13.3 erior windows, sliding and patio glass doors. <br />1 3.1 Testing and labeling. Exterior windows and glass doors shall be tested by an approved independent testing laboratory, and shall be labeled to <br />d cate compliance with the requirements of one of the following specifications: <br />I/AAMA/NWWDA101/I.S.2 or ANSI/AAMA/WDMA 101/I.S.2/NAFS or AAMA/WDMA/CSA 101/I.S.2/A440 or TAS 202 (HVHZ shall comply with TAS 202 utilizing ASTM E 1300-98 <br />ASTM E 1300-04 02). <br />erior windows and sliding glass doors shall be labeled with a permanent label, marking, or etching providing traceability to the manufacturer and product. <br />following shall also be required either on a permanent label or on a temporary supplemental label applied by the manufacturer: information identifying <br />manufacturer, the product model/series number, positive and negative design pressure rating, product maximum size, glazing thickness, impact -resistance <br />ing if applicable, Florida Product Approval number or Miami -Dade Product Approval number, applicable test standard(s), and approved product certification <br />ncy, testing laboratory, evaluation entity or Miami -Dade Product Approval. <br />labels are limited to one design pressure rating per reference standard. The temporary supplemental label shall remain on the window or door until final <br />roval by the building official. <br />eptions: <br />Door assemblies installed in nonhabitoble areas where the door assembly and area are designed to accept water infiltration need not be tested for water <br />iltration. <br />Door assemblies installed where the overhang (OH) ratio is equal to or more than 1 need not be tested for water infiltration. The overhang ratio shall be <br />culoted by the following equation: <br />ratio = OH length/OH height <br />re: <br />length = The horizontal measure of how for an overhang over a door projects out from door's surface. <br />height = The vertical measure of the distance from the door's sill to the bottom of the overhang over a door. <br />Pass -through windows for serving from a single-family kitchen, where protected by a roof overhang of 5 feet (1.5 m) or more shall be exempted from the <br />uirements of the water infiltration test. <br />Decorative glazed openings. <br />ass Strength: Products tested and labeled as conforming to ANSI/AAMA/NWWDA 101/I.S.2 or ANSI/AAMA/WDMA 101/I.S.2/NAFS or AAMA/WDMA/CSA 101/I.S.2/A440 or <br />202 shall not be subject to the requirements of the Florida Building Code, Building. Determination of load resistance of glass for specific loads of <br />ducts not tested and certified in accordance with Section R613.3.1 shall be designed and labeled to comply with ASTM E 1300. The temporary supplemental <br />el shall designate the type and thickness of glass or glazing material. <br />ss Strength: Products tested and labeled as conforming to ANSI/AAMA/NWWDA 101/I.S.2 or 101/I.S.2/NAFS or AAMA/WDMA/CSA 101/I.S.2/A440 or TAS 202 shall not <br />subject to the requirements of the Florida Building Code, Building. Determination of load resistance of glass for specific loads of products not tested <br />certified in accordance with Section R613.3.1 shall be designed and labeled to comply with ASTM E 1300. The supplemental label shall designate the type <br />thickness of glass or glazing material. <br />8.6.9 Testing and labeling of skylights. Exterior skylights shall be tested by an approved independent testing laboratory, and shall be labeled to <br />icate compliance with the requirements of one of the following specification: <br />I/AAMA/WDMA 101/I.S.2/NAFS or AAMA/WDMA/CSA 101/I.S.2/A440, or TAS 202 (HVHZ shall comply with TAS 202). <br />erior skylights shall be labeled with a permanent label, marking, or etching