STRUCTURAL SPECIFICATIONS <br />L GENERAL <br />I. SUBCONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION TO ENSURE THE <br />SAFETY OF THE BUILDING UNTIL STRUCTURAL SYSTEM IS COMPLETED. THIS INCLUDES, BUT IS NOT <br />LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, SHORING, GUYS TO TIE -DOWNS THAT <br />MAY BE NECESSARY. <br />2. SUBCCNTRACtOR 18 SOLELY RESPONSIBLE FOR T4E SAFETY OF HIS WORK DURING* CONSTRUCTION. <br />3. APPLICABLE BUILDING CODES: - FLORIDA BUILDING CODE (2014). DRAWINGS ARE CERTIFIED FOR <br />STRUCTURAL PORTION ONLY THAT INCLUDES FOUNDATION SYSTEMS, BEAMS, POSTS, SHEARWALLS, <br />STRUCTURAL CONNECTORS, REQUIRED WIND DESIGN PRESSURES, FASTENERS, SHEATHING MATERIAL AND <br />THICKNESS, WALL STRUCTURAL ELEMENTS, HEADERS OVER WINDOWS, REINFORCED CONCRETE, STEEL <br />FRAMING, WOOD FRAMING, MASONRY SIZES AND REINFORCEMENT, AND SPECIFICATIONS DESCRIBED HEREIN. <br />4. DESIGN LOADS: <br />A. ROOF: <br />LIVE LOAD 20 PSF <br />DEAD LOAD 10 PSF (SHINGLES s METAL) <br />20 PSF (TILE) <br />B. UNINHABITABLE ATTICS WITH LIMITED STORAGE <br />LIVE LOAD 20 PSF <br />DEAD LOAD 10 PSF <br />C. FLOOR <br />BALCONIES LIVE LOAD 60 PSF <br />ALL OTHER ROOMS LIVE LOAD 40 PSF <br />DEAD LOAD 10 PSF <br />D. SNOW AND SEISMIC LOAD: NONE <br />S. STRUCTURAL MEMBER ALLOWABLE DEFLECTION <br />Rafters having slopes greater than 3:12 with no finished calling attached to rafters <br />LASO <br />Interior walls and partitions <br />WASO <br />Floors and plastered ceilings <br />L/360 <br />All other structural members <br />L/140 <br />Exterior we Ile <br />H/360 <br />Lintels supporting maeorrg veneer walls <br />L/600 <br />6. ALL CONTRACTORS, SUBCONTRACTORS, SUPPLIERS AND FABRICATORS <br />SHALL BE RESPONSIBLE FOR THE CONTENT OF DRAWINGS, AND FOR THE <br />SUPPLY AND DESIGN OF APPROPRIATE MATERIALS AND WORK <br />PERFORMANCE. <br />1. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL <br />13E APPLIED, INSTALLED, ERECTED, USED, CLEANED, AND CONDITIONED IN STRICT <br />ACCORDANCE WITW MANUFACTURER'S RECOMMENDATIONS. <br />8. ALL STUCCO FINISH SHALL BE APPLIED AS PER ASTM C926 AND CONTROL JOINTS <br />PROVIDED AS PER ASTM C1063. CURING TIME AS PER SECTION R104b9 OF T14E <br />FLORIDA BUILDING CODE 5TH EDITION (2014). <br />II. SITE WORK <br />I. FOUNDATION DESIGN IS BASED ON A MINIMUM SOIL PRESSURE INDICATED ON THE <br />FOUNDATION PLAN. THE CONTRACTOR IS RESPONSIBLE TO FOLLOW RECOMMENDATIONS <br />INCLUDED IN THE RESPECTIVE GEOTECHMNICAL REPORT AND SHALL CONFIRM THE SOIL <br />CONDITIONS. SHOULD FIELD CONDITIONS INDICATE THIS MINIMUM CONDITION DOES NOT <br />EXIST, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER OF RECORD. <br />2. THE SUBGRADE UNDER THE NEW CONCRETE FOUNDATIONS SHALL BE COMPACTED <br />TO 95% OPTIMUM DENSITY. SOIL COMPACTION TESTS TO BE TAKEN BY A <br />QUALIFIED SOILS LAB PRIOR TO POURING ANY CONCRETE. <br />3. FOOTINGS SHALL BE NEAT EXCAVATED WHERE POSSIBLE WITH SIDES AND TOP EDGES <br />FREE OF LOOSE OR WET MATERIALS. WHERE NEAT EXCAVATION IS NOT POSSIBLE, <br />FOOTINGS EXCAVATION SHALL BE OPEN CUT WITH EDGES FORMED AND BRACED. ALL <br />FOOTINGS WITH FORMED EDGES SHALL BE BACKFILLED FROM BOTTOM TO TOP OF <br />FOOTING WITH SELECT FILL. THE BOTTOM EXCAVATION SHALL BE CLEAN AND DRY <br />WITH ALL LOOSE MATERIAL REMOVED FOR AN ESSENTIALLY FLAT BEARING SURFACE. <br />III. CAST IN PLACE CONCRETE <br />1. CONCRETE TO BE NORMAL WEIGHT WITH THE FOLLOWING MINIMUM COMPRESSIVE <br />STRENGTHS AT 28 DAYS: <br />as FOOTINGS, SLAB -ON -GRADE, SLAB FILL: 2500 PSI <br />ba MASONRY WALL TIE BEAMS, TIE COLUMNS: 2500 PSI <br />ca REINFORCED CONCRETE BEAMS AND COLUMNS 3000 PSI <br />2. CONCRETE SHALL BE READYMIX PER ASTM C94: <br />a.) PORTLAND CEMENT - ASTM 0150 <br />ba A:CGREGATES - ASTM C33 (3/4" MAX.) <br />ca NO CALCIUM CHLORIDE <br />des AIR ENTRAINING - ASTM C260 <br />ea WATER REDUCING - ASTM C494 <br />fa FLYASH - ASTM C618-18 CLASS F (20 % MAX-) <br />g-) WATER - CLEAN AND POTABLE <br />3. REINFORCING STEEL: ASTM1 A615 GRADE 40, DEFOIRMED BARS. <br />4. REQUIRED SLUMP RANGE ■ 3" TO 511. <br />5. WELDED WIRE FABRIC: ASTM A1S5 <br />6. MOISTURE BARRIER 6 MIL POLYETHYLENE. <br />1. CODES AND STANDARDSt <br />a.) ACI 301 "SPEC FOR STRUCTURAL CONCRETE FOR BUILDINGS." <br />ba ACI 305 "RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING." <br />c-) ACI 318 "BLOC. CODE REQUIREMENTS FOR REINF. CONCRETE." <br />des ACT 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." <br />e. MINIMUM LAP SPLICE - 40 BAR DIAMETERS UNLESS NOTED OTHERWISE. <br />9 CONCRETE FINISHES SHALL BE PER CONTRACTOR'S SPEC'S. <br />10. SUBCONTRACTOR IS RESPONSIBLE FOR THE PROPER DESIGN AND CONSTRICTION <br />OF ALL FORMWORK, SHORING, AND RESHORING. <br />11. REINFORCING BAR COVER <br />as FOOTINGS 3" <br />ba COLUMNS 1 1/2" <br />ca BEAMS AND WALLS 1 1/2" <br />des SLABS 3/4" (INTERIOR), 1 1/2" (EXTERIOR) <br />12. CONCRETE SHALL BE PLACED WITHIN 90 MINUTES OF BATCH TIME. <br />13. PROVIDE CORNER BARS AT ALL WALL FOOTING AND BEAM CORNERS TO MATCH <br />HORIZONTAL BARB. (25" MINIMUM LAP FOR 5 BARS, OTHERS AS PER ACI 318). <br />14. ALL BUILDING SLABS -ON -GRADE SHALL BE NOMINAL 4" THICK, REINFORCED WITH bxb-111I.4 W.WP. <br />ON 6 MIL VAPOR BARRIER SEE PLANS FOR OTHER CONDITIONS AND SIZES. NO FIBERMESH <br />ALLOWED UNLESS OTHERWISE NOTED ON THE FOUNDATION PLAN. <br />ID. ANCHOR BOLTS FOR WOOD LEDGERS AND PLATES TO CONCRETE OR MASONRY (OPTIONS).. <br />a. J BOLTS - USE 1/2" X 8" "J" BOLTS WITH 6" EMBEDMENT AND 2" PROJECTION WHEN INSTALLED <br />PRIOR TO PLACING CONCRETE, AS SHOWN ON DRAWINGS. <br />b. EXPANSION ANCHORS - USE 1/2" X 4" EMBED, HILTI KWIK BOLT 11, OR EQUAL, AT LOCATIONS <br />(OTHER THAN EDGE CONDITIONS) IN LIEU OF 1/2" X 8" "J" BOLTS. <br />a EPDXY ANCHORS IN CONCRETE - USE 1/2" X 4-1/4" IMBED, WITH HILTI C100), OR ANCHOR <br />BOND BY CELTITE, INC., AT EDGE OF SLAB CONDITION WHERE BOLT IS LESS THAN 6" TO <br />A CONCRETE EDGE. <br />d. EPDXY ANCHORS IN TOP OF BLOCK WALLS - USE THREADED ROD (3/4" X A6-5/8" IMBED) ON <br />TOP OF 8" MASONRY WALLS WITH HILTI HIT C-100 ADHESIVE OR ANCHOR BOND, WHEN 1/2" X 8" <br />"J BOLTS ARE OMITTED. <br />16. FOOTING SIZES SHOWN ARE TYPICAL ONLY FOR STATED SOIL BEARING PRESSURE AND <br />CONSISTED COMPACTION. CONTRACTOR SHALL BE RESPONSIBLE FOR FOOTINGS <br />COMPLYING WITH THE DESIGN REQUIREMENTS OF SPECIFIC SOIL CONDITIONS. <br />11. PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL CONCRETE SLABS AND <br />ABUTTING CONCRETE OR MASONRY WALLS OCCURRING IN EXTERIOR OR UNHEATED AREAS. <br />10. PROVIDE 1/4" SAW CUT EXPANSION JOINTS ON SLABS SPACED AT NO MORE THAN 18 FEET ON <br />CENTER EACH WAY AND AS SHOWN ON PLANS <br />IV. MASONRY <br />I. HOLLOW LOAD BEARING UNITS (CMU) SHALL CONFORM TO ASTM C90, NORMAL WEIGHT, TYPE I, GRADE N. <br />MINIMUM NET COMPRESSIVE STRENGTH ■ ISM PSI. <br />2. MORTAR SHALL BE TYPE M OR 6 AND CONFORM TO ASTM C210. <br />3. CONCRETE GROUT SHALL CONFORM TO ASTM C416: <br />a-) 2,500 PSI AT 28 DAYS. <br />b.)3/8" MAXIMUM AGGREGATE. <br />C.) 8" - 11" SLUMP. <br />4. BARS SHALL HAVE MINIMUM CLEARANCE OF 1/2" FROM MASONRY. THE CLEAR DISTANCE <br />BETWEEN BARS SHALL NOT BE LESS THAN ONE BAR DIAMETER NOR LESS THAN I". <br />5. VERTICAL REINFORCING SHALL BE AT ALL CORNERS, EACH JAMB OF OPENINGS, UNDER ALL <br />GIRDER LOADS, AND NOT TO EXCEED 6'0" O/C FOR STRAIGHT WALLS, OR AS SHOWN ON THE <br />DRAWINGS. FILL CELLS WITH CONCRETE GROUT AS SPECIFIED. PROVIDE ACI 318 90 DEGREE <br />STANDARD HOOKS INTO FOOTING, AND TIE BEAMS. <br />6. REINFORCING BARB SHALL BE STRAIGHT EXCEPT FOR BENDS AROUND CORNERS AND WHERE <br />BENDS OR HOOKS ARE DETAILED ON THE PLANS. <br />1. REINFORCING BARS SHALL BE LAPPED 40 BAR DIAMETERS WHERE SPLICED AND SHALL <br />BE WIRED TOGETHER- <br />S. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE <br />SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL. DOWELS SHALL BE GROUTED INTO A <br />CORE IN VERTICAL ALIGNMENT, EVEN THOUGH IT IS IN AN ADJACENT CELL TO THE VERTICAL <br />WALL REINFORCEMENT. <br />9. CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE OF MASONRY IN EACH GROUT <br />POUR WHEN THE POUR HEIGHT EXCEEDS 5. PROVIDE 4" X 4" OBSERVATION HOLE TO <br />VERIFY CONCRETE GROUT PLACEMENT. <br />10. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS. PROVIDE COMPLETE <br />COVERAGE FACE SHELL MORTAR BEDDING, HORIZONTAL AND VERTICAL. FULLY <br />MORTAR WEBS IN ALL COURSES OF PIERS, COLUMNS, AND PILASTERS AND <br />AND ADJACENT TO GROUTED CELLS. <br />II. PROVIDE 8" X 8" PRECAST REINFORCED CONCRETE LINTELS OVER ALL MASONRY OPENINGS <br />NOT SHOWN TO HAVE A STRUCTURAL 5EAI't MINIMUM END BEARING - 4" <br />REFER TO LINTEL SCHEDULE (MINIMUM CAPACITY OF 1000 PLF). <br />12. PROVIDE METAL CAVITY CAPS, 6" WIRE MESH, OR EQUAL PRODUCTS, INC, WERE <br />REQUIRED TO RETAIN GROUT IN VERTICAL CELLS. <br />13. PROVIDE HORIZONTAL REINFORCEMENT AT EVERY OT14ER COURSE USING 120 TRUSS -MESH BY <br />HOHMANN 1 BARNARD. <br />V. CARPENTRY <br />1. DIMENSIONED LUMBER SHALL BE DRESSED 646, AND SHALL BEAR THE GRADE STAMP <br />OF THE MANUFACTURER'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />3. ALL STRUCTURAL BEAMS AND HEADERS SHALL BE SOUTHERN YELLOW PINE (SYPa NO. I <br />GRADE OR BETTER WITH SINGLE MEMBER (UNFACTORED) STRESSES AS FOLLOWS: <br />Fv ■ 90 PSI <br />Fo ■ 915 PSI <br />E - 1i6000M PSI <br />IS% MAXIMUM MOISTURE CONTENT <br />A. FRAMING LUMBER SHALL BE 02 SPRUCE -PINE -FIR OR BETTER <br />B. INTERIOR NON -LOAD BEARING WALLS MAY BE UTILITY GRADE. <br />4. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. <br />5. PRESSURE TREATED LUMBER SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />AMERICAN WOOD PROTECTION ASSOCIATION LATEST STANDARDS. <br />6. SHEATHING FOR ROOFS AND WALLS SHALL BE APA RATED (EXPOSURE U SHEATHING <br />WITH EXTERIOR GLUE. ALL ROOF SHEATHING TO IS£ INSTALLED WITH PLYCLIPB. (MAXIMUM <br />24" O/C). THICKNESS TO BE MINIMUM 15/32" FOR SHINGLE ROOF AND 1/2" FOR TILE ROOF. <br />1. NAILING FOR PLYWOOD ROOFS AND WALL SHEATHING SHALL BE SD RING SHANK a <br />4" O.C. a PANEL EDGES, AND 6" O.C. INTERMEDIATE, FOR 1/2" SHEATHING OR <br />LESS. NAILING FOR STRUCTURALLY APPROVED ARCHITECTURAL WALL PANELS (1/4"+) <br />SHALL BE 60 COMMON a 4" O/C At PANEL EDGES, AND 6" O/C INTERMEDIATE. <br />S. ALL FLOORING MATERIAL TO BE 3/4" T1G PLYWOOD, NAILED AND GLUED TO FLOOR <br />JOISTS. FLOOR NAIL WITH 10d NAILS AT 3" O/C AT PANEL EDGES, 6" O/C IN THE <br />FIELD. STAGGER NAILS AT 2" O/C AT BUTT ENDS OF PLYWOOD SHEATHING. <br />9. INSTALL BRIDGING IN ALL (2X) FLOOR OR ROOF JOISTS AT 8'-0" MAXIMUM. <br />INSTALL BLOCKING IN ALL BEARING* WALLS AND PARTITIONS OVER V-0" e <br />MID -HEIGHT. BRACE GABLE END WALLS At WO" O/C WHERE WALL FRAMING IS <br />NOT CONTINUOUS FROM FOUNDATION TO ROOF, OR AS SHOWN ON DRAWINGS. <br />10. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION <br />REQUIREMENTS. ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. <br />11. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY SIMPSON <br />STRONGTIE CO, OR EQUIVALENT. SUBMIT CUT SHEETS FOR ALL CONNECTION <br />HARDWARE TO CONTRACTOR FOR APPROVAL. ALL NAIL HOLES SHALL BE FILLED <br />OR AS PRESCRIBED BY THE MANUFACTURER <br />12. PROVIDE A SINGLE PLATE AT THE BOTTOM AND DOUBLE PLATE AT THE TOP OF ALL <br />LOAD BEARING STUD WALLS. STAGGER END JOINTS IN DOUBLE PLATES AT LEAST W-0" <br />PER DETAIL. 2 X 4 SILL PLATES FOR BEARING WALLS SHALL BE BOLTED TO <br />FOUNDATION AS PER BEARING WALL DETAIL. <br />13. LOAD BEARING STUDS SHALL BE DOUBLED AT ALL ANGLES AND AROUND ALL OPENINGS, <br />AND AT STRUCTURALLY APPROVED ARCHITECTURAL WALL PANEL JOINTS. STUDS SHALL <br />BE TRIPLED AT ALL CORNERS. <br />14. WOOD LINTELS OVER OPENINGS SHALL BE DOUBLED 2x12 14EADERS UNLESS <br />NOTED OTHERWISE ON PLANS, WITH CONTINUOUS 1/2" PLYWOOD FILLER CUT TO <br />FULL DEPTH OF BEAM BETWEEN 2x MEMBERS. <br />15. RAFTER SCHEDULE FOR CONVENTIONAL FRAMED AREAS UNLESS OTHERWISE NOTED. <br />MAXIMUM <br />MEMBER SIZE SPAN (SYP 01) <br />2 X 4 6FT. <br />2X6 SFT. <br />2 X 8 10 FT. <br />2 X 10 12 FT. <br />2 X 12 14 FT. <br />NOTE 1: RAFTERS MUST BE BRACED LATERALLY BY A CONTINUOUS NAILING OF <br />SHEATHING OR BRACED AT 24" 0/0, WITH MINIMUM IX4. <br />NOTE 2. RAFTER SPACING NOT TO EXCEED 24" O/C. <br />NOTE 3: RIDGE BOARDS TO BE ONE SIZE LARGER THAN RAFTER UNLESS <br />OTHERWISE NOTED ON PLANS. <br />NOTE 4: CONNECTOR SCHEDULE <br />A. SIMPSON MTS20 (OR EQUAL) BETWEEN CAT BLOCKING AND ROOF TRUSSES. <br />B. SIMPSON H5 (OR EQUAL) BETWEEN RAFTER TAILS TO CAT BLOCKING. <br />C. SIMPSON H5 (OR EQUAL) BETWEEN THE RAFTERS AND RIDGE BOARD. <br />D. SIMi'SON C620 AT ENDS OF RIDGE BOARD, OR SIMPSON JOIST <br />HANGER WHERE APPLICABLE. <br />VI. PRE-ENGINEERED WOOD TRUSSES <br />I. THIS SECTION