Laserfiche WebLink
ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0„ <br />1 IAIC /lC onnr <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED 'rO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 210 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to looter steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Ed7i <br />by Debra Anne Klahr PX2300 <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />Ilk <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ_ <br />k <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />sw STRUCTURED WIRE OUTLET <br />6- SWITCH AT 36" <br />Cl) 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--0 DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />£A� CLG MNT LT FIXTURE <br />}B CLG MNT PREWIRE - FIXTURE BY OWNER <br />C SURFACE MNT FIXTURE <br />{ WALL MNT FIXTURE <br />NOTE: <br />Q ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />4� O 50W PAR30 NFL 6WHITE BAFFLE USED IF <br />" APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />-S-24= SINGLE 24" FLUOR STRIP <br />-D-24- DOUBLE 24" FLUOR STRIP <br />U-36 UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 -� 48"CLG MNT WRAPPED FLUOR LIGHT <br />5_� 24 ­9 24" VANITY LIGHTING <br />gr�u,_ 36 :;� 36" VANITY LIGHTING <br />48� 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />® A/C REGISTER <br />OT THERMOSTAT <br />TR SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />a: <br />nN` O LO E <br />0 0 <br />W L <br />0 My Gi <br />M ry <br />j' <br />0 v -070 4 <br />0 <br />o o <br />2 <br />O �o N Q <br />•/I�` W Q� h <br />L MO E� <br />W 5 <br />70 C) r, O� m <br />W(� <br />WO�2 <br />W <br />f-Q o-' W§ zW <br />0' z <br />Qp�wLL00_j0 <br />U <br />I­_uW90OomZz <br />_�EoQ cy) <br />aa <br />ci <br />Cy <br />(A 0 <br />Z <br />_LL, WO�ya z0z 0 <br />I�< W<F_WWLL <br />o���¢ <br />00r o : pQz9< <br />o a,L <br />,L¢ <br />O <br />Z <br />LU <br />O� <br />W ti <br />0I--.MO <br />M <br />Q U) � <br />U) LL ti <br />z <br />Ln <br />E— W M <br />co <br />< <br />< <br />Z U F— <br />Z <br />LU <br />Wo <br />J O <br />mi <br />N <br />N <br />O <br />N <br />N <br />i <br />O <br />O <br />Oo <br />(O <br />00 <br />0 <br />0 <br />0 <br />C)O <br />O <br />N <br />CDO <br />N <br />N <br />C) <br />N <br />CD <br />N <br />C:)N <br />N <br />00 <br />O <br />In <br />r- <br />00 <br />O <br />M <br />, <br />N <br />O <br />M <br />00N <br />C)C:) <br />d <br />,� <br />O <br />O <br />C:) <br />O <br />O <br />r <br />0 <br />O <br />0 <br />' <br />O <br />0 <br />N <br />> <br />0 <br />0 <br />N: <br />0 <br />M <br />0 <br />"T <br />0 <br />L7 <br />0 <br />(0 <br />0 <br />I-- <br />LO <br />I <br />1 <br />Cr <br />CO <br />V) <br />z z <br />—_ <br />zO <br />C)}, <br />W <br />W I— C) I__ <br />�.� <br />O <br />U0 <br />I— <br />� < <br />O a. <br />V) <br />Zw�Q <br />re <br />Q <br />Z� <br />Q <br />r <br />m O Z <br />=z <br />r=nl- <br />V <br />O <br />N <br />> J z <br />00 <br />�2zW <br />M <br />�zzu_ <br />pp <br />w N <br />O�Mz <br />Q <br />UU)zz <br />z <br />EEQO <br />Z <br />U <br />U <br />� <br />O <br />O <br />W <br />w <br />Z <br />Q <br />z <br />z <br />w <br />J <br />N <br />N <br />W <br />LAST PLOT DATE <br />Co <br />Jul. 21, 22 <br />Z <br />0 <br />1 ST & 2ND FLOOR <br />� <br />J <br />ELECTRICAL PLAN <br />B <br />