providing traceability to the manufacturer and product. The following shall <br />o be required either on a permanent label or on a temporary supplemental label applied by the manufacturer: Information identifying the manufacturer, the <br />duct model/series number, positive and negative design pressure rating, product maximum size, type and thickness of glass or glazing material, <br />act -resistance rating if applicable, Florida Product Approval number or Miami -Dade Product Approval number, applicable test standard(s), and approved <br />duct certification agency, testing laboratory, evaluation entity or Miami -Dade Product Approval. <br />els are limited to one design pressure rating per reference standard. The temporary supplemental label shall remain on the skylight until final approval <br />the building official. <br />3.3.2 Comparative Analysis Label. A temporary supplemental label conforming to AAMA 203, Procedural Guide for the Window Inspection and Notification <br />tem, shall be acceptable for establishing and communicating the calculated allowable design pressures higher than indicated on the label required by <br />tion R613.3.1 for window or door sizes smaller than that required by the ANSI/AAMA/NWWDA 101/I.S.2 or ANSI/AAMA/WDMA 101/I.S.2/NAFS or AAMA/WDMA/CSA <br />/I.S.2/A440 test requirements. This temporary supplemental label shall be applied by the manufacturer and remain on the window or door until final <br />roval by the building official. <br />eption 1: <br />arative analysis of operative windows and glazed doors may be made, provided the proposed unit complies with the following: <br />Shall always be compared with a tested and currently approved unit. <br />Varies only in width, height and/or load requirements. <br />Shall not exceed 100 percent of the proportional deflection for fiber stress of the intermediate members of the approved unit. <br />Shall conform as to extruded members, reinforcement and in all other ways with the tested approved unit. <br />Shall not exceed 100 percent of the concentrated load at the juncture of the intermediate members and the frame of the approved unit. <br />Shall not permit more air and water infiltration than the approved unit based on the height above grade. <br />Compared unit shall not exceed the maximum cyclic pressure when tested per TAS 203 or ASTM E 1886 and ASTM E 1996. <br />eption 2: <br />arative analysis of fixed glass windows may be made, provided the proposed unit complies with the following: <br />Shall always be compared with a tested and currently approved unit. <br />Varies only in width, height and/or load requirements. <br />The design is identical in all respects. e.g., extrusions, glazing system, joinery, fasteners, etc. <br />Shall not permit more air and water infiltration than the approved unit based on height above grade. <br />The maximum uniform load distribution (ULD) of any side is equal to the uniform load carried by the side divided by the length of the side. <br />The ULD of any member must not exceed the ULD of the corresponding member of the tested window. <br />The uniform load distribution on each member shall be calculated in accordance to Section 2, Engineering Design Rules, of the AAMA 103.3 Procedural <br />de. <br />Compared unit shall not exceed the maximum cyclic pressure when tested per TAS 203 or ASTM E 1886 and ASTM E 1996. <br />3.4 Exterior door assemblies. Exterior door assemblies not covered by Sections R613.3 or R613.4.3 shall comply with Sections R613.4.1 or R613.4.2. <br />3.4.1 Exterior door assemblies shall be tested for structural integrity in accordance with ASTM E 330 Procedure A at a load of 1.5 times the required <br />ign pressure load. The load shall be sustained for 10 seconds with no