12" LINTELS <br />158.1 <br />2014 <br />APPRVD <br />CAST CRETE <br />CORPORATION <br />STRUCTURAL <br />COMPONENTS <br />HIGH STREGTH <br />CONCRETE <br />LINTELS <br />4", 6", 8" AND 12" <br />WIDE LINTELS <br />4904-R7 <br />2014 <br />APPRVD <br />MASONITE <br />INTERNATIONAL <br />EXTERIOR <br />DOORS <br />SWINGING EXT <br />DOOR ASSEMBLIES <br />STEEL DOOR WITH <br />OR WITHOUT SIDELITES <br />444.1 <br />2014 <br />APPRVD <br />CERTAINTEED <br />CORPORATION <br />ROOFING <br />ASPHALT <br />SHINGLES <br />3-TAB / ARCH <br />LAMINATED <br />SHINGLE <br />075-R7 <br />2014 <br />APPRVD <br />FL METAL PRODUCT <br />COMPANY INC <br />ROOFING <br />ROOFING <br />ACCESSORIES <br />RIDGE VENT <br />5219.1-R2 <br />2014 <br />APPRVD <br />TAMCO <br />ROOFING <br />ROOFING <br />ACCESSORIES <br />OFF RIDGE VENT <br />15279.20 <br />2014 <br />APPRVD <br />CLOPAY BLDG <br />PRODUCTS CO <br />EXTERIOR <br />DOORS <br />SECTIONAL EXT <br />DOOR ASSEMBLIES <br />WINDCODE W4 <br />GARAGE DOOR <br />13389.1 <br />2014 <br />APPRVD <br />CERTAINTEED <br />CORPORATION <br />PANEL WALLS <br />SOFFITS <br />VINYL SOFFITS <br />13192 <br />2014 <br />APPRVD <br />Worries Hardie,Incc_ building <br />PANEL WALLS <br />SIDING <br />SIDING <br />DOUBLE DOOR SINGE DOOR W/ SDLT SINGLE DOOR W/(2) SDLTS <br />EXTERIOR PRE -HUNG DOORS <br />SECURE PRE -HUNG DOOR UNIT <br />USE #10 WOOD SCREWS/TAPCONS <br />USE SIMPSON 1/4" X 1 1/2" MIN NAILON PINS AT THRESHOLD <br />DOOR INSTALATION/FASTENER PLACEMENT <br />NOT TO SCALE <br />ROOF PITCH <br />PER ELEVATION <br />----CONNECT BEAM TO TRUSS <br />W/SIMPSON MTS12. <br />I U.N.O. <br />I 2 SYP BEAM (SIZE PER <br />PLAN) STRAP W/(1) SIMPSON <br />HETA20 <br />ALL CELLS THAT FLOOR <br />PLAN INDICATES REBAR <br />SHALL BE CONCRETE FILLED. <br />CMU COLUMN AT FRONT <br />ENTRY PORCH W/15 <br />VERTICAL (COLUMN HEIGHT <br />PER ELEVATION) (COLUMN <br />SIZE & REBAR PLACEMENT <br />PER FLOOR PLAN) <br />FOOTING DOWELS: <br />2-15 EMBED. 6" MIN. <br />INTO FTG. W/ 90• HOOK <br />PAD PER FOUND PLAN <br />MASONRY COLUMN DETAIL <br />W/UPSET BEAM (ENTRY) <br />NOT TO SCALE <br />ROOF PITCH <br />PER ELEVATION <br />;ID,'I I TRUSS STRAP PER <br />11J GENERAL NOTES <br />PRECAST LINTEL W/(1 5 <br />(T&B) CONTINUOUS SPA <br />BETWEEN COLUMNS W/MIN. <br />8" BEARING SURFACE <br />EACH END CAP <br />ALL CELLS THAT FLOOR <br />PLAN INDICATES REBAR <br />SHALL BE CONCRETE FILLED. <br />' \-CMU COLUMN AT FRONT <br />ENTRY PORCH W/#5 <br />VERTICAL. COLUMN HEIGHT <br />PER ELEVATION) (COLUMN <br />SIZE & REBAR PLACEMENT <br />PER FLOOR PLAN) <br />FOOTING DOWELS: <br />2-#5 EMBED. 