Laserfiche WebLink
�, , ,,.I r •, pq I r n I L I IL I I_I I'll i t <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER <br />SLOPE <br />0.3 in : 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />FRESISITIVE <br />BARRIER <br />TAPE EXTERIOR <br />WOOD FRAME CONSTR. <br />(0.6 cm : 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHIN 3/4"-1" BEAD OF CONSTR. <br />3 SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND <br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />(ASSEMBLED WINDOW) ._ 2 <br />NAIL BRAND OR EQUAL WEATHER <br />O <br />EXTERIOR <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />Ir <br />PROOF CAULKING <br />O <br />of draining to the exterior water that penetrates the exterior cladding. <br />WEATHER <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />' RESISITIVE <br />2 BARRIER <br />SEAL TOPS OF JOISTS <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />1 <br />UNDER DECKING SUBFLOOR <br />- <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />- SELF -ADHERED FLASHING <br />(SEE DETAIL WP07) <br />} _; , _ - �____ <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />._- <br />- - <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />HEAD FLASHING TIE-IN INSTRuxTIONs: <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />1. Cut, fold up & temporarily secure weather <br />RIM JOIST <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />THESE DETAILS ARE GENERIC AND <br />resistive barrier above header to allow for <br />flashing installation <br />MEANT TO SHOW GENERAL FLASHING <br />2. Self -adhered flashing plus head flashing under ,� <br />,� <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />2 <br />20 <br />wood -based sheathing, shall include awater-resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />flashing and seal with tape <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous lane and an flashing <br />P p Y p Y Y p p p Y 9 <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />ale: NTS <br />SELF -ADHERED FLASHING Sc■ <br />FLANGED WINDOW 1 <br />SELF -ADHERED FLASHING ■ <br />1 <br />SELF -ADHERED FLASHING ■ <br />, <br />Exception: Where the barrier that is applied over wood -based sheathing has a water resistance <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILU POTSHELF/CHIMNEY SHOULDER <br />water -resistive <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />EXTERIOR SHEATHING <br />3/4"-V BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB &HEAD <br />NEEDED IN CORNERS ADHESIVE <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />3/8" CEMENT <br />PLASTER <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />pp g g pp <br />12 MIL DRYLOK CMU - MASONRY BLOCK <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />membranes used as flashing shall be applied in accordance with the manufacturers instructions. All flashing shall be applied in a manner to <br />EXTREME <br />REFER TO TECHNICAL <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />WINDOW <br />LETTER ON CHEMICAL <br />COMPATIBILITY ° <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FASTENER <br />1) SEALANT AT <br />SELF -ADHERED FLASHING ° <br />SELF -ADHERED FLASHING, <br />_ <br />-� t BEFORE FOLDING, SCORE <br />RELEASE PAPER TO <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />4) SEALANT JOINT � � �• °• � � WINDOW BUCK TO <br />° <br />EXTEND A MINIMUM 6" <br />AD ADHESIVE ASS OWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />OUTSIDE EDGE OF ' ' ,. • > MASONRY <br />WINDOW BUCK <br />° ° <br />OTTOM OF FROM <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />s• ' 2) SEALANT JOINT <br />"' <br />THRESHOLD <br />, <br />shall be installed at the following locations: <br />5) SEALANT FROM INSIDE EDGE OF <br />2 !' a <br />WINDOW FRAME WINDOW BUCK <br />ACROSS OW BUCK <br />SECTION -A (SEE DETAIL WP02) <br />AND EXTENNDD TO WINDOW FRAME <br />1.1.Exterior window and door openings. Flashin at exterior in s shall extend to the surface of the