permanent deformation of any main frame or panel member in excess of 0.4 percent of <br />span after the load is removed. HVHZ shall comply with TAS 202. After each specified loading, there shall be no glass breakage, permanent damage to <br />tenersI hardware parts, or any other damage which causes the door to be inoperable. <br />minimum test sizes and minimum design pressures shall be as indicated in Table R613.4 <br />Uunit size tested shall qualify all units smaller In width and/or height of the some operation type and be limited to cases where frame, panels and <br />uctural members maintain the some profile as tested. <br />3.4.2 Sectional garage doors shall be tested for determination of structural performance under uniform static air pressure difference in accordance with <br />I/DASMA 108 or TAS 202 (HVHZ shall comply with TAS 202). <br />3.4.3 Custom doors. Custom (one of a kind) exterior door assemblies shall be tested by an approved testing laboratory or be engineered in accordance with <br />epted engineering practices. <br />3.4.4 Door components evaluated by an approved product evaluation entity, certification agency, testing laboratory or engineer may be interchangeable in <br />erior door assemblies provided that the door component( s) provide equal or greater structural performance as demonstrated by accepted engineering <br />ctices. <br />3.4.4.1 Optional exterior door component testing. With the exception of HVHZ, exterior side -hinged door assemblies not covered by Section R613.3 shall <br />e the option to have the components of the assembly tested and rated for structural integrity in accordance with the following specification: <br />A250. 13 <br />lowing the structural testing of exterior door components, there shall be no permanent deformation of any perimeter frame or panel member in excess of <br />percent of its span after the load is removed. After each specified loading, there shall be no glass breakage, permanent damage to fasteners, hardware <br />ts, or any other damage that causes the door to be inoperable, as applicable. <br />3.4.5 Garage door labeling. Garage doors shall be labeled with a permanent label provided by the manufacturer. The label shall identify the manufacturer, <br />garage door model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, the installation instruction <br />wing reference number, the Florida Product Approval or Miami -Dade Product Approval number if applicable, and the applicable test standards. <br />required garage door components for an approved garage door assembly may be indicated using a checklist format on the label. If a checklist format is <br />d on the label, the installer or manufacturer shall mark the selected components on the checklist that are required to assemble on approved garage door <br />tem. <br />installation instructions shall be provided and available on the job site. <br />3.5 Wind-borne debris protection. Protection of exterior windows, glass doors and other glazed areas shall be in accordance with Section R301.2.1.2. <br />3.5.1 Fenestration testing and labeling. Reserved. <br />3.6 Anchorage methods. <br />3.6.1 Anchoring requirements. Window and door assembly anchoring systems shall be tested to achieve the design pressure specified. Substitute anchoring <br />temps shall provide equal or greater anchoring performance as demonstrated by accepted engineering practice. When provided, the manufacturer's published <br />tallation instructions for as tested or substitute anchoring systems can be used. In no case shall the anchorage exceed the spacing for the tested rated <br />formance. <br />3.6.1.1 Masonry, concrete or other structural substrate. Where the wood shim or buck thickness is less than 11/2 inches (38 mm), window and door <br />emblies shall be anchored through the main frame or by jamb clip or subframe system, in accordance with the manufacturers published installation <br />tructions_ Anchors shall be securely fastened directly into the masonry, concrete or other structural substrate material. Unless otherwise tested, bucks <br />11 extend beyond the interior face of the window or door frame such that full support of the frame is provided. Shims shall be made from materials capable <br />sustaining applicable loads, located and applied in a thickness capable of sustaining applicable loads. Anchors shall be provided to transfer load from <br />window or door frame to the rough opening substrate. <br />re the wood buck thickness is 11/2 inches (38 mm) or greater, the buck shall be securely fastened to transfer load to the masonry, concrete or other <br />uctural substrate and the buck shall extend beyond the interior face of the window or door frame. Window and door assemblies shall be anchored through the <br />n frame or by jamb clip or subframe system or through the flange to the secured wood buck in accordance with the manufacturers published installation <br />tructions. Unless otherwise tested, bucks shall extend beyond the interior face of the window or door frame such that full support of the frame is <br />vided. Shims shall be made from materials capable of sustaining applicable loads, located and applied in a thickness capable of sustaining applicable <br />ds. Anchors shall be provided to transfer load from the window or door from assembly to the secured wood buck. <br />3.6.1.2 Wood or other approved framing material. Where the framing material is wood or other approved framing material, window and glass door assemblies <br />11 be anchored through the main frame or by jamb clip or subframe system or through the flange in accordance with the manufacturer's published <br />tallation instructions. Shims shall be made from materials capable of sustaining applicable loads, located and applied in a thickness capable of <br />toining applicable loads. Anchors shall be provided to transfer load from the window or door frame to the rough opening substrate. <br />3.7 Mullions occurring between individual window and glass door assemblies. <br />3.7.1 Mullions. Mullions, other than mullions which are an integral part of a window or glass door assembly tested and labeled in accordance with Section <br />3.3.1, shall be tested by an approved testing laboratory in accordance with AAMA 450 or be engineered in accordance with accepted engineering practice. <br />3.7.1.1 Engineered mullions. Mullions qualified by accepted engineering practice shall comply with the performance criteria in Sections R613.7.2, <br />3.7. 3, and R613. 7.4. <br />13.7.1.2 Mullions tested as stand alone units. Mullions tested as stand alone units in accordance with AAMA 450 shall comply with the performance criteria <br />Sections R613.7.2, R613.7.3, and R613.7.4. <br />3.7.1.3 Mullions tested in an assembly. Mullions qualified by a test of an entire assembly in accordance with AAMA 450 shall comply with Sections <br />3. 7. 2 and R613. 7. 4. <br />13.7.2 Load transfer. Mullions shall be designed to transfer the design pressure loads applied by the window and door assemblies to the rough opening <br />strate. <br />LE R613. 