My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36576 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36576 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:29:06 AM
Creation date
2/19/2025 9:13:40 AM
Metadata
Fields
Template:
Building Plans
Street #
36576
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />N <br />to <br />to <br />Cn <br />0 <br />0 <br />0 <br />J <br />N <br />00 <br />I <br />N <br />U-) <br />E <br />0 <br />4 <br />0 <br />O <br />J <br />N <br />0 <br />I <br />N <br />L0 <br />L0 <br />0 <br />tT <br />0 <br />tT <br />i <br />kU— <br />Q <br />N <br />0 <br />rL <br />tJ <br />E <br />E <br />0 <br />v <br />ti <br />U <br />v <br />a <br />i <br />U <br />a� <br />0 <br />d <br />i <br />a <br />i✓ <br />0 <br />0 <br />J <br />a� <br />t� <br />N <br />O <br />0 <br />00 <br />45 <br />0 <br />0 <br />CV <br />CV <br />N <br />0 <br />c <br />co <br />45 <br />a <br />m <br />cn <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />M <br />C <br />20C <br />15C <br />UNDERGROUND IlDis <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 5 <br />GENERAL ELECTRICAL NOTES: I Typical 150-200 Amp <br />NOTE: ELECTRICAL MATERIAL AND <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UT <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />KD. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />O <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />�al <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PI3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�-6;2 <br />C. J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />AC PAD <br />150A1200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />NEMA 1 0 #12 to appliances and GFI <br />50 <br />20AMP/ 10 #10 to WH <br />10 #S to Range <br />10 #6 to HVAC <br />I I I <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />t'V <br />C-J <br />00 <br />cV <br />i� <br />w •� <br />O W <br />0 <br />a� o <br />t4�CVI> <br />�' <br />N Ct7 C1 a- <br />- •. <br />N b CO <br />E s <br />w_v «_ c <br />io <br />y w s� <br />� u w <br />N C. <br />C E <br />t0 p <br />d. U <br />CV <br />CV <br />O <br />CV <br />O <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential <br />7th Edition. Engineer's signature and seal <br />is only for <br />the structural <br />engineering portions of the drawing pages <br />bearing <br />Engineer's <br />signature and seal. <br />N <br />WAM A11111111111111, <br />a <br />vE <br />o 8 <br />O <br />WN <br />N C 0 <br />N O = 0 O <br />00 a) � <br />5toao No m <br />cnr� <br />Q <br />N J <br />C � <br />W <br />J fi-' t= d <br />a <br />(6 C CA <br />0 <br />rMo <br />W <br />_7 '@ o <br />W c6 m <br />LW <br />NLILZ <br />co N Z Q J <br />Z <br />N O U <br />3 <br />< <br />W <br />❑ El <br />M cN- <br />z N a <br />z � N <br />z � � <br />o <br />J <br />M <br />V) <br />^, <br />C a_ <br />W <br />_ 0 <br />cn <br />w <br />U <br />0 <br />V N <br />a y a <br />w!a <br />(� <br />r cn <br />U <br />w �a <br />a� <br />U o y <br />0-- <br />< o <br />o <br />N 01 <br />� <br />oja <br />J <br />w <br />Cy-, <br />M <br />p <br />z <br />Z <br />Z <br />< <br />J <br />Ll... C <br />z o <br />> N <br />¢ N <br />Q C <br />O <br />0 <br />uJ <br />Z <br />�< <br />00 <br />O� <br />o E <br />N ru <br />ao <br />wo <br />Z <br />wZ <br />o <br />L <br /><p <br />m <br />[y <br />_ <br />Y <br />O <br />0 <br />Z <br />J <br />Uo <br />i�� <br />¢w <br />ern <br />U) <br />a��i <br />< <br />8< <br />Z <br />go <br />Q <br />ww <br />aZ rn w <br />oz <br />�3 <br />o <br />o <br />CLJ <br />=a <br />Eo <br />a s <br />� <br />z¢ <br />U� <br />NT <br />>LO <br />J <br />rn <br />m <br />Q <br />c� <br />C <br />0 <br />O <br />C:) <br />_l <br />r <br />Y <br />m <br />U) m <br />N <br />LO <br />c <br />-0 N <br />O <br />co <br />-0co <br />M <br />o <br />In <br />M <br />Q <br />LO <br />r <br />E(.0 <br />00 <br />c <br />o <br />z <br />E C) <br />a <br />ca <br />m0 <br />d <br />E <br />U -j <br />-0 <br />Q p <br />_ <br />J <br />JOB <br />NO: <br />22-09412 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.