DEFINES PRE-ENGINEERED, PREFABRICATED, METAL PLATE CONNECTED <br />WOOD ROOF AND FLOOR TRUSSES AS "WOOD TRUSSES". <br />2. TRUSS LAYOUTS SHOWN ON PLANS ARE SCHEMATIC ONLY. TRUSS MANUFACTURER <br />AND/OR ENGINEER SHALL BE RESPONSIBLE FOR THE DESIGN AND SPACING OF ALL <br />TRUSSES AND SHALL SUBMIT SHOP DRAWINGS TO THE BUILDER FOR APPROVAL. <br />3. TI-E WOOD TRUSS MANUFACTURER MUST PARTICIPATE IN A CODE APPROVED THIRD PARTY <br />QUALITY ASSURANCE PROGRAM SUCH AS THE TRUSS PLATE INSTITUTE'S "QUALITY CONTROL <br />INSPECTION PROGRAM" OR EQUIVALENT. <br />4. WOOD TRUSS MEMBERS AND CONNECTIONS SHALL BE DESIGNED FOR ALL LOADS SHOWN ON <br />THE CONTRACT DOCUMENTS INCLUDING: LIVE, DEAD, AND CONCENTRATED LOADS, PLUS <br />WIND LOADS. <br />5. REFER TO THE FLOOR PLAN AND OTHER STRUCTURAL DETAIL SHEETS FOR IMPORTANT <br />INFORMATION NOT SPECIFICALLY ADDRESSED BY THE TRUSS FRAMING LAYOUT <br />SUCH AS BEARING WALL HEIGHTS AND CEILING VAULT DETAILS. <br />6. WOOD TRUSS DESIGN SHOP DRAWINGS SHALL INCLUDE, BUT ARE NOT LIMITED TO, <br />THE FOLLOWING INFORMATION: <br />as SPAN LENGTH, OVERHANG AND SAVE DIMENSIONS, SLOPE AND SPACING OF <br />THE WOOD TRUSSES. <br />b-) ALL DESIGN LOADS AND THEIR POINTS OF APPLICATION, VALLEY AND CONVENTIONAL <br />FRAMING MUST BE CONSIDERED. <br />c.) ADJUSTMENTS TO ALLOWABLE VALUES. <br />d.) REACTIVATE FORCES AND THEIR LOCATIONS. <br />ea BEARING TYPE AND MINIMUM BEARING LENGTH. <br />0 DEFLECTIONS. <br />S.) METAL CONNECTOR PLATE TYPE, GAUGE, SIZE, AND LOCATION. <br />ha LUMBER SIZE, SPECIES, GRADE AND MOISTURE CONTENT. <br />1a LOCATION AND CONNECTION DESIGN OF REQUIRED CONTINUOUS LATERAL BRACING. <br />J.) NET UPLIFT LOADS BASED ON ACTUAL BUILDING DEAD LOAD. <br />k) WEB REINFORCEMENT DETAILS FOR GABLE END TRUSSES. <br />IJ VALLEY SETS FOR OVER -BUILD CONDITIONS. <br />1. LIMIT DEFLECTIONS FOR LIVE LOAD TO SPAN/360 (ROOF), SPAN/480 (FLOOR), AND <br />LIMIT TOTAL LOAD DEFLECTIONS TO SPAN/240 (ROOF), SPAN/360 (FLOOR) UNLESS <br />SPECIFICALLY NOTED OTHERWISE. <br />S. FIRE RETARDANT WOOD IS NOT ALLOWABLE FOR USE AS TRUSS CHORDS OR WEBS. <br />9 WOOD TRUSSES SHALL BE DESIGNED SO THAT MINIMAL HORIZONTAL REACTIONS <br />ARE IMPOSED ON THE SUPPORTING STRUCTURE UNDER VERTICAL LOADS. NO SLIP <br />CONNECTIONS ARE ALLOWED UNLESS OTHERWISE NOTED. CONTACT CONTRACTOR AS REQUIRED. <br />10. WOOD TRUSSES MUST BE CHECKED FOR WIND. WIND VELOCITY, DESIGN VELOCITY <br />PRESSURES, AND MEAN ROOF HEIGHT MUST ISE SHOWN ON THE SUBMITTED SHOP DRAWINGS. <br />II. CONTINUOUS BOTTOM CHORD LATERAL BRACING 18 REQUIRED AT A MINIMUM <br />SPACING OF 10' O.C. UNLESS NOTED OTHERWISE. BOTTOM CHORD BRACING IS <br />CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER END. OVERLAP <br />CONTINUOUS BRACING At LEAST ONE TRUSS SPACE. USE A MINIMUM OF 2 X 4 <br />(ROOF), 2X6 (FLOOR) GRADE MARKED LUMBER AT LEAST 10' LONG, WITH 2-16d <br />NAILS At INTERMEDIATE AND 3-16d NAILS AT END CONNECTIONS. <br />12. CROSS BRACING 18 REQUIRED AT MINIMUM 10' O.C. UNLESS NOTED OTHERWISE. LOCATE <br />CROSS BRACING AT OR NEAR THE BOTTOM CHORD BRACING. INSTALL CROSS BRACING AT <br />EAC -I END AND AT 20O.C. ALONG THE LENGTH OF T14E LATERAL BRACING. CROSS <br />BRACING IS ACCOMPLISHED BY ATTACHING DIAGONAL WEB BRACNG TO OPPOSITE SIDES <br />OF THE SAME GROUP OF SIMILAR WEB MEMBERS. SLOPE CROSS BRACING IN OPPOSITE <br />DIRECTIONS AT APPROXIMATELY 45 DEGREES FORMING A CROSS "X". USE A MINIMUM( OF <br />2X4 GRADE MARKED LUMBER WITH AT LEAST 3-16d NAILS AT EACH CONNECTION. <br />13. TRUSS ERECTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING OF TRUSS <br />SYSTEM DURING CONSTRUCTION. <br />14. HANDLING, INSTALLATION, AND BRACING OF WOOD TRUSSES SHALL BE IN ACCORDANCE <br />WITH "HUB-91", PUBLISHED BY THE TRUSS PLATE INSTITUTE. <br />15. ALL WOOD TRUSSES SHALL BE FASTENED TO THEIR SUPPORTS WITH APPROVED 14URRICANE <br />ANCHORS, RATED TO CARRY UPLIFT LOADS SPECIFIED BY TRU88 MANUFACTURER <br />16. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY SIMPSON <br />STRONG* -TIE, OR APPROVED EQUIVALENT MANUFACTURER ALL NAIL HOLES SHOULD <br />BE FILLED, OR AS PRESCRIBED BY T14E MANUFACTURER <br />11. TRUSSES ARE TO BE DESIGNED TO ALLOW FOR THE PROPER ROUTING OF A/C <br />DUCT WORK AND PLUMBING. CHASES SHALL NOT BE BLOCKED BY WOOD TRUSSES. <br />18. PILING OF PLYWOOD ON WOOD TRUSSER IS NOT ALLOWED. <br />19. INSTALLATION OF BROKEN, DAMAGED, WARPED, OR IMPROPERLY REPAIRED WOOD <br />TRUSSES IS NOT ALLOWED. <br />20. IMPROPER OR UNAUTHORIZED FIELD ALTERATIONS OF WOOD TRUSSES IS NOT ALLOWED. <br />21. GABLE ENDWALL TRUSSES 1'IUIST TRANSFER LATERAL LOADS TO THE SHEAR WALLS AND/OR <br />THE RDOF DIAPHRAGM. <br />22. WOOD TRUSSES THAT DO NOT MEET INTERIOR LOAD BEARING WALLS MUST BE SHIMMED. <br />DO NOT PULL WOOD TRUSSES DOWN TO INTERIOR BEARINGS. <br />23. SUBMITTAL$: ALL 15I,113MITTALS SHALL BEAR THE EMBOSSED SEAL OF A LICENSED STRUCTURAL <br />ENGINEER IN THE STATE OF FLORIDA AND SMALL BE SUBMITTED TO CONTRACTOR FOR <br />REVIEW PRIOR TO WOOD TRUSS FABRICATION. <br />as SUBMIT SEALED WOOD TRUSS DESIGN CALCULATIONS AND PROFILES FOR EACH TYPE OF <br />TRJS8 WITH PERMANENT BRIDGING REQUIREMENTS. <br />bJ SUBMIT WOOD TRUSS ERECTION PLAN, INCLUDING CONNECTION DETAILS AND UPLIFT <br />ANCHORS. <br />ca SUBMIT WOOD TRUSS TEMPORARY ERECTION BRACING PLAN. <br />des MAINTAIN COPY OF SUBMITTAL ON JOBSITE. <br />PROTECTION AGAINST TERMITES <br />R318J Termits Protactton. Termite protection shall be provided by registered temiticides, Including soil applied pesticides, batting <br />systems and pestlotdas applied to wood, or other approved methods of termite protection labeled for use as a prevenative treatment <br />to now construction. Sss Section 202, Registered termittctde. Upon completion of the application of the to protective treatment, a <br />Certlflcate of Compliance shall be Issued to the building department by the Ilcansed pest control company that contains the following <br />statement: trh@ building has received a complete treatment for the prevention of subterranean termites. Treatment is In accordance <br />with rules and laws established bg the Florida Department of Agriculture and Consume ServlcaA. <br />R318.1.1 If soil treatment is used for subterranean termite prevention, the initial chemical soil treatment Inside the foundation <br />perimeter shall be done after all excavation, badafilling and compaction Is completes <br />R318.12 If soil treatment is used for subterranean termits prevention, soil area disturbed after initial chemical soil treatment shall <br />be retreated with a chemical soil treatment, including spaces boxed or formed. <br />R318.13 If soil treatment is used for subterranean tormite prevention, space In concrete floors boxed out or formed for the <br />subsequent installation of plumbing traps, dralns or any other purpose shell be created b9 using plastic or metal permanently <br />placed forms of sufficient depth to eliminate any planned soil disturbance after Initial chemical soil treatment. <br />R318.1.4 If soil treatment Ie used for subterranean termite prevanion, chemically treated soil shall be protected with a minimum 6 <br />mil vapor retarder to protect against rainfall diluttor. If rainfall occurs before vapor retarder placement, retreatment is required. <br />Any worm, including placement of reinforcing steel, dons after d anlcal treatment until the core vte floor Is poured, shell be dons <br />in such manner ae to avoid penstratme or disturbing treated soli <br />R318.15 If soil treatment Is used for subterranean termite prevention, concrete overpour or mortar accumulated along the exterior <br />foundation perimeter shall be removed prior to exterior chemical soil treatment, to enhance vertical penetration of the chemicals. <br />R318.16 If soil treatment is used for subterranean termite prevention, do. Ica I soil treatmens shell also be applied under all <br />exterior concrete or grade within 1 foot (305 mm) of the primary structure stalmalhs. Also, a vertical chemical barrier shall be <br />applied promptly after construction is completed, including initial landscaping and Irrigation/sprinkler installation. Ang soil disturbed <br />after the chemical vertical barrier is applied shell be promptly retreated. <br />R318.11 If a registered temitiolde formulated and registered as a bait system is used for subterranean termite prevention, <br />Sections R318.0 through R310.1.6 do not applyt however, a slgned contract aesur►ng the installation, maintenance and monitoring <br />of the