'I■I'�■�'IIAO!I' �I')II�I■�hAYI��1�■I�
<br />1
<br />ISOMETRIC VIEW
<br />PLUMBING
<br />EQUIPMENT SCHEDULE
<br />s
<br />C
<br />E^c
<br />o
<br />c
<br />; 1
<br />s
<br />o.%
<br />Itema
<br />°
<br />c co
<br />., o
<br />in
<br />o
<br />M
<br />�o
<br />min
<br />HE_
<br />Equipment o
<br />c
<br />a. 80
<br />x°
<br />c
<br />Manufacturer
<br />Model Number
<br />REMARKS
<br />7
<br />1
<br />3 COMP SNK
<br />1/2
<br />1/2
<br />2
<br />UNIVERSAL
<br />BS1512-3
<br />WASTE FROM EACH COMPARTMENT TO BE SEPARATELY DISCHARGED INDIRECTLY TO FLOOR SW
<br />B
<br />1
<br />WALL MOUNTED HAND SNK
<br />1/2
<br />1/2
<br />-1-1/2j
<br />WMANCE TABOO
<br />7-PS-40
<br />IWASIT TO BE DIRECTLY CONNECTED TO WASTE UW-PROVIDE THERMOSTATIC MW4 VALVE TO PROVIDE TEMPERED WATER BS' F. TO 110' F.
<br />GENERAL PLUMBING SPECIFICATIONS:
<br />1. ALL WORK UNDER THIS HEADING SHALL BE PERFORMED AND ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT
<br />COMPLIANCE WITH ALL RATINGS, CODES AND STANDARDS OR OTHER AUTHORITIES HAVING JURISDICTION.
<br />2• ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED FOR WORK UNDER THIS HEADING SHALL BE SECURED, PERFORMED
<br />AND PAID FOR BY THIS SUBCONTRACTOR AS A PART OF HIS CONTRACT.
<br />3. ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND FULLY EQUAL TO THE QUALITY SPECIFIED. WORK SHALL BE
<br />NOTE:
<br />EQUIPMENT REQUIREMENTS
<br />PERFORMED BY SKILLED MECHANICS AND WORKMANSHIP SHALL BE FIRST CLASS IN EVERY RESPECT. CONTRACTOR SHALL HAVE
<br />A COMPETENT SUPERINTENDENT (WHO IS EXPERIENCED IN THE WORK BEING INSTALLED UNDER THIS CONTRACT) IN CHARGE OF
<br />* THE DOMESTIC WATER PIPING SYSTEM SHALL BE FLUSHED WITH CLEAN
<br />WORK AT ALL TIMES DURING CONSTRUCTION.
<br />POTABLE WATER UNTIL CONTAMINATED WATER DOES NOT APPEAR AT THE
<br />OUTLET AND SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PPM OR
<br />CHLORINE AND ALLOWED TO STAND AS REQUIRED BY CODE BEFORE
<br />FLUSHING. THE SYSTEM SHALL BE FLUSHED COMPLETELY WITH CLEAR
<br />4. ALL PIPING SHALL HAVE THE MANUFACTURER'S NAME ROLLED INTO EACH LENGTH, OR SHALL OTHERWISE BE PROMINENTLY
<br />IDENTIFIED. AFTER CUTTING, ALL PIPE SHALL BE REAMED FULL BORE, AND ALL CUTTINGS, AND FOREIGN MATERIALS SHALL BE
<br />REMOVED BEFORE INSTALLATION.
<br />ITEM
<br />EQUIPMENT
<br />PLUMBING
<br />REQUIREMENTS
<br />REMARKS
<br />CW
<br />SIZE
<br />HW
<br />SIZE
<br />WASTE
<br />SIZE
<br />VENT
<br />SIZE
<br />MANUFACTURER/ MODEL
<br />WATER UNTIL ALL RESIDUAL CHLORINE CONTENT IS REMOVED.
<br />5. ALL SANITARY WASTE AND VENT PIPING SHALL BE PVC SCHEDULE 40, WITH FITTINGS OF THE SAME WEIGHT AS THE PIPE. UNDER
<br />CHLORINATION SHALL BE PERFORMED AFTER ALL PIPING AND FINAL
<br />CONNECTIONS AND PRESSURE TESTING HAVE BEEN COMPLETED.
<br />D.F.
