Laserfiche WebLink
248°° CE'I1AENT <br />PLASTER -- — - <br />h1 <br />12 1 DRYL,.OK <br />C t,41J - MAS NRY BILOC K <br />EXTREME <br />WINDOW <br />FASTENER <br />' 1 i SEALAt`T AT <br />d) SEALANT JOINT <br />+ <br />WINDOW DUCK TO <br />OUTSIDE EDGE OF <br />- MASONRY <br />WINDOW BUCK— <br />_2, SEALANT JOINT <br />a) SEALANT I rII,1Iup w <br />w o INSIDE EDGE OF <br />WIND W I i iilr. <br />�+ .� ', ". r' 1I'VINDOwISIc,i,.,K <br />Ai. ii I r ; vrllllilll,li.roilMi BI,I('K <br />. <br />AND k.°.,,,X71END I0 <br />/ —WINDOWI RAME <br />iJ'IA+SONIRY'--..__... <br />_ <br />`' T <br />A. TA(FiIED <br />N <br />PER CODE <br />6) TOOLED SEALANT <br />"' REQUIREI <br />BEAD BRIDGING <br />` <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WI1�� _'� FRAME T( <br />WINDOW BUCK ALL . HE WAY <br />AROUND„ INCLUI INQ SILL. <br />SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAL] DETAIL <br />APPROVED SHEATHING <br />APPROVED'H(DUSEWRAP <br />STRUCTALAtH TWiN TRACK 2.5 <br />314' CLEMENT PIASTER <br />12 MIL (min) DRYLOK F_XTRFME <br />APPROVED PLASHING _ TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />;. is Ii k� �� r -.-, ► -■ <br />WEATHER <br />RESiSITIVE <br />BARRIER <br />ram, r WEATHER <br />F'E BARRIER & <br />tARILY SECURE <br />WOOD FRAME CONSTR, <br />EXTERIOR SELF -ADHERED FI ASFOI+ <br />SHEATHING BY LIIIPPIIfdCF DOWN <br />OVER RII1A 1O[ST AND UP <br />., <br />WALL �.� � I, IN. <br />'FEATHER <br />RESISMVE <br />RARn R sFAI. TOP-5 OF J015TS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING , <br />HEAD FLASHING TIE-IN INSTRU''XTIONS: <br />1. Cut„ fold up & temporarily secure weather � <br />ril barrier above header to allkowr for <br />fhvstiing In tailatro s <br />2 O <br />��. Self-ridhc,ra,(.l flastlirlt� plus iniwar"f flasher . � 1under b <br />weather resistive stive arrio!r° 3, Fold weather resiharrier bark over head <br />flashing acidsealWith tape <br />SELF -ADHERED FLASHING Scale: NTS j j�'j <br />FLANGED WINDOWl '.J 1 <br />FLASHING INSTALLATION AFTER WEATHER PES.CTIVE FARRIERW W <br />S <br />DO NO' <br />80110 <br />Fi_AAdG <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Defer to the number r1llarlred as l" ? in each detail that corresponds to the <br />numDel items [it the list of Instructions below: <br />1, Install self-adl"iered flashing in order as shown by numbers <br />2. Install flashing ,and weather resistive barrier to form water shedding <br />laps <br />Sel 3. f=adhered flashing can be substituted for building paper <br />4. Split the release paper using the r ipcord (Split release on demand, <br />embedded in the adhesive layerj _ for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation Instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Min rnurn) <br />6, Fold as shown by arrows <br />T, Angle of coiner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8, Mechanically fasten as necessary <br />1 <br />r�nanF,v�.a <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2'.x FRAMEVVI!LL <br />TILE FINISH "- <br />1t2" DUROCK— <br />a,I;HIN I <br />AM <br />W P07 <br />A&ATHER R _SIS T IVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WiTH DECK - SECTION A <br />BEAD Of C'ON'STR= <br />IAI.)I1I SIA1i: TO III .' A,i- PL,IL:C <br />I HR&" SH( -D LgyT�I DOOR 0LII'�',II'1Iti B I„. US12L LIQU[D P <br />! R EQUAL WEATHER PR( <br />(SEE SLR,, <br />j ,JaEF I.7L 1AGC. FiI <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAH.1AIPl?"7) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />81° CM0 _ <br />4" OR 8" CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT ._ <br />ELOPED MUD RED...,.,..,,1,I <br />VINYL SHOWER PAN <br />a°. <br />_ <br />_... �_ <br />- <br />.,. Li <br />-- <br />d <br />,TM <br />- •g <br />--- '° ° <br />4 <br />w <br />49 <br />- --- - <br />, <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />iZ a- <br />Lu <br />C) <br />Lu <br />UJI <br />L!J <br />a <br />cq <br />WP11 <br /><< WINDOW INIT FLASHING REQUIREMENTS <br />DOOR ROUGH OPENING - <br />SLOPE <br />0.3 in : 12 0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />614%1" BEAD (DIF CONS .i (0. 6 cm : 30.5 CITE) include flashing as described in Section R7034. <br />ADHESIVE DD BE APPLIF [ 1 I„II°X)r:fq ...... SELF-ADHERFD FLASHING <br />I1R',=SI-IOU) <br />i <br />1 exterior I manner h ri1 I r RETURN ��, ���- .�°,��ixB � ,��,� � i1,II;I{, _ R703. I. � star rlsistance. The _ to wall envelope shall be designed and constructed in a that prevents the accu a dti Ji"i of water <br />NAI>Bi,AI..Ie" k I. 1i1L;Ps EXTERIOR <br />,� ,,.- ---. within the wall assembly by providing a watei -resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />PR OF C -AWLK - - CEMT. FIN„ <br />SE; F ADHERE a FLASH111,iG <br />BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. <br />WiRE LATH R70.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and Freaks, complying with ASTIR D2 C for Type 1 felt or other <br />-- <br />suBrLe i-7777 <br />°----;-� approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No 1 asphalt felt shall be applied horizontally <br />ply e pP p pp y <br />S c� PLASTER STOP <br />CONTINUOUS <br />ROD & SEALANT <br />k <br />with the upper layer lapped over the Tower layer not less than 2 inches. Where joints occur; felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />p p <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and term!ina'ted at penetrations and building <br />T <br />p� appendages il' a marlrlel° to meet the requi <br />FlIM J0[rements of the exterior all envelope as described in Section R703,1. <br />_ y <br />I R 0�_ star resistive barriers Water resistive barriers shall be Installed as required in Section R703.2 and, where applied over Wood based <br />_ t <br />sheatl�I,rig, shall Include a water resistive vapor permeable tea:=nor With a performance at leas_ equivalent to two, layers of Grade D paper. The <br />I, <br />2 c individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />~F accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />CENT. FIIfI H SILLI' F'OTSHELFi CHIMNEY SI-iOiJLDER Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />WP WP <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stuccoby an intervening, <br />NIEC i�iJaNI� I LLY T A' i'II J IF I" L)BBERIPEi3 <br />RUBBERIZEDASPHALT <br />P tT .-. substantially nor" water -absorbing layer or des,igne l drainage space, <br />IOEI'PL 1 IN <br />F_..,,•.YIf,Or,PPLR!Sl <br />AL)iIsiVE <br />"TAi S! I S [ III: I,T.i��.E1_F �c,mm iLiylip„u 1aiFAL r A� <br />R103,E Flashing. Approved metal flashing, vinyl flashing, self -adhere <br />d membranes and mechanically attached flexible flastl,nshall be, aPp <br />l,lo,dASH, rN°,11, �I�.4�, e_, � ^ <br />,_ g COL �.HEREGSASH shingI -ashron or In accordance with the manufacturer's instructions. Metal flashingshall be corrosion resistant, FIuId-appled membranes <br />ANGED i <br />used as flashing shall be applied _n accordance with the manufacturers Instructions. All flashing shall be applied In a manner to prevent the <br />e l SCORED entry of water into the wall cavity or penetration of water to the building structural framing components, <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall com I with AAl-AA 711, All exterior fenestration products shall be sealed at the juncture with <br />- - g py' - - - - p - <br />r LOESCORE <br />�,r,FvSE the building wall with a sealant complying with AAMA 800 or ASTM CO20 Class 25 Grade NS or greater for proper joint expansion and <br />_EN"M A °�' a_A RAPEP T� ADtIESWE a contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />1I FP010 <br />3TTCINAOF flashing in exterior wails shall comply with AAMA 714. The flashing shall extend to, the surface of the exterior wall finish. Approved fleshings <br />APE HO.F <br />shall be installed at the following locations: <br />f ", Il <br />1.1,Exterior windrow and door openings. Plashing at exterior window and door openings shall extend to the surface of the exterior wail) <br />. Faish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />1--x 1 _ ow a 11 i shall comply with AAMA . 