Laserfiche WebLink
I: I I I 1 II II I.'i.- I._LI <br />1 1 I I I I I. I I _ L. _- I <br />HVAC PLAN <br />CU 1 <br />VERIFY EXACT <br />CONDENSER UNIT <br />LOCATION WITH JOB <br />SUPER ON SITE <br />HVAC NOTES/SYMBOLS: <br />ALL CONSTRUCTION SHALL COMPLY WITH LOCAL <br />BUILDING CODES AND THE STATE ENERGY CODE. <br />OBTAIN REQUIRED PERMITS AND INSPECTIONS. THE <br />MECHANICAL INSTALLER IS TO VERIFY ALL <br />CLEARANCES AND ACCESS SPACE BEFORE <br />FABRICATION OR INSTALLATION OF ANY HVAC WORK. <br />INSTALL HVAC EQUIPMENT PER MANUFACTURERS <br />RECOMMENDATION, DUCT BOARD EQUAL TO KNAUF <br />1/2". R-6, INSTALLED PER MANUFACTURERS <br />INSTRUCTIONS. FLEXIBLE DUCT WORK EQUAL TO <br />ATCO 76, R-6, CLASS 1 AIR DUCT. SEAL ALL <br />DUCTWORK PER UL181P. PROVIDE A FIRE STAT IN <br />THE RETURN AIR PLENUM OF ALL AIR HANDLING <br />UNITS. MOUNT THERMOSTAT 60" ABOVE FLOOR. <br />CONDENATE DRAIN LINE TO SPILL ON GRASS. G.C. <br />TO PROVIDE UNDERSLAB DRAINS, CHASES, AND AIR <br />HANDLER PLATFORMS. <br />_ EXHAUST _ EXHAUST FAN <br />® FAN + LIGHT <br />OO = THERMOSTAT, MOUNTED AT 60" All <br />®= LENGHT OF DUCTWORK IN FEET <br />_ AIR MIXING BOX HEIGHT <br />12x 17x 17xHEIGHT A=15" <br />B=17" <br />_ AIR MIXING BOX C=19" <br />14x16x16x12xHEIGHT D=15" <br />E=15" <br />CARRIER SPLIT FURNACE <br />AIR HANDLER MARK: <br />AHU <br />UNIT MODEL NUMBER: <br />58CVAl10 <br />SUPPLY FAN CFM/SP: <br />1600/.4 <br />SUPPLY FAN HP: <br />1/2 <br />UNIT VOLTAGE: <br />120/1/60 <br />UNIT DIMENSIONS HWD: <br />33x21 x29 <br />UNIT WEIGHT: <br />140 LBS <br />COIL MODEL: <br />CNPVP4821ACA <br />EXPANSION VALVE: <br />CONDENSER MARK: <br />CU <br />UNIT MODEL NUMBER: <br />24ABA34BA003 <br />UNIT VOLTAGE: <br />208/230/1/60 <br />UNIT MCA/BREAKER: <br />27/40 <br />UNIT DIMENSION HWD: <br />28x3Ox30 <br />UNIT WEIGHT: <br />203 LBS <br />TOTAL COOLING BTUH: <br />46,000 <br />SENSIBLE COOLING BTUH: <br />34,800 <br />TOTAL HEATING BTUH: <br />110,000 <br />SEER/AFUE <br />13.5/0.8 <br />CARRIER SPLIT HEAT PUMP <br />AIR HANDLER MARK: <br />AHU <br />UNIT MODEL NUMBER: <br />FV4BNF005 <br />SUPPLY FAN CFM/SP: <br />875-1400 / .4 <br />SUPPLY FAN HP: <br />1/2 <br />UNIT VOLTAGE: <br />208/230/1/60 <br />UNIT DIMENSIONS HWD: <br />54x22x23 <br />UNIT WEIGHT: <br />172 LBS <br />HEATSTRIP KW: <br />10 <br />HEATSTRIP MCA/BRKR: <br />58.5/60 <br />CONDENSER MARK: <br />CU <br />UNIT MODEL NUMBER: <br />25HBA348AO03 <br />UNIT VOLTAGE: <br />208/230/1/60 <br />UNIT MCA/BREAKER: <br />27/40 <br />UNIT DIMENSION HWD: <br />310505 <br />UNIT WEIGHT: <br />265 LBS <br />TOTAL COOLING BTUH: <br />47,000 <br />SENSIBLE COOLING BTUH: <br />35,700 <br />TOTAL HEATING BTUH: <br />47,500 <br />SEER/HSPF <br />14.0 / 8.6 <br />SCALE: <br />1/8" -1' • 11x17 OWBLACKPOINT <br />1/4' - 1' a 22x34 ENABLED <br />U <br />z <br />Q <br />IIn <br />SOU <br />m <br />-�-� <br />J <br />J <br />LL <br />j <br />W9a <br />Z <br />ME <br />ZQ <br />m <br />W <br />U <br />O <br />J <br />LE <br />w <br />O <br />W <br />J <br />j <br />Z) <br />2 <br />2 <br />2 <br />3 <br />(1) <br />❑ ❑ ❑ ❑ ❑ <br />U <br />z <br />n <br />IL <br />o <br />w <br />> <br />Dw <br />O <br />w <br />V) <br />0 <br />c� <br />cr- <br />J <br />J <br />z <br />Q <br />0 <br />z <br />a <br />M <br />m <br />p <br />0 <br />0 <br />W <br />z <br />N Z <br />0 <br />`} <br />O <br />O <br />N n <br />_ <br />m <br />w <br />0 <br />Z <br />Q <br />% <br />0Z <br />� z <br />I <br />z <br />O <br />ISSUE DATE <br />JANUARY 2008 <br />DRAWN BY <br />SIMPAD <br />DESIGN BY <br />INLAND HOMES <br />REVISION DATE <br />01116113 <br />04123112 <br />05111111 <br />12131110 <br />08105110 <br />03111110 <br />SHEET <br />M <br />HVAC PLAN <br />