EGRESS: <br />MINIMUM SIZE. <br />EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A <br />, MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. <br />EXCEPTION: <br />1. ALL GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET <br />CLEAR OPENING OF 5 SQ FT. <br />MAXIMUM HEIGHT FROM FLOOR: <br />EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE <br />BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES <br />MEASURED FROM THE FLOOR. <br />2. OPERATIONAL CONSTRAINTS: <br />EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE <br />OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE <br />OF KEYS OR TOOLS. BARS, GRILLES, GRATES OR SIMILAR DEVICES <br />ARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE AND <br />RESCUE OPENINGS PROVIDED THE MINIMUM NET CLEAR OPENING <br />SIZE COMPLIES WITH SECTION 1030.4 AND SUCH DEVICES SHALL <br />BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THE <br />USE OF A KEY, TOOL OR FORCE GREATER THAN THAT WHICH IS <br />REQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUE <br />OPENING. <br />3. FALL PROTECTION: <br />WHERE THE OPENING OF THE SILL PORTION OF AN OPERABLE <br />WINDOW IS LOCATED MORE THAN 72 INCHES (1829 MM) ABOVE <br />THE FINISHED GRADE OR OTHER SURFACE BELOW, THE LOWEST <br />PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AT A <br />HEIGHT NOT LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHED <br />FLOOR SURFACE OF THE ROOM IN WHICH THE WINDOW IS <br />LOCATED. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24 <br />INCHES (610 MM) SHALL BE FIXED OR HAVE OPENINGS THROUGH <br />WHICH A 4-INCH (102 MM) DIAMETER SPHERE CANNOT PASS. <br />EXCEPTION: OPENINGS THAT ARE PROVIDED WITH WINDOW <br />GUARDS THAT COMPLY WITH ASTM F 2006 OR F 2090. <br />HAZARDOUS LOCATIONS: <br />1. GLAZING IN DOORS: GLAZING IN ALL FIXED AND OPERABLE PANELS <br />OF SWINGING, SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED A <br />HAZARDOUS LOCATION. <br />EXCEPTIONS: <br />1. DECORATIVE GLAZING <br />2. WHEN THERE IS AN INTERVENING WALL OR OTHER <br />PERMANENT BARRIER BETWEEN THE DOOR AND THE <br />GLAZING. <br />3. GLAZING IN WALLS ON THE LATCH SIDE OF AND <br />PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED <br />POSITION. <br />4. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR <br />STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THIS <br />APPLICATION SHALL COMPLY WITH SECTION R308.4.3. <br />5. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO <br />DOORS. <br />' 2. GLAZING IN WINDOWS: <br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS <br />ALL OF THE FOLLOWING CONDITIONS: <br />1. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 <br />SQUARE FEET. <br />2. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />3. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />4. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 <br />MM) HORIZONTALLY OF THE GLAZING. <br />3. GLAZING AND WET SURFACES: <br />GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING <br />SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY <br />WALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. THIS <br />SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. <br />EXCEPTION: GLAZING THAT IS MORE THAN 60" (1,524 mm), MEASURED <br />HORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER'S EDGE OF A <br />BATHTUB, HOT TUB, SPA, WHIRLPOOL, OR SWIMMING POOL OR FROM THE <br />EDGE OF A SHOWER, SAUNA, OR STEAM ROOM. <br />4. GLAZING ADJACENT TO THE BOTTOM OF A STAIR LANDING: <br />GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY <br />WHERE THE GLAZING IS LESS THAN 36" ABOVE THE LANDING AND WITHIN 60" <br />HORIZONTALLY OF THE BOTTOM TREAD SHALL BE CONSIDERED A <br />HAZARDOUS LOCATION. <br />R309.1 FLOOR SURFACE: <br />GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE <br />MATERIAL. <br />THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER <br />VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS <br />TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. <br />R302.9 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR WALL <br />AND CEILING FINISHES <br />FLAME SPREAD AND SMOKE DEVELOPED INDEXES FOR WALL AND <br />CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1 <br />THROUGH R302.9.4. <br />R302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR <br />INSULATION <br />FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL <br />BE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5. <br />ITP <br />GENERAL CONSTRUCTION NOTES: <br />TREADS AND RISERS: <br />THE MAXIMUM RISER HEIGHT SHALL BE 7.75" AND