6' MIN. <br />INTO FTG. W/ 90' HOOK <br />'s PAD PER FOUND PLAN <br />MASONRY COLUMN DETAIL <br />W/PRECAST LINTEL <br />NOT TO SCALE <br />26 GA VALLEY METAL <br />(SEE GENERAL NOTES <br />FOR NAIL PATTERN) <br />ROOF DECK <br />W/15# FELT <br />-SHINGLES <br />NOTES TYPICAL <br />EACH SIDE <br />/ <br />VALLEY FLASHING <br />DETAIL <br />NOT TO SCALE <br />SIDING <br />METAL <br />FLASHING <br />c� <br />SHINGLE <br />a <br />N ROOF CEMENT <br />ROOF DECK <br />FLASHING DETAIL <br />MOTTO SCALE <br />ROOF VENTILATION CALCULATIONS <br />FLORIDA BUILDING CODE 2014 <br />SECTION 806.2 - 1/392ga C, <br />TOTAL ATTIC SPACE - 673.92 <br />NET FREE VENT NEEDED - 3.00 <br /># OF RIDGE VENTS - NA <br /># OF OFF RIDGE VENTS - <br />COMPONENTS <br />FLORIDA <br />SECTION <br />AND CLADDING <br />BUILDING CODE 2014 <br />301.2 140 MPH <br />NO- <br />ZONE <br />EFFECTIVE <br />WIND AREA <br />DESIGN WIND <br />PRESSURE <br />A <br />4 <br />10 <br />+35.3/-38.2 <br />B <br />4 <br />20 <br />+33.7/-36.7 <br />C <br />4 <br />50 <br />+31.6/-34.6 <br />D <br />4 <br />100 <br />+30.0/-33.0 <br />AA <br />5 <br />10 <br />+35.3/-47.2 <br />BB <br />5 <br />20 <br />+33.7/-44.0 <br />CC <br />5 <br />50 <br />+31.6/-39.8 <br />DO <br />5 <br />100 <br />+30.0/-36.7 <br />TYPICAL EXAMPLES <br />A <br />1/2 <br />32, 1/2 33, 1/2 34, <br />22 <br />B <br />1/2 <br />SH <br />35, 1/2 36, ALL SH <br />32-34. 3-0 DOOR OR <br />2_ <br />LESS <br />C <br />SH <br />35, 36, 5-0 OR 6-0 <br />SGD <br />8-0 SGD, 8-0 OHD <br />16-0 X <br />7-0 OHD < +22.0/-26.9 <br />IOOE <br />"S4 <br />o ) <br />12 <br />191 x26 <br />20X2618 <br />13 <br />191 X 38 3 <br />20X381 2 <br />14 <br />191 X505 <br />20X5034 <br />15 <br />t9 1 X 63 <br />20 X 63 1 8 <br />16 <br />191 X72 <br />20X721 8 <br />17 <br />19 1 X 84 <br />20 X 84 1 8 <br />1 2 32 <br />26 1 x 26 <br />27 3 X 26 1 <br />1233 <br />261 x383 <br />273 x3812 <br />1 234 <br />261 X 50 5 <br />273 X5034 <br />1 2 <br />26 1 X 63 <br />7 X 1 <br />1 2 36 <br />26 1 X 72 <br />27 3 X 72 1 <br />1 2 37 <br />26 1 X 84 <br />27 3 X 84 1 <br />22 <br />36 X 26 <br />27 3 X 26 1 <br />23 <br />36 X 38 3 <br />37 7 x 38 1 <br />24 <br />16 10 <br />377 X5034 <br />245 <br />36 X 50 1 4 <br />Sl 7 X 56 3 <br />25 <br />37 x 63 E <br />37 7 X 63 1 <br />26 <br />37 X 72 E <br />37 7 X 72 t <br />27 <br />37 X 84 E <br />37 7 X 84 1 <br />485 <br />48 X 63 <br />49 X 63 1 8 <br />32 <br />53 1 X 26 <br />54 X 26 t 8 <br />33 <br />53 1 X 38 3 <br />54 X 38 1 2 <br />34 <br />531 X 50 5 <br />54X5034 <br />345 <br />53 1 x 50 1/4 <br />54 X 56 3 8 <br />35 <br />53 1 X 63 E <br />54 x 63 1 8 <br />35 <br />53 1 X 72 E <br />54 x 72 1 8 <br />37 <br />53 1 x 84 E <br />54 x 84 18 <br />M Q µ,�,�1 .MX5 WCE1181 W 1 NALX OPOOK 5CE <br />A10 AM (1)`ACRMi W= SIZE FOR 61n1 - .oCt <br />CODE <br />SLIDING GLASS <br />6W <br />BLOCK <br />MEMING <br />SIZE FR" <br />WEMING <br />1/4 : 0 1/4 <br />n V4. n <br />"!•� <br />I O <br />1/41 0 1/4 <br />73 V4. n <br />1/4 1 0 1 <br />pV4. n <br />10 SA 1 0 <br />M t/e Y 0 1/4 <br />wt . n <br />19. 