<br />ADA COMPLIANT WALL HUNG
<br />BI-LEVEL DRINKING FOUNTAIN
<br />1/2"
<br />2"
<br />2•
<br />SUNROC ADAACB OR APPROVED
<br />EQUAL
<br />GROUND PIPING TO HAVE 1/4" PER FOOT SLOPE.
<br />6. ABOVE GRADE DOMESTIC WATER PIPE SHALL BE TYPE "L" SEAMLESS, HARD DRAWN COPPER TUBING AND TYPE "K" BELOW GRADE
<br />IN CONFORMANCE WITH ASTM B88-48. FITTINGS SHALL BE WROUGHT COPPER SUITABLE FOR 200 PSI. CONNECTIONS TO
<br />DISSIMILAR MATERIALS SHALL BE MADE WITH DIELECTRIC UNIONS. JOINTS SHALL BE 95-5 TIN ALTIMONY FOR 200 PSI. BELOW
<br />M.S.
<br />MOP SINK
<br />1/2"
<br />1/2"
<br />3"
<br />2•
<br />ADVANCE TABCO
<br />9-OP-20 OR APPROVED EQUAL
<br />WASTE TO BE DIRECTLY
<br />CONNECTED TO WASTE LINE.
<br />PLUMBING EQUIPMENT NOTES:
<br />JOINTS SHALL BE BRAZED.
<br />7. ALL FIXTURES SHALL HAVE INDIVIDUAL FIXTURE CONTROL VALVES WHICH SHALL BE CRANE, WATTS, NIBCO OR APPROVED
<br />EQUAL. VALVES OF EACH TYPE, SUCH AS GATE OR GLOBE, SHALL BE THE PRODUCTS OF ONE MANUFACTURER. VALVES SHALL
<br />BEAR THE NAME OR TRADEMARK OF THE MANUFACTURER AND THE WORKING PRESSURE CAST OR STAMPED ON THE VALVE
<br />BODY. MIN. 125 PSI. ALL VALVES SHALL BE ACCESSIBLE FOR EASE OF OPERATION.
<br />W.H.
<br />TANKLEGROUND
<br />HEATERSS ELECTRIC WATER
<br />3,4"
<br />3/4"
<br />TSTIEBEL EMPRA 2�223420
<br />OR APPROVED EQUAL
<br />O CONNECT NEW PLUMBING DRAIN LINES TO EXISTING SANITARY
<br />WASTE LINE, CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
<br />El
<br />SHOCK SUPPRESSORS
<br />AMTROL DIATROLS 537
<br />OR APPROVED EQUAL
<br />INSTALLED AS RECOMMENDED
<br />BY P.D.I.
<br />3
<br />O REUSE EXISTING 3" VENT THROUGH ROOF (VTR) AND CONNECT TO
<br />VENT LINES IN CEILING SPACE, CONTRACTOR TO VERIFY EXACT
<br />8. PROVIDE DIELECTRIC FITTINGS BETWEEN PIPING OF DISSIMILAR METALS AND AT WATER HEATER CONNECTIONS.
<br />El
<br />PREVENTER
<br />WATTS LSD-3 ASSE 1022
<br />EXIST. SANITARY
<br />WASTE LINE A
<br />SZ r_
<br />K 7
<br />8
<br />LOCATION IN FIELD.
<br />O CONNECT NEW PLUMBING WATER LINE TO EXISTING WATER SUPPLY
<br />LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
<br />O PROVIDEBACK EIS POSSIBLE.OW PVENTER AS SHOWN OR WHEREVER BACK
<br />9. PROVIDE 1/2" THICK FLEXIBLE UNICELLULAR FIRE RETARDANT INSULATION ON EXPOSED LAVATORY TRAP AND EXPOSED HOT AND
<br />COLD WATER SUPPLY AND ANY MISCELLANEOUS PIPING SUCH AS CONDENSATE PIPING. ALL JOINTS SHALL BE INSULATED AND
<br />SEALED WITH VAPOR BARRIER CEMENT.
<br />10. ALL PIPING, PIPE HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO JOISTS OR BEAMS. WHERE PIPING IS SUSPENDED
<br />FROM STEEL JOISTS THE CONNECTION SHALL BE MADE AT THE T P H R
<br />G
<br />ADA COMPLIANT WATER
<br />CLOSET
<br />1.
<br />3"
<br />2"
<br />ZURN Z5550 OR APPROVED
<br />EQUAL
<br />VITREOUS CHINA TOILET.
<br />1 � t3 I
<br />M.S.
<br />1 2"V '
<br />�0 0
<br />1
<br />NEW
<br />FCO H
<br />1 D.F. K
<br />EXIST.
<br />3" VTR M
<br />EXIST.
<br />WASTE PLAN
<br />SCALE: 1/4" = V-0"
<br />ISOMETRIC VIEW
<br />WATER PLAN
<br />SCALE: 1/4" = V-0"
<br />M.S. F❑
<br />O
<br />W.H. F
<br />CONTRACTOR SHALL VERIFY ALL
<br />EQUIPMENT & FIXTURES SPECS &
<br />UTILITY REQUIREMENTS WITH
<br />OWNER PRIOR TO ROUGH -IN.
<br />CONTRACTOR SHALL VERIFY
<br />EXISTING PLUMBING LINES AND
<br />UTILIZE AS MUCH AS POSSIBLE.
<br />ZURNZ5310 W/Z81104—XL—P
<br />VITREOUS CHINA. PROVIDE AND
<br />O C O D OF JOIST. PIPE SUPPORTS SHALL BE SPACED MO
<br />ADA COMPLIANT RESTROOM
<br />4"CENTERSET FAUCET
<br />INSTALL THERMOSTATIC MIXING
<br />MORE THAN 10 FEET APART. NOTHING SHALL BE ATTACHED DIRECTLY TO THE DECK, CEILING SYSTEM OR DUCT WORK ABOVE.
<br />El
<br />WALL HUNG LAVATORY &
<br />1/2"
<br />1/2"
<br />2"
<br />2"
<br />WITH 4" WRIST BLADE HANDLES
<br />VALVE TO PROVIDE TEMPERED
<br />FAUCET
<br />AND POP—UP OR APPROVED
<br />WATER (85' F. TO 110' F.) AT
<br />11. HANGERS SHALL NOT PIERCE PIPING INSULATION VAPOR BARRIER.
<br />EQUAL
<br />ALL PUBLIC LAVATORY.
<br />12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY DAMAGE DONE TO THE FIRE PROOFED STRUCTURAL STEEL SERVING
<br />El
<br />THERMOSTATIC MIXING VALVE
<br />1/2"
<br />1/2"
<br />WATTSSERIES MMV—UT—M1 1/2"
<br />ADJUST TO PROVIDE TEMPERED
<br />HOT WATER (85' TO 110- F.)
<br />THE FIRST FLOOR.
<br />OR
<br />FROM PUBLIC LAVATORY(S)
<br />13. ALL HANGERS, RODS, BEAM CLAMPS ETC. EXPOSED TO PUBLIC VIEW SHALL BE PAINTED TO MATCH ADJACENT FINISHES AND BE
<br />FAUCET(S)
<br />MANUFACTURED BY F&M, GRINNEL, OR CENTRAL FOUNDRY,
<br />14. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT SPACE (AND THROUGH THE ROOF) ARE
<br />PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT POSSIBLE WATER LEAKAGE AND/OR DAMAGE. ANY DAMAGE CAUSED
<br />El
<br />FLOOR SINK
<br />4•
<br />2"
<br />JOSAM 49300 & 49310
<br />SERIES. SUPER—FLO,
<br />6" MEDIUM DEEP BODIES
<br />FROM FAILURE TO DO SO SHALL BE A CONTRACTOR'S SOLE RISK AND EXPENSE. ALL ROOF AND SLAB PENETRATIONS MADE BY
<br />8" SQUARE TOPS
<br />THE CONTRACTOR ARE SUBJECT TO L.L. APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. ALL PENETRATIONS IN ROOF
<br />AND CEILING SHALL BE FIRE CAULKED.
<br />JOSAM 30000—S SERIES OR
<br />PROVIDE AND INSTALL TRAP PRIMER
<br />FLOOR DRAIN
<br />3"
<br />2"
<br />APPROVED EQUAL BOTTOM OUTLET
<br />WITH SUPER—FLO SQUARE NIKALOY
<br />ONLY IF REQUIRED BY LOCAL CODE.
<br />15. PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW DEEP TYPE, TO COVER SLEEVES OR OF A SIZE TO COVER
<br />STRAINER
<br />WASTE TO BE DIRECTLY
<br />CONNECTED E WASTE LINE.
<br />FITTING PROJECTIONS, PROVIDE ESCUTCHEONS FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS, AND EXPOSED CEILINGS.
