END VANES SPUTTER <br />VANES <br />SHALL BE <br />IU71 LOCATED AT <br />ELBOW WHEEL <br />IN <br />BACK OF DUCTWORK R <br />SHALL NOT BE VISIBLE \ <br />VANE SHALL FROM POINT IN <br />COVER ELBOW OUT W <br />THROAT <br />IF RAN < 1.0 <br />PROVIDE SPUTTER VANES. <br />THIS DETAIL APPLIES TO 90• RADIUS ELBOWS AND LESS <br />THAN 90• RADIUS ELBOWS AND ANY RECTANGULAR <br />DUCT LESS THAN 90•. <br />VOLUME DAMPER <br />VOLUME DAMPER ON <br />bxc c RETURN DUCT ONLY. <br />(8-b)ro DOUBLE OR axc <br />SINGLE BLADE <br />TURNING VANES SPUTTER DAMPER ON <br />12• 15• SUPPLY DUCTS ONLY <br />(a+bpcc <br />MAIN SUPPLY, <br />RETURN <br />OR EXHAUST <br />DUCTWORK <br />15' <br />FOR ALL SUPPLYIRETURN DUCT SUPPLY RETURN TO DIFFUSER <br />BRANCHES. OR RETURN OR <br />©CONNECTION AT SIDE, 45• EXHAUST GRILLE <br />TOP OR BOTTOM OF <br />DUCT. END OF DUCT <br />TO HAVE AIR <br />BALANCING <br />MINIMUM I2' ? I J MINIMUM STRAIGHT <br />DAMPER (TYP.). <br />STRAIGHT r?u `II IL FROM DUCT <br />TTRAANNSMOONN y TRANSITION <br />VOLUME DAMPER AT <br />BRANCH TAKEOFFS (TYP.) <br />BRANCH <br />TURNING DAMPER <br />VANES L RRN <br />(TYP-) <br />DAMPER a MAIN DUCT <br />BRANCH o <br />c a <br />c <br />v 6 046 <br />/ SUPpL� TRANSITION SPLIT <br />IF REQUIRED <br />TYPICAL BRANCH DUCT & <br />NOT TO SCALE <br />MINIMUM OF 1 SUPPORT IF <br />DUCT IS LESS THAN 4' LONG <br />1;0. <br />@1 DUCT SHOULD EXTEND STRAIGHT FOR <br />FAO SEVERAL INCHES FROM A CONNECTION <br />P BEFORE BENDING. SHARP BENDS ARE <br />6b NOT ALLOWED. <br />l,y 1MGM <br />45• FITTING.—' <br />MAXIMUM SAG 1/2• PER FOOT <br />(41.7 mm PER m) <br />OF SUPPORT SPACING <br />NOTE: CLOSER MAXIMUM HANGER INTERVALS MAY BE SPECIFIED AS A CONDITION OF U.L. LISTING, PARTICULARLY <br />IN FIRE RATED FLOOR -CEILING ASSEMBLIES. <br />FLEXILE DUCT SUPPORTS DETAL <br />NOT TO SCALE <br />AS PER HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE SMACNA - THIRD <br />EDITION <br />OUTSIDE AIR <br />INTAKE <br />FACTORY <br />FABRICATED, / <br />INSULATED <br />ROOF CURB <br />DUCT <br />VIBRATION <br />ISOLATION <br />CONNECTORS <br />TRANSITION AS REQ'D TO <br />INLET/OUTLET OF AHU <br />GALVANIZED HOLD <br />DOWN STRAP <br />18" LONG 4X4 TREATED <br />WOOD BLOCK <br />E <br />1"THICK RIGID INSULATION <br />ADHERED TO WOOD BLOCK <br />PLACE RTU ON ROOF CURB. PROVIDE CONTINUOUS <br />GASKET ON CAP OF ROOF CURB. SECURE RTU AS PER <br />ARCHITECTURAUSTRUCTURAL DRAWINGS. <br />I"CONDENSATE <br />DRAIN LINE WITH <br />TRAP. <br />(DISCHARGE TO <br />NEAREST ROOF <br />RTU <br />DRAIN) <br />ROOF <br />- ® ROOFNOIST CAPACITY AS <br />PER ARCH/STRUCT <br />ROOFTOP DETAL <br />SCALE: NOT TO SCALE <br />GAS/ <br />CONDENSATE/ <br />REFIGERANT <br />PIPING <br />18• LONG 2X12 TREATED <br />WOOD SECURED TO 4X4 <br />WITH GALVANIZED <br />HARDWARE <br />PFNNO SUPPORT DETAIN. ON ROOF <br />SCALE: NOT TO SCALE <br />NIC MECHAAL DUALS <br />12. SCALE: NOT TO SCALE <br />MECHANICAL DETALS <br />SCALE: NOT TO SCALE <br />GLOBAL <br />S�Cnc�I�C <br />MEPF ENGINEERING <br />INFOPQ OL09AL-SANCH E- DOM <br />CAI: 6237 <br />B 1 6 MANATEE AVE. E, SUITE 16 <br />BRADENTON, FL 34208 <br />PHONE: 941-758-2551 <br />3825 HENDERSON BLVD., <br />SUITE 103 <br />TAMPA. FL 33629 <br />PHONE: 8 <br />1 3-26 7.000 1 <br />C&K ARCHITECTS I INTERIORS <br />eldxorxwre.arcarla assign. aom 829 <br />A4co01axa <br />4221 WEST BOY SCOUT BI VD., SURE 150 <br />TAMPA, FL 336D7-5743 <br />813.884.20DO <br />280 WEST CENTRAL AVE. <br />WINTER HAVEN. FL 33880.2957 <br />963.577.2054 <br />5�W A SF <br />C E NSF •�1! <br />�P��,,,•''�,� <br />*'N o. 71454 <br />t <br />5/14/20211W <br />O \ STATE OF f? <br />F`s•••.. FC OR10Pr' <br />G� <br />S10NAL <br />e <br />a <br />7 <br />W <br />c!a � <br />J 0 <br />H � <br />W <br />0 <br />� <br />IL <br />U �O <br />CL <br />N <br />O <br />V <br />Lu <br />G m <br />J <br />m <br />0. <br />a <br />m <br />WWKfE <br />PERMIT <br />1e wmwm <br />21020 <br />DAIS <br />5.5.21 <br />DuweK mwm <br />mg. i <br />