5A I 0 IM <br />7/& 1 0 1/4 <br />IV . In <br />10"10 1417AI <br />O1/4 <br />u6 3A.n <br />bm "M <br />Vol <br />m7/llty <br />m 4M .n <br />CONVENTIONAL VALLEY <br />FRAMING DETAIL <br />GABLE END, COMMON RIDGE BEAM <br />TRUSS OR GIRDER TRUSS -7(SEE NOTE 16) <br />VALLEY RAFTERS <br />(24- O.C. MAX) <br />12 <br />P <br />TRUSS TYPICAL <br />(24` O.C_) POST {SEE <br />NOTE #8) <br />CONSTRUCTION SEQUENCE (ALL MATERIAL 32 OR BETTER) TRUSS MUST <br />BE SHEATHED <br />1. INSTALL BASE TRUSSES. <br />2. APPLY SHEATHING TO TOP CHORD OF SUPPORTING TRUSSES. <br />IF SHEATHING IS NOT APPLIED, PROVIDE 2x4 PURUNS AT 24' O.C_ <br />ON THE TOP CHORD OF THE SUPPORTING TRUSSES UNDER THE VALLEY <br />FRAMING. CONNECT PURUNS TO EACH TRUSS WITH (2) - 16d NAILS. <br />3. BRACE BOTTOM CHORD AND WEB MEMBERS PER TRUSS DESIGNS. <br />4. INSTALL 2 x 4 VALLEY PLATES. FASTEN TO EACH SUPPORTING TRUSS <br />WITH (2) 16d NAILS_ <br />5. DEFINE VALLEY RIDGE BY RUNNING A LEVEL STRING FROM THE INTERSECTING <br />RIDGE OF THE (a.) GABLE END, (b.) GIRDER TRUSS OR (c.) COMMON <br />TRUSS TO ROOF SHEATHING. <br />6. SET 2 x 6 #2 RIDGE BEAM. SUPPORT WITH 2 x 4 POSTS SPACED 48' O.C. <br />BEVEL BOTTOM OF POST TO SET EVENLY ON THE SHEATHING. FASTEN POST <br />TO ROOF SHEATHING WITH (3) lad TOE NAILS. <br />7. FRAME VALLEY RAFTERS FROM VALLEY PLATE TO RIDGE BEAM. MAXIMUM RAFTER <br />SPACING IS 24' O.C. FASTEN VALLEY RAFTER TO RIDGE BEAM WITH (3) 16d <br />NAILS_ FASTEN VALLEY RAFTER TO VALLEY PLATE WITH (3) 16d TOE NAILS. <br />8. SUPPORT THE VALLEY RAFTERS WITH 2 x 4 POSTS 48' O.C. (OR LESS) ALONG <br />EACH RAFTER. INSTALL POSTS IN A STAGGERED PATTERN AS SHOWN ON PLAN <br />DRAWING. ALUGN POSTS WITH TRUSSES BELOW. FASTEN VALLEY RAFTER TO <br />POST WITH (4) 10d NAILS_ FASTEN POST TO SHEATHING WITH (3) 16d TOE <br />NABS. FOR PURUN APPUCATION, CONNECT 2x4 POST TO FACE OF TOP CHORD <br />WITH (4) 10D NAILS. <br />VALLEY PLATE <br />(SEE NOTE 14) <br />POST SEE <br />NOTE 8) <br />GABLE END, COMMON <br />TRUSS OR GIRDER TRUSS <br />LIVE LOAD = 30 PSF (MAX) <br />DEAD LOAD 15 PSF (MAX) <br />D.O.L. INC. 1.15 <br />ASCE 7-10 (MWFRS) 140 MPH <br />NOTE 48' 0_C. MAXIMUM <br />POST SPACING <br />6 /f� /1, 5 <br />PLANS DESIGNED 81 ENGINEERED <br />IN ACCORDANCE w/ FLORIDA <br />BUILDING CODE 2014 5TH EDITHON <br />REV DATE <br />1 - <br />2 - <br />3 - <br />J <br />o <br />'J <br />0 <br />o <br />z <br />L li <br />a <br />z <br />0 <br />02 <br />ZLL+ <br />" z <br />W <br />N <br />en o <br />W ~ co <br />dLL un. <br />O <br />aC <br />N <br />G1 s � Lo <br />8�aT <br />U <br />U <br />" <br />J <br />3 1 o€ <br />ui ul <br />c�"Q�' <br />U <br />� <br />w <br />O Z r E <br />=.- <br />u) <br />ui <br />v a c� <br />>� <br />e� <br />W <br />� <br />E­4 <br />O <br />co <br />IMM <br />C <br />W <br />W <br />c <br />O <br />F-4 <br />W <br />W <br />� <br />H <br />O'J <br />Q) <br />E <br />O o <br />� O <br />w <br />� tL <br />a z <br />O Y <br />�L LL g <br />ZZ O C> <br />0 <br />• 1--�I o <br />DRAWN <br />CAM <br />CHECKED <br />CL <br />DATE <br />8-17-15 <br />SCALE <br />NOTED <br />JOB No. <br />2895-2-0 <br />SHEET <br />4 <br />t <br />N <br />