<br />16. THE CONTRACTOR SHALL CORE DRILL EXISTING FLOOR SLAB AS REQUIRED FOR INSTALLATION OF UNDERSLAB UTILITIES.
<br />CONTRACTOR MUST COORDINATE ALL INSTALLATION OF BELOW -SLAB SERVICES WITH L.L. ALL MODIFICTIONS TO THE SLAB
<br />N❑
<br />1/2"
<br />ZURN Z-1022 SANI—GARD.
<br />CONNECT TO CW W/VALVE, EXTEND
<br />INSTALL ONLY IF REQUIRED
<br />TRAP PRIMER
<br />TPP TO FLOOR DRAIN AS REQUIRED
<br />BY LOCAL CODE.
<br />SHALL BE REPAIRED BY APPROVED L.L. METHODS THAT MEET OR EXCEED THE ORIGINAL SLAB DESIGN INCLUDING
<br />WATERPROOFING. THE CONTRACTOR SHALL PROPERLY SLEEVE AND SEAL ALL PENETRATIONS TO COMPLY WITH L.L AND CODE
<br />C/O
<br />WALL CLEAN -OUT - ZURN, #Z-1441, SMOOTH STAINLESS STEEL ACCESS COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE.
<br />REQ.'S.
<br />17. ALL UTILITIES NOT RE -USED SHALL BE CAPPED -OFF AND REMOVED. DISPOSAL SHALL BE PER L.L. APPROVED METHOD(S). NO
<br />FCO
<br />FLOOR CLEANOUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE.
<br />UTILITIES SHALL BE ABANDONED IN PLACE.
<br />NOTE:
<br />VERIFY FINAL PLUMBING REQUIREMENTS WITH EQUIPMENT CUT SHEETS AND PLANS PRIOR TO THE START OF WORK TO AVOID ANY CONFLICTS.
<br />18. COORDINATE ALL PENETRATIONS FLOOR, DRAINS/SINKS W/ WATERPROOFING OF SLAB.
<br />8 7/8" x 3 5/8" x 3 DRAIN LINE
<br />3/4" HIGH FUNNEL.
<br />IF SPECIFIED.
<br />I
<br />I I
<br />FLOOR GRATE.I
<br />I �
<br />MOUNT AIR GAP = 2 x "d"
<br />FLUSH
<br />wrrrr—
<br />FLOOR vo v vv
<br />LIFT OUf ALUMINUM
<br />b SEDIMENT BUCKET.
<br />19!
<br />FLOOR
<br />UNION
<br />HW SUI
<br />HUB OUTLET
<br />FLOOR SINK DETAILEL
<br />SCALE: NONE
<br />CHECK VALVE
<br />:W SUPPLY
<br />PROVIDE DIELECTRIC
<br />FITTINGS AT WATER
<br />WATER HAMMER HEATER CONNECTIONS
<br />ARRESTORS
<br />REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE
<br />INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC;
<br />ADJUST AS REQUIRED TO SUIT ACTUAL CONDITIONS. VERIFY
<br />CONNECTION SIZES AND LOCATIONS WITH WATER HEATER
<br />FURNISHED. REFER TO FLOOR PLANS FOR PIPE SIXES. PROVIDE
<br />SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL
<br />AUTHORITIES. PROVIDE HEAT TRAP AND AUTOMATIC VACUUM
<br />RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES.
<br />WATER HEATER DETAIL
<br />SCALE: NONE
<br />MA)
<br />AS'
<br />OR
<br />CLE
<br />TEE
<br />CL
<br />DI.
<br />MA
<br />INSTALL ONLY IF REQUIRED BY LOCAL CODE
<br />FOR WALL CONST.
<br />1/2" TRAP PRIMER SUPPLY
<br />SEE ARCH. DWGS.