baiting systs i for a minimum of 5 years from the lsew of the Certificate of Occupanoy shell be provided to the building <br />official prior to the pouring of the slab, and the system must be Installed prior to final building approval. If the baiting system <br />directions for use require a monitoring phase prior to installation of the pesticide active ingredient, the Installation of the <br />monitoring phase components shell be deemed to constitute installation of the system. <br />R318.1.8 If a registered temlticide formulated and registered as a wood treatment Is used for subterranean termite prevention, <br />Sections 11019U through R318JA do not apply. Application of the wood treatment termlticide shall be as required b9 label <br />directions for use, and must be completed prior to final building approval. <br />R3182 Penetration. Protective sleeves around piping penetrating concrete slab -on -grads floors shall not be of celluloae-contalning <br />materials and, if soil treatment is used for subterranean termite protection, the sleeve shell have a maximum wall thickness of 0010 <br />inch (025 mm) and be sealed within the slab using non -corrosive clamping device to eliminate the amular space between pipe and <br />the sleava. No temiticides shell be applied melds the sleeve. <br />R3183 Cleaning. Calls and cavities In masonry units and air gaps between brick, storm or masonry verses and the structure shall be <br />cleared of all non-presevative treated or non -naturally durable wood, or other cellulose -containing material prior to concrate <br />Placement. <br />Exception: Inorganic material manufactured for closing cells in foundation concrete masonry unit construction or clean earth rill <br />placed in concrete masonry unit voids below slab level before termite treatment Is performed. <br />FaIDA Concrete bearing ledge,15rtoK stone or other veneer shall be supported b9 a concrete bearing ledge at least equal to the total <br />thickness of the brick store or other venoar which Is poured Integrally with the concrete foundation. No supplemental concrete <br />foundation pours which will create a hidden cold Joint shell be used without supplemental treatment in the foundation unless there is an <br />approved physlcal barrier. An approved phpical barrier shell also be Installed from below the wall sill plate or first block course <br />horizontally to embed in a mortar Joint. If masonry verse extends below grads, a termite protective treatment must be applied to the <br />cavky created between the veneer and the foundation, in lieu of a phyelcal barrier. <br />Exception: Vereer supported by a structural member escavol to the foundation stdawall In accordancom with ACI530/ASCE 5/TMS <br />402, provided at least a 6 Inch (152 mm) clear inspection space of the foundation sidewall exterior exist between the verse and <br />the top of any soil, sod, mulch or other organic landscaping component, deck apron, porch walk or ang other work Immediately <br />adjacent to or adjoining the structure. <br />R318J5 Protection against decay and term►tas. Condansate lines, IrrigatloWspriricler system rises for spray heads, and roof downspouts <br />shall discharge at least I foot (305 mm) away from the structure sidamall, whether b9 underground piping, tail sxtewlom or splash <br />blocks. Gutters with downspouts are required on all buildings with saves of Isms than 6 Inches (02 mm) horizontal proJsotion except <br />for gable and rakes or on a roof above another roof. <br />R318b Preparation of building *Ito and removal of debris. <br />R3186.1 All building sites shall be graded to provide drainage under all portions of the building not occupied by basements. <br />R31862 The foundation and the area encompassed within 1 foot (305 mm) therein shall have all vegetation, stumps, dead roots, <br />cardboard, trash and foreign material removed and the fill material shall be free of vegetation and foreign material. The fill shell be <br />compacted to assure adequate support of the foundation. <br />R31663 Artier all work is completed, loose wood and debris shall be completely removed from under the building and within I foot <br />(305 mm) thereof. All wood forms and supports shall be completely removed This Includes, but Is not limited to: wooden grade <br />stales, forms, contraction spacers, tub trap boxes, plumbing supports, bracing, shoring, fors or other cellulose -containing <br />material placed in any location where such materials are not clearly visible and readlly removable prior to completion of the work <br />Wood shall not be stored in contact with the ground under any building. <br />TYPICAL NAILING% SCHEDULE <br />Ledger strip <br />16d common <br />3 at each joist <br />Sol@ plate to joist or <br />16d common <br />I6' Of- <br />blocifti, face nail <br />Top of sole plate to stud, <br />16d common <br />2 <br />and nailed <br />Stud to sob plate, toe nail <br />Sd common <br />4 <br />Doubled studs, face nail <br />Wd common <br />24' OC. <br />Dom6led top plates, face <br />10d common <br />16' along each <br />tall <br />edge <br />Conthim Hieader to <br />8d common <br />3 <br />stud, toe nail <br />DO sheathing or less to <br />Sd common <br />2 <br />each bearing, face nail <br />Over NO sheathing to <br />ad common <br />3 <br />each bearing, face nail <br />BuIld-Lp comer studs <br />*d common <br />24' OC. <br />Build-up grlders and <br />20d common <br />32' O:C. at top <br />beams IV to three mmembim <br />and bottom and <br />staggered 2 ends <br />at each <br />splice <br />IA' Gypsum Sheathing <br />11 ga 14,2' <br />41O.C, at edges <br />1/16' head <br />8' = at other bear . <br />5/8" Gypsum sheathing <br />II ga 1-3/4' <br />410C. at edges <br />1/I6' head <br />8' o,c, at other bear . <br />Gypsum Wallboard <br />1/1' <br />1-3W dWII nail <br />11O.C. on callings <br />8"OC. on walls <br />5/8' <br />1-1/2' drywall nail <br />11OC. an ceilings <br />$Via on walls <br />Hardboard Lap Siding, <br />Sd corrosion resistant <br />16, OC. at top <br />Direct to Studs <br />with minimum shank <br />and bottom edges <br />dia. of 00M Irah <br />and minimum head <br />dia. of 0240 kich <br />Hardboard Lap Siding, <br />10d corrosion resistant <br />Ib" OC. at top <br />over sheathing <br />with minimum shank <br />and bottom edges <br />dia. of 00990 Inch <br />and minimum head <br />dia. of 0240 Inch <br />Hardboard Panel sldkmg, <br />bd corrosion resistant <br />6:r,' O.C. at edges <br />Direct to Suds <br />with minlmmm shank <br />121 OC. at <br />d1a. of 00NO inch <br />hartilediate <br />and minimum head <br />supports <br />dia. of 0225 inch <br />Hardboard Panel siding, <br />Sd corrosion resistant <br />6M' OC at edges <br />Over to Slwthing <br />minimum <br />with shank <br />121 OC. at <br />dia. of 00WO inch <br />Intermediate <br />and mtnWw head <br />supports <br />dia. of 0225 Inch <br />ALL MANUFACTURED PRODUCTS SUCH AS ROOFING, WINDOWS, DOORS, ETC. ARE SHOWN HEREIN FOR <br />ILLUSTRATION PURPOSES ONLY. THE INFORMATION SHOWN IS THE RESPONSIBILITY OF THE MANUFACTURER THE <br />MANUFACTURER IS RESPONSIBLE FOR THE VALIDITY OF THE COMPONENTS PROVIDED. ATTACHMENT <br />INFORMATION GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN. CONTRACTOR AS PROJECT COORDINATOR <br />814ALL BE RESPONSIBLE FOR INSURING THAT THE APPROPRIATE PRODUCT/COMPONENT IS USED AND THAT IT <br />HAS BEEN INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH THAT IT WILL WITHSTAND THE COMPONENTS <br />,AND CLADDING PRESSURES REQUIRED BY THE SEALED PLANS. <br />PRE -CAST AND PRE -STRESSED CONCRETE COMPONENTS SHALL BE USED AND INSTALLED PER MANUFACTURER'S <br />SPECIFICATIONS. PRE -CAST LINTELS HAVE BEEN REVIEWED AND PLACED BASED ON DESIGN ALLOWABLE LOAD <br />INFORMATION PROVIDED BY CAST CRETE. THEREFORE, CAST CRETE IS A DELEGATED ENGINEER FOR THIS PROJECT. <br />ENGINEER OF RECORD MUST APPROVE IN WRITING ANY CHANGE IN LINTEL MANUFACTURER ALL OTHER STRUCTURAL <br />PRE -CAST COMPONENT MANUFACTURERS MUST SUBMIT DESIGN LOAD INFORMATION TO ENGINEER OF RECORD FOR <br />APPROVAL. ENGINEER OF RECORD RESERVES THE RIGHT TO MAKE ANY CHANGES ,AFTER SUCH INFORMATION HAS <br />BEEN PROVIDED FOR REVIEW. CONTRACTOR AS PROJECT COORDINATOR SHALL BE RESPONSIBLE FOR INSURING <br />INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN A TIMELY MANNER WHEN <br />AVAILABLE. <br />UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER INDICATING ANY CHANGE IN STRAPPING OR <br />SUPPORT BASED ON THAT REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW IS SUBJECT TO <br />MODIFICATION BASED ON REVIEW LETTER <br />EXTERIOR CEMENTITIOUS FINISH <br />CEMENTITIOUS FINISH OVER FRAME TO BE A MINIMUM 1/8" IN THICKNESS CEMENTITIOUS FINISH OVER CMU TO BE A <br />MINIMUM 5/8" IN THICKNESS TO MEET ASTM C926 <br />CONNECTOR PRODUCT APPROV&5 <br />APPICATION <br />SIMPSM OMWTOR <br />FL APPROVAL No. <br />CZ, EGG, PG, EPG <br />FL 10&60 <br />GAP5 AND BA5E5 <br />ABU <br />FL 10&4ri <br />HU, HUG <br />FL 10655 <br />H6T, MBHA <br />FL 10866 <br />HD, HDQB, HHDQ <br />FL 10441 <br />GONGRETE / MASONRY <br />GONNEGTOR5 <br />DETAL, F6TR, HETA, HHETA, HM, <br />HT5M, H6AM, H6UM, L6UM, LTA, META, <br />FL 11473 <br />M5TAM, M5TGM, MT5M <br />H6A10, L&T, M6T, M5TG, V6T <br />FL 11410 <br />HTT, LTT <br />FL 114g6 <br />LRU, L5W, 1_511,1, THA <br />FL 10441 <br />HHU5, WWI-, HSUR, HU, HUG, 11.6 T, LU, <br />11U5, MU,5UL, BUR, U <br />FL 10531 / FL 10655 <br />H6U, H6UQ, Ha6, HH61J, HHUS, RXQ, <br />14U5, LGU, LU5, M6U, M5GPT, THA, TH65, <br />FL 10531 / FL 11468 <br />HAN6ER5 <br />W50, TH6H, THJ U <br />B, BA, H6, LBV <br />FL 10661 <br />E6, 66, 6L5, 6L5T, 6LT, 61-TV, H66, H6L5, <br />H6LT, H6LTV, HHB, HHBD, HIT, HK HHI, <br />HM, IT5,I7 ME6, MIT, MSG, H, HI, HNR <br />FL 10667 <br />WNPU, HP, UPI, WPU, <br />A, Fr,, 6A, H, H6A, HH, L, L5, LPT, Z <br />FL 10446 <br />STRAPS AND TIES <br />05P, FTA, H, H6T, HT5, LFTA, LT5, MT5, RSP <br />R5T, 5P, 5PH, 55P <br />FL 10456 <br />GM5T, 05, FHA, H5T, 1_5TA, L5TI, M5T, <br />M5TA, M5TG, M5TI, 5T <br />FL 108,52 <br />WIND LOADS <br />Florida Building Code <br />5th Edition (2014) <br />AND ASCE 7-10 METHODS <br />ULTIMATE WIND SPEED (MPH) <br />150 <br />EXPOSURE CATEGORY <br />C <br />BUILDING RISK CATEGORY <br />III <br />ROOF SLOPE <br />Roof > 7 to 27 degrees <br />INTERNAL PRESSURE <br />COEFFICIENT <br />ENCLOSED 0.18 <br />TOPOGRAPHICAL FACTOR <br />FLAT 1.0 <br />MAXIMUM BUILDING HEIGHT <br />30 <br />FT <br />3�2 <br />312�3 <br />13 <br />I I <br />I <br />a <br />1 1 <br />rCDr__ i r� <br />r� <br />a <br />a <br />3 <br />�- -I- <br />2 <br />-1- <br />3 3 <br />--4 <br />2 <br />3 <br />W G� I S <br />I \ <br />O O <br />WIDTH EDGE <br />STRIPSPS (a) <br />10 <br />FT <br />OPENING <br />PROTECTION REQUIRED <br />COMPONENT & CLADDING DESIGN PRESSURE (PSF) <br />ZONE 1 <br />ZONE 2 <br />ZONE <br />3 <br />ZONE 4 <br />ZONE 5 <br />Area of C&C (SF) <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />10 <br />32.6 <br />-51.8 <br />32.6 <br />-90.3 <br />32.6 <br />-133.6 <br />56.7 <br />-61.5 <br />56.7 <br />-75.9 <br />20 <br />29.8 <br />-50.4 <br />29.8 <br />-83.0 <br />29.8 <br />-124.9 <br />54.2 <br />-58.9 <br />54.2 <br />-70.7 <br />50 <br />25.9 <br />-48.4 <br />25.9 <br />-73.5 <br />25.9 <br />-113.4 <br />50.7 <br />-55.6 <br />50.7 <br />-64.0 <br />100 <br />23.1 <br />-47.0 <br />23.1 <br />-66.2 <br />23.1 <br />-104.7 <br />48.2 <br />-52.9 <br />48.2 <br />-58.9 <br />WINDOWS AND DOORS DESIGN PRESSURE (PSF) BASED ON Vasd <br />ZONE 1 <br />ZONE 2 <br />ZONE 3 <br />ZONE 4 <br />ZONES <br />Area (SF) or description <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />Positive <br />Negative <br />10 <br />19.6 <br />-31.1 <br />19.6 <br />-54.2 <br />19.6 <br />-80.1 <br />34.0 <br />-36.9 <br />34.0 <br />-45.5 <br />20 <br />17.9 <br />-30.2 <br />17.9 <br />-49.8 <br />17.9 <br />-74.9 <br />32.5 <br />-35.4 <br />32.5 <br />-42.4 <br />50 <br />16.0 <br />-29.1 <br />16.0 <br />-44.1 <br />16.0 <br />-68.0 <br />30.4 <br />-33.3 <br />30.4 <br />-38.4 <br />100 <br />16.0 <br />-28.2 <br />16.0 <br />-39.7 <br />16.0 <br />-62.8 <br />28.9 <br />-31.8 <br />28.9 <br />�ZW <br />Zak <br />�Zs <br />z <br />z <br />�m� <br />O <br />`08 <br />U) <br />g < <br />W <br />>LLJ <br />cr <br />Q <br />x� <br />iU.1 <br />; a <br />r <br />O <br />> <br />CZ <br />CC <br />0 <br />O <br />0 <br />C: <br />Cz <br />LL <br />W''^^� <br />p <br />_ <br />CZ <br />> <br />Q. <br />(n fn IV <br />BSB <br />DESIGN <br />www.bsbdesign.com <br />100 Main St. Suite 209 <br />Safety Harbor, Florida 34695 <br />813 265 4808 <br />JOB NO: AM PROJ MGR: LCC <br />DRAWN: LCC CHECKED: <br />STRUCTURAL NOTES <br />AND DETAILS <br />SD1 <br />