rr.ear.war�ww�.t.�,1�i,.,uruxY■7Wl�H�tru�IW ■ �1�� � I���I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />x14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 to WH <br />10 #8 to Range <br />#6 to HVAC <br />MAIN <br />-� <br />1 so=vo <br />200=410 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />jisoonnLe <br />Bare Cu Ground <br />BONDINGUNDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />V <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PDB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />❑TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />l� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" <br />Li <br />SWITCH <br />DISP( <br />Tl VTR <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />i <br />I C <br />KITCHE <br />DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />A/C PAD <br />GFI WP DISC. <br />A <br />/ I <br />I <br />11ENTRYWP <br />DB & GFI TO / GFI <br />BE ALIGNED — — — — — — — <br />VERTICALL <br />I <br />I <br />I <br />1 <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />li X <br />W LU <br />I_ o <br />LLJ Z J <br />07) <br />�UI=— <br />jo� <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / PER SPECS <br />FIRST FLOOR ELECTRICAL PLAN —A <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L----------- I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br />SECOND FLOOR ELECTRICAL PLAN -A <br />c� <br />ti <br />a <br />N <br />ao <br />N <br />F-- d <br />� W <br />O <br />c M C.) N <br />— m <br />y t0 c? .- <br />�y <br />.E m O J <br />..Er N Na <br />v <br />y <br />¢ c <br />Cu, <br />Cu, o <br />iv y 1n> in <br />y a <br />_E <br />�o <br />a � <br />0 <br />N <br />N <br />0 <br />N <br />O <br />00 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />fA <br />a $ <br />v cW0 n <br />r J <br />ni N M d. LL <br />LL W LL a <br />(� w <br />a <br />Z m = °' w <br />r 9_o <br />a' (d N tD <br />°f <br />to Zo m w Z NO Z - <br />I - <br />ILW <br />� <br />V N <br />OU 0 <br />Z <br />W El <br />M M <br />z N § <br />z 2 N <br />z � � <br />0 <br />< <br />N z <br />o <br />L <br />W � <br />o a <br />V <br />O LLJ 8 <br />N <br />v <br />f— E <br />el <br />U) <br />_o <br />¢ N 0Cn <br />so <br />w <br />Mz <br />o <br />z <br />J <br />L.L. <br />ce E <br />z <br />z 0 <br />� ¢' <br />> N <br />d o <br />E U <br />� <br />wj <br />Z0 <br />0a <br />Co410 <br />t <br />a <br />OSU <br />01 <br />ZiLqao <br />0 <br />oz <br />. <br />to <br />N Ca <br />z <br />m� <br />o <br />ZLL <br />Z <br />w <br />y <br />gz <br />Z o <br />Cn <br />g0 <br />g <br />X w <br />W <br />C) 3 <br />sir <br />=k <br />oLL <br />3 <br />o <br />GO <br />wT <br />0 <br />0 r <br />cl <br />z <3 <br />C <br />0 O <br />T <br />i. <br />W <br />m <br />to <br />m <br />0 <br />00 <br />c) 3 <br />Y <br />O <br />U m <br />N <br />L <br />,it <br />ICU N <br />O <br />0 <br />0000 CN <br />N <br />Q o <br />T <br />o <br />w M r <br />7 00 00 <br />o <br />Z <br />l0 <br />Z <br />N <br />E T d`ai <br />m <br />o <br />m <br />a <br />E a m <br />o <br />0 _j a o <br />JOB <br />NO: 22-09406 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />