SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR EELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017, <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />MAR 0 4 2023 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 F0C 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH — <br />14 <br />DOORJAMB <br />DUPLEX <br />OUTLET <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />lip 110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—a DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />-6- CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />{} <br />SURFACE MNT FIXTURE <br />-- <br />WALL MNT FIXTURE <br />NOTE: <br />3 <br />OPALEX - <br />ALTERNATE <br />TUB/SHOWERND <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />O 50W MR16 4" LOW VOLTAGE OWNER <br />C 90W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />sj SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:FF 24" VANITY LIGHTING <br />FF—= 36 :F;� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />EM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />_ffi&3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />OB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />q: <br />^Vi <br />^^ll <br />0 LO E <br />0 <br />C'0 <br />0 <br />C) M i d <br />-0 7C) M <br />AU,, <br />W j 0 0 <br />2 <br />0 0 <br />o �o o Q <br />•0^` <br />i U�° } <br />w QN <br />7W <br />V <br />U <br />L p E <br />0 co <br />LLILLI <br />w <br />oUJ w w,0 <br />�LL00 <br />Q Q~ <br />V <br />=�03: <br />Q <br />oz�oL.LJz7�0<LL0U)m¢z <br />~�O� <br />DO UwW��-1 <br />0�zO <br />W <br />ZLUL— <br />Q¢LzuQIL <br />ELL <br />O <br />QO0 D Q= <br />0 <br />wa w <br />t <br />O <br />O <br />Z N <br />Off_ <br />U- ti <br />z <br />p c0 <br />Q w CO � <br />LL <br />coz < W < U� <br />Z U <br />W <br />W <br />J O <br />O <br />J <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />O <br />N <br />N <br />N <br />N <br />N <br />o <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />C <br />O <br />N <br />N <br />O <br />z <br />O <br />O <br />� <br />O <br />O <br />O <br />W <br />N <br />> <br />o <br />0 <br />0 <br />0 <br />oLO <br />I <br />r/� <br />zZ <br />v, <br />Q Z <br />w <br />O <br />W <br />000 <br />O <br />U <br />v(.)(/) <br />Lo-0 <br />O <br />Q III <br />ZUj <br />a�a <br />= <br />w=~ <br />m�� <br />Ln <br />0 <br />~p~O <br />N <br />�O� <br />W <br />W <br />z�Z) <br />. <br />Q <br />O <br />WW <br />O <br />gZO <br />LL <br />Z <br />az <br />(1)z <br />� <br />Z <br />�� <br />O <br />UO <br />W <br />zA602z <br />z <br />z <br />w <br />Uj <br />J <br />0 <br />0 <br />LAST PLOT DATE <br />December 1, 2022 <br />ZO <br />� <br />2ND FLOOR <br />ELECTRICAL PLAN <br />