4 <br />IMUM TEST SIZES, INCLUDING FRAMING <br />formance Class* Width x Height (mm) Width x Height (in.) Minimum Performance Grade <br />sign Pressure) <br />identiol (R) 900 x 2000 (36 x 79) 720 Pa (15 psf) <br />ht Commercial (LC) 900 x 2100 (36 x 83) 1200 Pa (25 psf) <br />rcial (C) 1000 x 2100 (40 x 83) 1440 Po (30 psf) <br />vy Commercial (HC) 1200 x 2400 (48 x 95) 1920 Po (40 psf) <br />hitectural (AW) 1200 x 2400 (48 x 95) 1920 Pa (40 psf) <br />rformance Class and Performance Grade per ANSI/AAMA/NWWDA 101/I.S.2-97 <br />3.7.3 Deflection. Mullions shall be capable of resisting the design pressure loads applied by the window and door assemblies to be supported without <br />letting more than L/175, where L is the span of the mullion in inches. <br />3.7.4 Structural safety factor. Mullions shall be capable of resisting a load of 1.5 tines the design pressure loads applied by the window and door <br />emblies to be supported without exceeding the appropriate material stress levels. If tested by an approved laboratory, the 1.5 times the design pressure <br />d shall be sustained for 10 seconds, and the permanent deformation shall not exceed 0.4 percent of the mullion span after the 1.5 times design pressure <br />d is removed. <br />3.7.5 Installation instruction for exterior windows and doors. Windows and doors shall be installed in accordance with ASTM E 2112 or in accordance with <br />manufacturer's installation instruction. <br />3.8 Flashing, sealants and weatherstripping. Flashing and sealants for exterior windows and doors shall comply with Section R703.8. <br />3.8.1 All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 and ASTM C 920 <br />s 25 Grade NS or greater for proper joint expansion and contraction, ASTM C 1281, AAMA 812, or other approved standard as appropriate for the type of <br />a n t. <br />13. Masonry rough openings. Masonry rough opening dimensions shall be within the tolerances specified at Section R606.12 and in addition shall provide <br />r a win erimeter sealant 'oint a maximum of 1 4 inches in width. <br />2 "x12" BEAM <br />2x 6 P.T. WOOD JAMB <br />PLYWD SHEATHING AND SIDING <br />_F <br />of2 <br />f__ T <br />2x6 END STUD <br />2x6 END STUD <br />(CONVENTION CORNER) <br />1/4"x 3-1/2" WOOD SCREWS g 24" O.G. <br />CONT. WOOD TRIM <br />L DOOR AND CONNECTION PER <br />GARAGE DOOR MANUFACTURER <br />2x6 GYP_ SD_ SACKER <br />(PRE -INSULATE VOID)J \-PLYWD SHEATHING AND SIDING <br />BACKING FOR EXT. SIDING 4 TRIM <br />3 STUD COS NOR DOTAI <br />Frame Wa I I <br />SILL <br />H <br />UNIT DIMENSION <br />WIDTH <br />JAMB <br />�U UJINDOW <br />WINDOW 4 DOOR FASTENING <br />2020 Florida Building Code NOTES <br />L ALL EXTERIOR WINDOWS AND GLASS DOORS SHALL <br />BE TESTED IN ACCORDANCE WITH ANSIIAMMA/NIUllDA <br />10VIS2 STANDARD AND SEAR AN AMMA OR UVMA <br />LABEL INDICATING, ML41•YIFACTURERS PERFORIANCE AND <br />APPROVED PRODUCT TESTMG ENTITY, IN ACCORDANCE <br />WITH 2O20 Florida Building Code, SECTION 1101421 <br />2. ALL EXTERIOR DOORS AND WINDOWS, SHALL ISE <br />ANCHORED IN ACCORDANCE WITH MANIFACTIbZERS <br />SPECIFICATIONS, IN ACCORDANCE WITH 2O20 FLORIDA <br />BUILDING CODE r101.4.L <br />3. WINDOWS AND DOORS FASTENED TO BUCK STRIPS <br />LESS THAN 1 1/2" SHALL BE ANCHORED THROUGH <br />THE JAMS TO THE STRUCTURAL SUBSTRATE, IN <br />ACCORDANCE WITH 2O20 Florida Bullding Code. 1101442 <br />4. WINDOW AND DOOR MULLION ASSEMBLIES SHALL BE <br />DESICsTED AND TESTED TO TRANSFER IB TIMBS THE <br />INDICATED DESW4 LOADS, TO THE STRUCTURAL SUBSTRATE <br />IN ACCORDANCE WITH, 2020 Florida BulldWQ Code <br />T101ASJ AND r101454. <br />ATTACHMENT OF <br />WINDOW TO FRAME <br />WALL TO SE PER <br />MANUFACTURERS <br />RECOMMENDATION_ <br />b <br />d' <br />SHINGLES PER SPECIFICATIONS (W/ 6 FASTENERS <br />PER SHINGLE) FELT UNDERLAYMENT MUST BE 300 <br />OR EQUIVALENT (ASTM D 226 TYPE II, ASTM D4869 <br />OR PEEL AND STICK ROOF UNDERLAYMENT ON 1/2" <br />PLYWOOD OR OSB W/H-CLIPS ON 2x10's 6 24"O.C. <br />(FOR NAILING SCHEDULE SEE SHEET S2C) - SEE <br />ADDITIONAL INFO BELOW <br />PANEL EDGE SUPPORT FOR NARROW WIDTH ROOF <br />SHEATHING" PER TECHNICAL NOTE *R2-I5A 16-24 "-DOUBLE <br />PLY GLIP THE SIDE ADJACENT TO THE FULL WIDTH