exterior wall <br />g or window andoor openings <br />MASONRY ATTACHED <br />PER CODE <br />sELF-ADHERED FLASHING <br />O <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />6) TOOLED SEALANT REQUIREMENTS, <br />BEAD BRIDGING <br />2 <br />following: <br />CLADDING AND WINDOW <br />FRAME <br />2 <" <br />SELF -ADHERED FLASHING <br />5 <br />1.1 The fenestration manufacturer's installation and flashin Instructions, or for lications not addressed in the fenestration <br />9 Pp <br />3) SEALANT WINDOW FRAME T <br />WINDOW BUCK ALL THE WAY <br />NAILING FLANGE <br />1 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashin instructions or details <br />g <br />(D <br />AROUND, INCLUDING SILL. <br />2 <br />SEAL TOPS OF JOISTS <br />6 <br />are <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />DO NOT FLASH OVER <br />BOTTOM NAILING 8 <br />UNDER DECKING <br />2 <br />7 <br />subsequent drainage. Openings usin an flashing shall incorporate flashing or protection at the head and sides. <br />q gg p g p g <br />FLANGE <br />(SEE DETAIL WP07) <br />(SEE <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />SELF -ADHERED FLASHING <br />■ 1 <br />SELF -ADHERED FLASHING <br />1 <br />SELF -ADHERED FLASHING <br />■ , <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />FENESTRATION INSTALLATION AND INTERFACE <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Conti nuously above all projecting wood trim. <br />SHEATHING <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL <br />Lath <br />APPROVED SHEATHING <br />SELF -ADHERED FLASHING <br />Sheathing <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />APPROVED HOUSEWRAP <br />PATCH <br />STRUCTALATH TWIN TRACK 2.5 <br />Stucco <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />° ° <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />DOUBLE <br />0 <br />° a ° ° <br />a ° <br />7/8" Cement Plaster <br />"V" SEALANT SOCKET WITH <br />JOIST <br />°° <br />° <br />TOOLED APPROVED SEALANT <br />SINGLE WOOD BEAM <br />■ <br />° <br />Foundation Walla <br />in accordance with 7/8" Cement Plaster <br />JOIST BELOW <br />1 SELF -ADHERED FLASHING <br />° <br />ASTMC926 in accordance with <br />SELF -ADHERED FLASHING <br />a <br />° ° °° ° <br />ASTMC926 <br />2 <br />° ° <br />° ° <br />Felt backed metal <br />^ _ <br />lathe in accordance Felt backed metal <br />SELF -ADHERED SELF -ADHERED <br />3" MIN <br />4 <br />, . <br />r with ASTM C1063 lathe in accordance <br />FLASHING FLASHING <br />O <br />5 <br />with ASTMC1063 <br />� Building Paper <br />Building Paper <br />7/16" O.S.B. <br />sheathing 7/16" O.S.B. <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING ■ ' <br />winMeta <br />SELF -ADHERED FLASHING ■ , <br />FOUNDATION WEEP SCREED ■' <br />l sheathing <br />l <br />' <br />EXTRUDED SHOULDER <br />DECK JOIST <br />OUTSIDE CORNER <br />Flashing <br />Weep Screed <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />� <br />Installed As Per <br />Manufact. Specs. <br />PRODUCTS DETAILS <br />STRIP OF SAF LEGEND � <br />I SELF ADHERED FLASHING (SAF) o <br />Maintain Stampede or similar <br />Bottom of bottom <br />TILE FINISH <br />DRAINAGE PLANE WRB DRAINAGE PLANE (DP) WEATHER RESISTANT <br />cauk <br />Weep Screed joint only <br />BARRIER (WRB) - <br />„ <br />1 1 /2„ t0 2 <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />1/2 DUROCK <br />" <br />> <br />BOND BREAK WEATHER RESISTANT BARRIER- <br />BOND BREAK WRB SELF FURRING (SF) LATH � <br />Above Roof Weep Screed <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />a <br />I PLASTER ACCESSORY <br />Sheathing Installed As Per <br />SF LATH SHEATHING,'OSB', PLYWOOD, DENSGLASS iaSSmS <br />Manufact. Specs. <br />1'-4" PER PLAN <br />? <br />Detail Instructions <br />1'-0" PER PLAN <br />= IT <br />I I WRAP DP WRB ONTO <br />� IC <br />IC <br />THE VERTICAL <br />1/2" Cementitious <br />Refer to the number marked as # In each detail that corresponds to the <br />SURFACE TOP OF <br />Cement Plaster Decorative Finish <br />numbered items in the list o Instructions below: <br />- <br />FLANGE AS AN AIR <br />in accordance <br />BARRIER <br />with ASTMC926 0 0, <br />b• • • o, All inside and <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />SLOPE <br />8 CMU E --- <br />-`� <br />I 3-1/2" INCH FLANGE <br />over wood2nd o•• o <br />.q'• outside corner will <br />floor �°'o•®,o, need to be miter <br />laps <br />4" OR 8" CMU - ° o <br />- _ _ _ _ = I <br />° ° cut and caulked all <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) ° <br />Z Z <br />STRUCTURAL FRAMING <br />°�o•o,• o• butt joints need to <br />' °'o.® <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT 8 <br />g g <br />(11 <br />STRUCTURAL SHEATHING <br />.0'0•' becaulked using <br />•' ® • <br />9 • Stampede sim. <br />embedded in the adhesive layer) - for ease of installation and to <br />= = <br />minimize scoring cuts <br />a ° <br />W Lu <br />D- O_ <br />PLASTER STOP THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. STRIP OF SAF <br />l <br />caulk for all <br />5. Remove all release paper per standard installation instructions and <br />a a <br />~ � <br />= cn <br />CONTINUOUS BACKER DO NOT SEAL - <br />DRAINAGE PLANE WRB <br />adhere to substrate using a square piece of flashing material (6" X 6" <br />° <br />U <br />ROD & SEALANT DRIP SCREED PLASTIC <br />Minimum) <br />° <br />SLOPED MUD BED ° <br />L<J W <br />= <br />ACCESSORY I BOND BREAK WRB <br />6. Fold as shown by arrows <br />° <br />Q W <br />LU <br />SF LATH <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />v 3: <br />fit tight to corner <br />_ <br />VINYL SHOWER PAN ° a ° ° a° <br />o <br />J <br />Note: <br />8. Mechanically fasten as necessary <br />SLO PE ° <br />_ <br />- - - - - - - - <br />The building paper and metal lath must be <br />d ° <br />Cement installed over the top of the weep screed. <br />PLASTER STOP A <br />Plaster <br />CONTINUOUS BACKER ROD <br />over block <br />4 4 4 4 <br />& SEALANT <br />1 st floor <br />< <br />CEMENTITIOUS FINISH <br />WEEP SCREED DETAIL <br />SHOWER SEAT ■ <br />SOFFIT/CANTILEVER ■ <br />SCALE: NOT TO SCALE <br />N <br />N <br />N <br />>F- <br />o <br />O <br />� W <br />s <br />>;- r- <br />X <br />cc O <br />y O l0 <br />6 r N � <br />d W <br />dr�� <br />•� <br />a� O � Q <br />is m w d <br />tII- O <br />`n E <br />c <br />A o <br />G. v <br />CV <br />CV <br />0 <br />CV <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />%) <br />E <br />j� <br />C 0 <br />0 <br />N <br />QN <br />�nF-� <br />M 2S j LL <br />C J W z LL . i a <br />� <br />Z- <br />a a. IC <br />t m$ <br />W <br />W <br />> �N(O o <br />W <br />� _ w <br />ul N O Q I- <br />F- <br />�Z <br />V <br />N <br />O U L) W <br />Z <br />W <br />❑ ❑ <br />O <br />z <br />Z� <br />Q <br />E3 <br />Ln <br />z v0 <br />0 o <br />4-J <br />(a <br />cn <br />w <br />Ua <br />O <br />g <br />C N <br />�N <br />y <br />U <br />E <br />I <br />4 <br />N <br />so <br />o <br />w <br />M <br />Cl) <br />i <br />o <br />Z <br />Z <br />LL <br />E <br />zo <br />oo <br />>n <br />0S <br />Ii <br />E <br />!E <br />Z <br />ap14 <br />wOW�' <br />E <br />0 <br />XoQ <br />QUg <br />'2ZZ�� <br />U <br />U� <br />wM' <br />rp <br />Q) <br />C <br />z <br />U <br />.2 <br />"m <br />m o <br />Z' <br />Oz <br />Z <br />__ <br />N J <br />Oro <br />aw <br />ern <br />N <br />N <br />`sue <br />Z <br />a <br />W <br />ci 3 <br />ao <br />o <br />ma <br />�3 <br />>O <br />5 <br />a <br />�3 <br />y0 <br />>M <br />� <br />0 <br />m <br />c� <br />00 <br />CU <br />:3 O <br />�. <br />< <br />- <br />co <br />O <br />� m <br />� <br />N <br />� <br />O <br />a) <br />"2 <br />"2 <br />M N <br />O <br />0 <br />0000 N <br />Lo <br />N <br />Q <br />I o <br />co <br />.-- <br />0 <br />,1 <br />j <br />Cl) <br />00 <br />0 <br />Z <br />M <br />Z <br />E T <br />tli <br />c <br />0. <br />E <br />U -J <br />Q pre <br />� <br />JOB <br />NO: <br />22-09406 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />