My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36508 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36508 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:07:21 AM
Creation date
2/19/2025 9:10:53 AM
Metadata
Fields
Template:
Building Plans
Street #
36508
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5965
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV - ABOVE MLDG - MOULDING VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />AFF -ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING THE FOLLOWING TECHNICAL CODES SHALL APPLY: 1.0 PLAN REVISIONS CS COVER SHEET N <br />AHU -AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN N <br />N <br />A/C -AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 TYPICAL TRUSS CONNECTOR REVISION A2 1ST FLOOR PLAN <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 r,. <br />A3 2ND FLOOR PLAN <br />OC - ON CENTER 3.0 ELEVATION A ENTRY PORCH ROOF UPDATE F J <br />AT -ALUMINUM THRESHOLD <br />A4 ROOF PLANd, '• � <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 , <br />AVG -AVERAGE 4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A4. <br />" <br />1 2ND FLOOR FRAMING &ROOF PLAN o <br />OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME , ' <br />BM -BEAM A6 EST FLO00 <br />O RE <br />LEVATIONSBFE - BASE FLOOD ELEVATION OPP - OPPOSITE 1.6 GALLONS 5.0 ADDING K, L, M ELEVATIONS <br />ELECTRICAL PLAN`'- - � <br />OPT -OPTIONAL <br />a <br />BLK -BLOCK OH - OVER HANG A6.1 2ND FLOOR ELECTRICAL PLAN a <br />2. WATER - FLOW RATE. <br />BLDG - BUILDING A a <br />OH CABS- OVERHEAD CABS SNO STRUCTURAL NOTES <br />BRD -BOARD PNT - PAINT FINISH PUBLIC FACILITIES LAV 0.5 G.P.M. a <br />BRG -BEARING - Uj <br />PTD PAINTED SN1 STRUCTURAL NOTES <br />1 _-. �� e <br />PRIVATE FACILITIES LAV 2.2 G.P.M. S3M FOUNDATION DETAILS ` P <br />BTM -BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. S4 FRAME WALL DETAILS <br />BUC - BUILT UP COLUMN PERF -PERFORATED <br />r, <br />CAB -CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES S5 ROOF FRAMING DETAILS <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC S6 WALL SECTION DETAILS- - �- m �' w CLG - CEILING PKT -POCKET SS RETRO FIT DETAILS <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO ST STAIR DETAILS o <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S11 PRECAST DETAILS z <br />CL - CENTERLINE PSI - POUNDS PER SQUARE S12 PRECAST DETAILS <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA1.0 PRODUCT APPROVAL <br />CONC -CONCRETE PB - PUSH BUTTON CODE PA1.1 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA1.2 PRODUCT APPROVAL" N N E <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES > o N o <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 PA1.3 PRODUCT APPROVAL _� L u <br />PA1.4 PRODUCT APPROVAL M co�' <br />CTR -CENTER REQD - REQUIRED i� <br />CJ - CONTROL JOINT R/A - RETURN AIR Q HANDRAILS - CHAP. 3 PA1.5 PRODUCT APPROVAL N D O m a <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.0 HURRICANE SHUTTERS r m <br />DTL - DETAIL RS - ROUGH SAWN <br />Q GUARDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS � ° 0 0 2 o <br />DIA - DIAMETER SC - SOLID CORE SH 1.2 HURRICANE SHUTTERS p U- o0 o a <br />_ - m <br />DIM - DIMENSION SCP -SCUPPER <br />DISCON -DISCONNECT SCRN -SCREEN Q STAIRS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS U O <br />SH 1.4 HURRICANE SHUTTERS `- N V w QN N <br />DW - DISHWASHER SIM - SIMILAR LM o E <br />DR -DOOR SHLVS - SHELVES Q <br />CHIMNEY & FIREPLACE SH 1.5 HURRICANE SHUTTERS i., O 0 <br />DBL - DOUBLE S/R - SHELF & ROD CHAP. 10 WP1.0 WATERPROOFING DETAILS G� <br />DWG - DRAWING SH - SINGLE HUNG WINDOW <br />EA -EACH SGD - SLIDING GLASS DOOR Q EGRESS WINDOWS "z i <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV -ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS <br />EQUP - EQUIPMENT STD -STANDARD STATED BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS <br />EXP JT - EXPANSION JOINT STL -STEEL AND O.H. GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE <br />EXT - EXTERIOR STRUCT -STRUCTURAL ITEMS. THE MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED SITE INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR CRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR - FLOOR TP - TOILET PAPER HOLDER <br />FLCUR -FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS w° w w w O o <br />FR DR - FRENCH DOOR VAC -VACUUM W W W w p¢ Q 2 Q ¢ gd Y z w z <br />GALV -GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF � Q U_ ¢ a X _j � � � o `� " o o " � g <br />GB -GRAB BAR V FRT - VERIFY IAIN FIELD FLR TO BE TEMPERED GLASS. (SECTION R308) I- I- a w W o w W °za z J <br />GA -GAUGE° az,�LL_z20 �a <br />O O �WEL W°Wzw o� <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR EL <br />VTR - VENT THROUGH ROOF DIMENSIONING: z ¢ w ° g z g w v ° Q <br />GLS -GLASS V - VOLT LL ory o o a z a <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET A. DIMENSIONS INDICATED ARE TO: U_a p ~ ¢ U_GYPBRD - GYPSUM BOARD WH - WATER HEATER <br />HD - HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - - HEATING, VENTILATING, AIR CONDITIONING WP -WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF >f <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD O <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC - HANDICAP WDW - WINDOW <br />INSUL -INSULATION W/ -WITH FURRING\ N Z <br />A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD LU <br />INT - INTERIOR WD - WOOD A.4. WINDOW OPENINGS: i- <br />LVL - LAMINATED VENEER LUMBER A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING U)LT - LAUNDRY TUB _ ti <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING 5; (n O <br />MAX -MAXIMUM A.5. DOOR OPENINGS: Q F_ `CM O <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING Q J LO <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED IL 11' <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR U) [,,- <br />MC -MEDICINE CABINET FRAME Q W Q <br />MIN - MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER ~ of 0- M <br />OF DOOR 0-00 <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES -AS INDICATED ON PLANS OR FINISH z 0 Q <br />SURFACE TO FINISH SURFACE z V ~ <br />SYMBOL LEGEND. R SHOWER W z <br />B. ALIGNMENT OF WAL S AND FINIINSISHES AS SCHHE DE FINISH FOR UDLED SHALL BE E STRAIGHT, TRUE AND W CD <br />J CD <br />STAIR CALL OUT HEIGHT OF SHEET NUMBER PLUMB. O <br />STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: (01 <br />INT ELEV NUMBER C.I. CODE MINIMUM -MAXIMUM DIMENSIONS AND CLEARANCES <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />O = SEE FOOTING SCHEDULE CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />1 <br />ELEVV NUMBER UNLESS OTHERWISE NOTED <br />A9 ARROW SHOWS E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT <br />�q = OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />SCHEDULE ELEVATION MARKER Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE I I <br />1 < ELEV NUMBER SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LG-2 LEDGER CALL OUT -SEE SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 A15 2 LOCATION OF CUT COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />� 1 1 1 <br />3 % ARROW SHOWS DRAWINGS. <br />DIRECTION OF VIEW <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER 0 o No 0 0 Cq <br />0 <br />N NCD O <br />N <br />CD <br />o N 1 <br />P 1 <br />CD r r CD CD 1 1 <br />z <br />O <br />MAR 2 5 2023 W0 1 1 <br />N Lo / 01 <br />1 1 <br />/ � � N M d' In i i <br />' 0_ <br />0V (/) }~ <br />z z <br />aW <br />Virtual Review Assist, Inc. O -� zU5 <br />Plans Review completed and approved 0 U Woo <br />for compliance with the 2020 FBC 7th Edition Z)z� E N NARMWby Debra Anne Klahr PX2300 owp <br />EC�IVIt Q z a�a <br />L E N N A R TA M PA DIVISION ;APR 0 4 2023; = m� W <br />N 0 <br />460 W CYPRESS ST SUITE 200 z <br />Q NOTICE TO BUILDER & ALL SUBCONTRS W <br />TAMPA, FL 33607 �■- o Q ° azw <br />Q IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE z zz <br />13.574.5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING Qg <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT V _3HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O 0 0- <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE �MM <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE W <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE z <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z w <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION C J <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE LIJ N o <br />2216 INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE 0 -- p <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK LAST PLOT DATE <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE ' ' - <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND z 0 <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />J COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.