2 Flashing at exterior find _ and door openings shall be installed in accordance' with one or more of the <br />�2 <br />I following: <br />5 1 A The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the dashing manufacturer's instructions. Where flashing instructions or details are <br />''` not provided, pals flashing g shall be installed at the sill cif exterior windowand docr openings. Pan flashing shall l sealed of <br />sloped in such a manner as to dlrect water to the surface of the exterior wall finish or to the outer resistive barrier for subsequent <br />° Ste` ) drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2.. In accordance withi the flashing design or lmethod of a registered design professional. <br />l 3 1,3, In iaccordaltice With other approved rnetho'd's. <br />WP05F- IHERED FLASHING �Et- AD <br />n r' I° FN . E 4 <br />INSIDE CORNER "'06 <br />Wt1J <br />1.1 l _accordance with FlvttA AAIA 10D, l=ltA AAIOA 20t1, F ArWDMA 250, Fl1AAiAA�1 WDMA 300 or 9AlAAIIA�WDMA 00" <br />2. 2,At the intersection of chimneys or, other, masonry construction with frame or stucco walls, with projecting lips on both sides under <br />- - - stucco copings. <br />l —: round - - 3.Under and at the ends of masonry, wood or metal copings and sills. <br />l i , 4,Continuously above all projecting wood trim. <br />t= 5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />_- 6,At wall and roof intersections- <br />Vvptp4 ResisIrint Farrier 7, 7.At built-in Clutters. <br />LF-AOHERED FLA,W,FTING <br />TCH <br />HERED FLASHING <br />12.,�1 <br />( <br />WP08 <br />I kIIIf OF Sa^ F <br />........4 yr{ARl AGE #-ALPI,F_ 4NI•t[YS <br />,,)ND BREAK 1 1Z <br />e <br />-SF LATH <br />} <br />,, <br />1 IRFAC:L T`,'Y.1F <br />AS loll AdR <br />,y <br />la <br />THIS GAP IS A RESULT OF <br />„ NATURAL SHRINKAGE <br />f iD nl(A SEAL <br />u u II 111 i o I°.,L , 11: <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />sluc(m <br />LEGEND <br />SELF ADHERED FL.ASH Nc (SAF;I <br />DRA9i�t���F PLANE DP WEATHER IRENST+ANT <br />BARRIER fA <br />€ CND BREAK WEA1 HER RESISTANT BARRIER - <br />SELF F R f - TI-I <br />PLASTER- ACCESSORY <br />OR - <br />SI EAT1 HIN O=SB•, PLNWOOD, DENSGLASs !� � <br />STRU' TURAL FRAMING <br />� STr� r � �r�,�,L SNSP,TFifPif <br />STRIP : �1 SAF <br />__- -Y� -D A.IIIaGE PlI WRB <br />BOND,fREAS �NRI-s <br />��[, � i f •,,� SSE LAI'i-I <br />ER STOP— <br />A <br />Ni_I t RAC:l I ti _ <br />AN IL <br />TIIIIOLA" FINISH <br />Cement Plaster <br />in accordance <br />With ASTMC926 <br />over woad 2nd <br />floor <br />• <br />! IlrfIN <br />i <br />- 7/8" Cement plaster <br />in accordance with <br />AS -I MC926 <br />Felt backed metal <br />lathe in accordance <br />With ASTMiC=1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weea Screed <br />Installed As Per <br />Matullact. Specs. <br />Maintain <br />Botto n of <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />rt <br />r <br />� <br />40 <br />IE <br />• <br />� <br />•' <br />4 <br />�► <br />« <br />•40 <br />0 <br />! <br />4 <br />- <br />i <br />411110 <br />• <br />40 <br />IF' <br />i <br />irtual Revi <br />Plans <br />ew assist, In <br />eview completed and a <br />. <br />P <br />b <br />nce with the 2020 FBC <br />Debra Anne Klahr <br />proved <br />th Edition <br />718" Cement Plaster <br />PX23 <br />in accordance with <br />A~STMC926 <br />Felt bricked metal <br />lathe in accordance <br />With ASTMC'l063 <br />ItI1Idlrtg Paper <br />7l16" O.V.B. <br />sheathing <br />Stampede orsimilar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />112" Cementitious <br />Decorative Finish <br />All inside ,and <br />outside corner willl <br />need to be Ii niter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />t <br />it <br />>li i <br />» <br />iV il; [:, of •m,'6i ie;ridlii li,'Udtl ,ci_;<I,i nlla�il: <br />