My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36544 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36544 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:53:55 PM
Creation date
2/19/2025 9:11:39 AM
Metadata
Fields
Template:
Building Plans
Street #
36544
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5570
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DICONNECT <br />WP <br />GFI <br />ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /411 = 1'-0„ <br />POWER CO. FEED <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES - <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />- 210 or 4/0 SER Alu <br />-- 4 Bare Cu Ground <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />OCT 2 8 2022 <br />A <br />Virtual Review Assist, Ir c. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edit! <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH---.—\7 <br />�S <br />SWITCH- <br />4 1/2" <br />DOOR JAMB— <br />DUPLEX <br />OUTLET c> <br />TRIM-= <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL— - <br />o Z <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />AT 12" - TOP PLUG IS HOT <br />HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />&- SWITCH AT 36" <br />Cl) 3 WAY SWITCH AT 36" <br />-64!- 4 WAY SWITCH AT 36" <br />_0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />- fl DIMMER SWITCH AT 36" <br />-Lp PUSH-BUTTON DOORBELL <br />{A} CLG MNT LT FIXTURE <br />�-} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-}- WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />C TUB/SHOWER CANS MAY BE <br />C` 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />6l 50W MR16 4" LOW VOLTAGE OWNER <br />�(8�50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosSMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18= <br />UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />c S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9--24;;A 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />L 150W PAR 38 FL <br />0 INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />0 CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />if MASTER STATION <br />ELEC PANEL <br />0 VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />C] A/C REGISTER <br />OTT` THERMOSTAT <br />GB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />I: <br />w <br />W L /^i -0°? O <br />J CO N N <br />(N V -0-0 d (, <br />E . _ 2 Cl) <br />-0 S <br />i U}< <br />•N V LU QN C <br />7W 6-000 <br />-V E <br />0 11 a <br />C)LLl Uj W0 <br />W rW� �2� 0 ¢<zzW <br />�Q�WCrO¢0Q00_0x0 <br />Q V DOJ ILL p� JOQZu.z2_jF- �< <br />aW�OzOwO°mz0wzzLL '(1) W Lu n� Q0J <br />_1WQ�WOw0-OaQ0z� 0— <br />LL QOw Mt-F �w <br />OIr -0 :3o¢zOf <br />LL¢ O f Q LL <br />O <br />O <br />Z CNI <br />OF_ <br />(D =) ti <br />ID F_� (M O <br />Q w (M � <br />W z W LL <br />z < W Lq <br />F— W IcL M <br />CLQ�T- <br />Q°° <br />z F- <br />Z <br />W Wo <br />J O <br />(O <br />J <br />I I <br />I I I <br />Q0 <br />C) CD C) <br />O <br />N O C) <br />N N N <br />� M � <br />O �_ N <br />I i i I <br />z <br />O <br />N <br />0' <br />L00 0 0 <br />, <br />Ll > r- cv ch I I I = <br />LO <br />CO <br />(� Z <br />�/V Z H <br />z <br />C)`( w <br />z <br />W W O O <br />U <br />F- z)zj <br />ow0 <br />O or <br />Z a a� <br />Q O F- W <br />(� MW <br />Ln H~ <br />F- <br />O <br />O Z= <br />. . Or) Q O ZWO <br />0 U w u_ <br />Z ait <br />�Z <br />�C Q F� <br />OU J <br />_0 a. <br />W <br />Z A6 Z <br />z <br />w <br />W C4 <br />0 <br />N <br />C) <br />> . . LAST PLOT DATE O <br />August 8, 2022 <br />Z0 <br />O <br />_I ELECTRICAL PLAN <br />UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />c S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9--24;;A 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />L 150W PAR 38 FL <br />0 INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />0 CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />if MASTER STATION <br />ELEC PANEL <br />0 VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />C] A/C REGISTER <br />OTT` THERMOSTAT <br />GB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />I: <br />w <br />W L /^i -0°? O <br />J CO N N <br />(N V -0-0 d (, <br />E . _ 2 Cl) <br />-0 S <br />i U}< <br />•N V LU QN C <br />7W 6-000 <br />-V E <br />0 11 a <br />C)LLl Uj W0 <br />W rW� �2� 0 ¢<zzW <br />�Q�WCrO¢0Q00_0x0 <br />Q V DOJ ILL p� JOQZu.z2_jF- �< <br />aW�OzOwO°mz0wzzLL '(1) W Lu n� Q0J <br />_1WQ�WOw0-OaQ0z� 0— <br />LL QOw Mt-F �w <br />OIr -0 :3o¢zOf <br />LL¢ O f Q LL <br />O <br />O <br />Z CNI <br />OF_ <br />(D =) ti <br />ID F_� (M O <br />Q w (M � <br />W z W LL <br />z < W Lq <br />F— W IcL M <br />CLQ�T- <br />Q°° <br />z F- <br />Z <br />W Wo <br />J O <br />(O <br />J <br />I I <br />I I I <br />Q0 <br />C) CD C) <br />O <br />N O C) <br />N N N <br />� M � <br />O �_ N <br />I i i I <br />z <br />O <br />N <br />0' <br />L00 0 0 <br />, <br />Ll > r- cv ch I I I = <br />LO <br />CO <br />(� Z <br />�/V Z H <br />z <br />C)`( w <br />z <br />W W O O <br />U <br />F- z)zj <br />ow0 <br />O or <br />Z a a� <br />Q O F- W <br />(� MW <br />Ln H~ <br />F- <br />O <br />O Z= <br />. . Or) Q O ZWO <br />0 U w u_ <br />Z ait <br />�Z <br />�C Q F� <br />OU J <br />_0 a. <br />W <br />Z A6 Z <br />z <br />w <br />W C4 <br />0 <br />N <br />C) <br />> . . LAST PLOT DATE O <br />August 8, 2022 <br />Z0 <br />O <br />_I ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.