PANEL - <br />NONE REQUIRED AT RIDGE OR HIP. 12" TO 16" - LUMBER <br />ONLY BLOCKING (2x4) FLAT WISE OR ENDWISE ON THE SIDE <br />ADJACENT TO THE FULL WIDTH PANEL NONE REQUIRED AT <br />RIDGE OR HIP. FOR PLYWOOD SHEATHING 12" OR LESS - <br />LUMBER ONLY BLOCKING, (2x4) FLAT WISE OR EDGEWISE ON <br />BOTH PANEL EDGES. <br />12 <br />INSULATION 20 <br />UNLESS OTHERWISE NOTED - ALL THERMAL INSULATION <br />SHALL BE AS FOLLOWS: <br />CONC BLOCK WALLS R-3 BLOWN CELLULOSE OR R-4B <br />ALUMINUM MULTI SHEETS FOIL <br />FRAMED WALLS R-11 FIBERGLASS GATT <br />INTERIOR CEILINGS R-IS FIBERGLASS GATT OR BLOWN <br />CEILINGS UNDER ATTIC R-38 FIBERGLASS GATT OR BLOWN <br />SIMPSON H10A <br />PLT. HGT VINYL SOFFIT <br />ALL WIDT <br />-J <br />ALUM. DRIP EDGE <br />2X6 SUB FASCIA <br />FASCIA COVER INSTALLED IN <br />ACCORDANCE WITH FASCIA <br />MANUFACTURER'S PRODUCT <br />APPROVAL SPECIFICATION AND <br />LIMITATIONS OF USE <br />ATTACH SOFFIT <br />TO FASCIA OR <br />TO NAILING <br />STRIP (NOT <br />SHOWN) <br />2x16 RIM JOIST <br />EXTERIOR SIDING OVER <br />*15 BLDG. FELT WITH <br />OR WITHOUT INSULATIVE <br />FIBER BOARD 4 SHEATHING <br />FOR NAILING SEE SHEET 525 <br />TABLE 2304.9.1 FASTENING SCHEDULE <br />(1) 20'-0" *4 COPPER (WITH <br />APPROVED CLAMP) TIED <br />TO FTG_ STEEL AND GRND. <br />ROD (BY OTHERS) AT <br />ELECTRICAL BOX LOCATION <br />51MP50N TP31 <br />SIMPSON H10A <br />SIMPSON 18" FLAP STRAP <br />SIMPSON LSSU 210 <br />(2)2x12 RIDGE SEAM <br />SIMPSON TP31 <br />12 <br />9 <br />SIMPSON SP2 <br />(2)2x4 <br />SIMPSON 5P2 <br />2x6 COLLAR <br />1/2 "DRYWALL OVER <br />2X4 STUDS 9 Ito" O.C. <br />zO <br />S IMPSON 15P1 <br />(2)2X6 TOP PLATE 3/4" PLYWOOD W/ Sd NAILS tI <br />6" O.G. 10 EDGES AND 12" O.G. <br />J - CI-IANNEL INTERMEDIATE <br />- 2x6 BASE PLATE WOOD BASE <br />(2)2X6 TOP PLATE <br />2X6 BLOCKING <br />TIE MAX 1/2" GALV. ROD <br />ti -12" O.C. 4 EACH SIDE <br />OF OPENING <br />1611 FLOOR 6 i-STEM 42 e Ira" O_C: <br />1/2" CD OR 5/8" <br />DRYWALL ON CEILING <br />(2)2X4 or (2)2X6 <br />TOP PLATE <br />2X4 or 2X6 <br />JACKS <br />(2)2X6 *2 YELLOW <br />PINE HEADER (UP <br />TO 5'-0" SPAN) OR <br />(2) 2X12 Y.P. HDR <br />WINO JACKS) <br />UM. WINDOW <br />%RBLE SILL <br />:4 SILL PL. or 2X6 SILL OL. <br />2�4 PT <br />Z F <br />U <br />3000 n <br />Z fo"x 6"x 10/10 E.W.W. MESH REINFORCING o <br />° REQUIRED THROUGHOUT THE CONCRETE SLAB 0 <br />i_1 <br />ROD (BY OTHERS) 6 MIL. VAP. BARRIER �' <br />li-QII 0 <br />VCR (2)S REBAR CONT. ON *3 CHAIRS a) <br />(3" MIN. COVER) 0 <br />U) <br />CONCRETE -ENCASED ELECTRODE_ AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WITHIN <br />AND NEAR THE BOTTOM OF THE CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE E <br />EARTH, CONSISTING OF AT LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICITY O <br />p CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH DIAMETER, OR U <br />CONSISTING OF AT LEAST 20 FEET OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4 AWG. REINFORCING <br />BARS SHALL BE PERMITTED TO BE BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER EFFECTIVE N <br />J MEANS_" N <br />2' 4' 1 oYfo. wAiim rCmr IO1�l <br />S2A 0 <br />O <br />14 I WINDOW /DOOR ANCHORAGE (;:;Ro4ms) <br />Digitally signed by Signed and sealed by T.L. Hanson PE�\y� 11111ys/ <br />Thomas L <br />Thomas L using a Digital Signature and date. �p N E'• o� <br />Hanson :A 01410 Printed copies of this document <br />Hanson:A01410D00000 are not considered signed and 01 <br />DOOOOOI 77EF31 177EF31134E000015ADA sealed and the signature must be :LU- <br />Date: 2023.10.24 verified on any electronic co ' n '=w` <br />B4E000015ADA %�� �aa�°?'a�,� <br />U) <br />Z <br />_O <br />in <br />W <br />PROJECT NO. <br />2023-55 <br />DWG N0. <br />S 2A <br />