My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37623-37643 Georgina Ter
Zephyrhills
>
Building Department
>
Building Plans
>
37623-37643 Georgina Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 11:50:56 AM
Creation date
2/19/2025 9:14:46 AM
Metadata
Fields
Template:
Building Plans
Street #
37623-37643
Location
Georgina Ter
Contractor
Lennar Homes LLC
Building Plans - Permit #
12439-12444
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" <br />AFF (general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance <br />with the national electric code, latest edition, by a licensed electrical contractor who shall be <br />responsible for the installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R313.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination tyke installed to provide protection <br />of the branch circuits in all dwelling units per NFPA 70 and the 2008 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2008 NEC, 406.11 <br />8. R313.2 1 carbon monoxide protection: carbon monoxide alarms or detectors shall be installed <br />in all dwelling units in accordance with NFPA 70. Such devices shall be listed by the <br />appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms <br />or UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R313.2.2 3 combination alarms: combination smoke/carbon monoxide alarms shall be <br />permitted if each meets the applicable UL standard. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source <br />and shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and <br />soffits is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped <br />with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 <br />DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a <br />continuous audible warning when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where <br />installed within 6' if the outside edge of a sink. This would include the receptacle installed for a <br />washing machine. Receptacles outlests shall not be required on a wall directly behind a range <br />or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to <br />be included in the spacing of the outlets unless the distance from the sink or range is greater <br />the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FqT <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />r- . <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />4- <br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />O; <br />RECESSED INCANDESCENT LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)C STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�]M ELECTRIC METER <br />ELECTRIC PANEL <br />—AM__j DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />if <br />C <br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ <br />C J ROUGH -IN FOR OPT. CEILING FAN <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />UNIT 1501 NIT 1399 NIT 1398 <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING AREAS, SHALL <br />BE INTERCONNECTED, SHALL BE WITHIN 1' TO 3' OF PEAK, AND <br />SHALL BE 3' FROM THE SUPPLY OR AIR STREAM, AND EQUIPPED <br />WITH BATTERY BACK-UP. ALL SMOKE DETECTORS TO BE <br />ARC -FAULT PROTECTED. <br />sYMUROL <br />ELECTRICAL PLAN <br />SCALE: 3/16"=1'-0" <br />to <br />L_ <br />O <br />M <br />0 <br />u <br />_ � <br />vi C <br />v O <br />M <br />H N <br />005 co')o <br />a a <br />ON <br />N <br />V) <br />ra <br />o"�00 <br />m l>S Ct U <br />� <br />� <br />�C: <br />c) w � <br />;E <br />MLLM m <br />OM-he <br />04 <br />U <br />t1 0 0 <br />' aro <br />'r <br />cn a � <br />rn � <br />6 <br />A 0 <br />It M. <br />NCB�vZ <br />'.. <br />O <br />Z W 7 <br />N <br />C <br />r Z <br />— in 1,t ` <br />LU <br />O J <br />Q <br />W a'LL� <br />O WCN <br />ZW <br />M <br />LL j5 U) ME <br />H Z <br />00 m m <br />Q <br />W o a <br />d <br />O J v <br />O <br />� <br />To the best of the engineers knowledge and <br />understanding, the structural plans and <br />specifications comply with the 2007 Florida <br />Building Code, Residential with 2009 revisions <br />signed and sealed for the structural portion of this <br />drawing. <br />it <br />O <br />N M <br />Z � M <br />r <br />0 � to <br />> N O <br />M O <br />0 N <br />Q z fu 'i <br />.al� <br />Z <br />� N <br />n <br />N <br />Z <br />LU <br />W <br />C <br />JLna) <br />L U <br />Q <br />Z <br />W <br />0 z <br />Woo <br />mz�i2� <br />�o <br />w <br />zQ� <br />� <br />M <br />Z <br />U Qf¢ <br />ZW~z <br />O <br />g La0 J <br />N <br />� <br />°ot-zN <br />a U O UD <br />�3uo <br />W <br />0 <br />O <br />U.1 <br />Z <br />�J <br />rA <br />%D <br />NO <br />Ln <br />Z <br />4t <br />LL <br />QO <br />W <br />wQ�03 <br />ce V S VY O C <br />12 O O <br />Q <br />90zm <br />0 <br />W <br />Z <br />J LLI <br />O 0 <br />Q <br />fM <br />I--1 J Q <br />5� <br />F- Lu <br />tQQ- <br />a <br />rat <br />Z W <br />QLU <br />U WaELLZ <br />paW� <br />`U 0 IL Z Q <br />I.n <br />DC <br />O <br />N <br />*� <br />I <br />�— <br />aWWa <br />IdW <br />a~� <br />z <br />o <br />V <br />" <br />> <br />F_ <br />g J <br />Z <br />O <br />a W <br />SCALE <br />AS NOTED <br />PLOT DATE : 08 / 17 / 2011 <br />VERSION NO. <br />1000 <br />JOB NO: 11-1198-1203 <br />SHEET NO. <br />8 <br />=s <br />min <br />
The URL can be used to link to this page
Your browser does not support the video tag.