<br />DOMESTIC WATER LINE
<br />CLEANOUT
<br />PLUG
<br />COUNTERSUNK
<br />SCREW
<br />TRAP PRIMER VALVE
<br />POLISHED S.S. DISTRIBUTION UNIT, FOR
<br />ACCESS COVER UP TO 4 LINES
<br />FLUSH w/ WALL
<br />WASTE LINE w/
<br />LENGTH TO SUIT
<br />AT END OF
<br />4NOUT
<br />_\L I I I =J MAIN WASTE LINE
<br />WALL CLEANOUT DETAIL
<br />SCALE: NONE C/O
<br />CLEANOUT AND ACCESS
<br />COVER. TOP OF COVER
<br />TO BE FLUSH W/TOP OF
<br />=LOOR LINE
<br />END
<br />E LINE
<br />'H TO SUIT
<br />E LINE
<br />1/0 DCIVU Lr %_LCHIVVUT
<br />OCCURS AT END OF LINE
<br />FLOOR CLEANOUT DETAIL
<br />NO SCALE
<br />FCO
<br />1/2" TRAP PRIMER LINE
<br />SLEEVE THRU
<br />SLA
<br />TRAP PRIMER CONNECTION DETAIL
<br />SCALE: N.T.S.
<br />THERMOSTATIC MIXING VALVE
<br />REDUCERv
<br />1/2"-3/4" HW & CW
<br />WHEN APPLICABLE:
<br />HW BRANCH FROM
<br />RECIRCULATING MAIN
<br />LOOP, KEEP SHORT
<br />AS POSSIBLE.
<br />UNIONS �1/2"-3/4" TW TO FIXTURE(S),
<br />KEEP SHORT AS POSSIBLE.
<br />NOTE:
<br />INSTALL ABOVE CEILING OR IN WALL CAVITY
<br />WITH 12"x12" ACCESS DOOR WHERE REQUIRED El
<br />THEFfi l" IOSTATIG MIXING VALVE PETAL
<br />NOT TO SCALE
<br />SYMBOL CODE
<br />-�---
<br />COLD WATER PIPING
<br />----------
<br />HOT WATER PIPING
<br />- - - - - - - - - -
<br />- FILTERED WATER PIPING
<br />- - - - - - - - - - -
<br />— INDIRECT WASTE PIPING
<br />SAN. WASTE PIPING
<br />— — — — — —
<br />— - EXIST. SAN. WASTE
<br />PIPING
<br />---------
<br />WASTE VENT PIPING
<br />SHUT OFF VALVE
<br />.1
<br />UNION
<br />T & P RELIEF VALVE
<br />&__
<br />VALVED WATER TAP
<br />1
<br />CONNECT TO EXISTING
<br />STRAINER, FLUSH
<br />w/
<br />El
<br />1/2" TRAF
<br />PRIMER
<br />DRAIN SU
<br />DEEP SEA
<br />FLOOR DRAIN D ETAI L
<br />SCALE: N.T.S.
<br />FLOOR FINISH
<br />AIN - 1/4"/FT. MIN.
<br />ADJUSTABLE
<br />DRAIN HEAD
<br />DRAIN BODY
<br />INSIDE CAULK
<br />PIPE
<br />0
<br />BEFORE PERMITTING OR START OF CONSTRUCTION:
<br />1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS
<br />2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS.
<br />3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC
<br />ISSUED FOR: REVIEW
<br />11.01.2021
<br />z
<br />F
<br />a_
<br />FE
<br />U
<br />N
<br />w
<br />0
<br />w
<br />�I
<br />0_w>-In-OZtn
<br />C)
<br />LO
<br />Q
<br />co
<br />O
<br />I-�
<br />w
<br />z
<br />H�
<br />a,
<br />x
<br />x
<br />a
<br />Q
<br />J
<br />ON.
<br />0
<br />0
<br />N
<br />Z
<br />w
<br />O
<br />(�
<br />D
<br />J
<br />W
<br />�
<br />i
<br />F:.
<br />8
<br />Lo
<br />__l
<br />L
<br />U
<br />V
<br />Z
<br />W
<br />0.
<br />IL
<br />t3f
<br />Lp
<br />I` O
<br />� U
<br />coII O?
<br />Lnz
<br />H
<br />I�
<br />O
<br />r—
<br />V1
<br />�
<br />N
<br />E O
<br />W
<br />w
<br />z
<br />THF�
<br />V
<br />w
<br />co
<br />co
<br />z
<br />a
<br />L)
<br />ns
<br />EO
<br />V1
<br />N
<br />a
<br />O
<br />E)
<br />A~
<br />8
<br />ai
<br />O
<br />l Fj
<br />IL
<br />W
<br />�
<br />a
<br />co
<br />T1
<br />JOB. N0.21040
<br />GC
<br />�1
<br />COA. NO.29116
<br />MAZEN MARIE, PE.
<br />(F . PE
<br />0166)
<br />P-1
<br />
|