THE MINIMUM <br />TREAD DEPTH SHALL BE 10". THE TREAD DEPTH SHALL BE <br />MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF <br />THE FOREMOST PROJECTION OF THE ADJACENT TREADS AND AT A <br />RIGHT ANGLE TO THE TREADS LEADING EDGE. THE MINIMUM <br />WINDER TREAD DEPTH AT THE WALK LINE SHALL BE 10", AND THE <br />MINIMUM WINDER TREAD DEPTH SHALL BE 6". NOSING SHALL <br />NOT BE LESS THAN 3/4" BUT NOT MORE THAN 1 1/4". A NOSING <br />SHALL NOT BE REQUIRED WHERE THE TREAD DEPTH IS 11". <br />HANDRAILS: <br />HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH <br />CONTINUOUS RUN OF TREADS OR FLIGHTS OF 4 OR MORE RISERS. <br />HANDRAIL HEIGHT: <br />HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, OR <br />FINISH SURFACE OF RAMP SLOPE SHALL BE UNIFORM, NOT LESS <br />THAN 34" AND NOT MORE THAN 38". <br />HANDRAIL GRASPABILITY: <br />HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE AN <br />OUTSIDE DIAMETER OF AT LEAST 1.25" AND NOT GREATER THAN <br />2" OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THE <br />HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER <br />DIMENSION OF AT LEAST 4" AND NOT GREATER THAN 6.25" WITH A <br />MAXIMUM CROSS-SECTION DIMENSION OF 2.25". EDGES SHALL <br />HAVE A MINIMUM RADIUS OF 0.01". <br />HANDRAIL CONTINUITY: <br />HANDRAIL -GRIPPING SURFACES SHALL BE CONTINUOUS, <br />WITHOUT INTERRUPTION BY NEWEL POSTS OR OTHER <br />OBSTRUCTIONS. <br />EXCEPTIONS: <br />LHANDRAILS WITHIN DWELLING UNITS ARE PERMITTED TO <br />BE INTERRUPTED BY A NEWEL POST AT A STAIR OR RAMP <br />LANDING. <br />2. WITHIN A DWELLING UNIT, THE USE OF A VOLUTE, TURNOUT <br />OR STARTING EASING IS ALLOWED ON THE LOWEST TREAD. <br />3. HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THE <br />BOTTOM SURFACE OF THE HANDRAIL SHALL NOT BE <br />CONSIDERED OBSTRUCTIONS TO GRASPABILITY, PROVIDED <br />THAT THE FOLLOWING CONDITIONS ARE MET: <br />3.1. THEY DO NOT PROJECT HORIZ BEYOND THE SIDES OF THE <br />HANDRAIL WITHIN 1'/z" OF THE BOTTOM OF THE HANDRAIL <br />AND PROVIDED THAT, FOR EACH 1/2" OF ADDITIONAL <br />HANDRAIL PERIMETER DIMENSION ABOVE 4", THE VERTICAL <br />CLEARANCE DIMENSION OF V/2" CAN BE REDUCED BY 1/8". <br />3.2. THEY HAVE EDGES WITH A RADIUS OF NOT LESS THAN .01". <br />3.3. THEY OBSTRUCT NOT IN EXCESS OF 20 PERCENT OF THE <br />HANDRAIL LENGTH. <br />HANDRAIL CLEARANCE: <br />CLEAR SPACE BETWEEN A HANDRAIL AND A WALL OR OTHER <br />SURFACE SHALL BE A MINIMUM OF 1.5". A HANDRAIL AND A WALL <br />OR OTHER SURFACE ADJACENT TO THE HANDRAIL SHALL BE FREE <br />OF ANY SHARP OR ABRASIVE ELEMENTS. <br />GUARDS: <br />SHALL BE LOCATED ALONG OPEN -SIDED WALKING SURFACES, <br />PLATFORMS, STAIRWAYS, RAMPS AND LANDINGS THAT ARE <br />LOCATED MORE THAN 30" MEASURED VERTICALLY TO THE FLOOR <br />OR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TO <br />THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE <br />CONSIDERED AS A GUARD. <br />OPENING LIMITATIONS: <br />REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE <br />WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH <br />ALLOW THE PASSAGE OF A 4" SPHERE. <br />SCREEN PORCHES: <br />PORCHES AND DECKS WHICH ARE ENCLOSED WITH INSECT <br />SCREENING SHALL BE PROVIDED WITH GUARDS WHERE THE <br />WALKING SURFACE IS LOCATED MORE THAN 30" ABOVE THE <br />FLOOR OR GRADE BELOW. <br />FIRE PROTECTION: <br />FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL VERTICAL <br />AND HORIZONTAL CONCEALED DRAFT OPENINGS. <br />ASPHALT SHINGLES (IF APPLICABLE) : <br />1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALT <br />SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH <br />SECTION R905.2.6 AND R905.2.6.1. <br />R506.2.3 VAPOR RETARDER: <br />A 6-MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITH <br />JOINTS LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BE <br />PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE <br />COURSE OR THE PREPARED SUBGRADE WHERE NO BASE <br />COURSE EXISTS. <br />EXCEPTIONS <br />1. GARAGES, UTILITY BUILDINGS AND OTHER UNHEATED <br />ACCESSORY STRUCTURES. <br />2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OF <br />LESS THAN 70 SQUARE FEET (6.5 M2) AND CARPORTS. <br />3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOT <br />LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. <br />4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ON <br />LOCAL SITE CONDITIONS. <br />DRAFTSTOPPING: <br />IN COMBUSTABLE CONSTRUCTION WHERE THERE IS USABLE <br />SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A <br />FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED <br />SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT <br />EXCEED 1,000 SQUARE FEET. DRAFTSOPPING SHALL DIVIDE THE <br />THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. <br />WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE <br />ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING <br />SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE <br />FOLLOWING CIRCUMSTANCES: <br />1. CEILING IS SUSPENDED. <br />2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYP OPEN -WEB <br />PERFORATED MEMBERS. <br />1. MATERIALS: <br />DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2" <br />GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANELS OR OTHER <br />APPROVED MATERIALS ADEQUATELY SUPPORTED. <br />DRAFTSTOPPING SHALL BE INSTALLED PARALLELL TO THE <br />FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY <br />THE BUILDING OFFICIAL. <br />SEPARATION FROM GARAGE: <br />PER SECTION R302.5, R302.6, OPENING PROTECTION <br />1. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM <br />USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. <br />OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE <br />EQUIPPED WITH SOLID OR HONYCOMB CORE STEEL AND NOT LESS <br />THAN 1 3/8", 20 MINUTE RATED, WITH SELF CLOSER. <br />2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND <br />ITS ATTIC AREA BY NOT LESS TITAN 1/2" GYPSUM BOARD APPLIED <br />TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS <br />ABOVE BY NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD OR <br />EQUIVALENT. <br />CEILING CONSTRUCTION: <br />1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND <br />ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH (12.7 mm) GYPSUM <br />BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH <br />HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE <br />ROOMS ABOVE BY NOT LESS THAN 5/8 INCH (15.9 mm) TYPE "X" <br />GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A <br />FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE <br />SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2 <br />INCH (12.7 mm) GYPSUM BOARD OR EQUIVALENT. <br />EXTERIOR FINISHES: <br />1. CEMENT PLASTER FINISH OVER MASONRY SHALL BE 5/8" THICK <br />TEXTURED PER COMMUNITY STANDARDS. <br />2. CEMENT PLASTER FINISH OVER WOOD SUBSTRATE SHALL BE 7/8" <br />THICK (3) COAT STUCCO OVER (2) LAYERS OF WATER RESISTANT <br />BARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH <br />EDITION (2017) RESIDENTIAL, R703 AND ASTM C926. TEXTURE PER <br />COMMUNITY <br />FLASHING: <br />1. FLASHING SHALL BE INSTALLED AT WALL AND ROOF <br />INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, <br />AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND <br />ROOF OPENINGS. <br />2. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER <br />INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED <br />MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. <br />THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR <br />WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS <br />SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: <br />3. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT <br />EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE <br />SURFACE OF THE EXTERIOR WALL FINISH OR TO THE <br />WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. <br />FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE <br />INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />• THE FENESTRATION MANUFACTURER'S INSTALLATION AND <br />FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT <br />ADDRESSED IN THE FENESTRATION MANUFACTURERS <br />INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING <br />MANUFACTURERS INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING <br />SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND <br />DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED <br />IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF <br />THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE <br />BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION <br />AT THE HEAD AND SIDES. <br />• IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />• IN ACCORDANCE WITH FMA/AAMA 100, FMAIAAMA 200. FMA/WDMA <br />250, OR FMAIAAMAIWDMA 300 <br />WINDOW INSTALLATION: <br />1. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE <br />WITH THE MANUFACTURERS WRITTEN INSTALLATION <br />INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE <br />PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />FLOOD ZONE REQUIREMENTS: <br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE <br />FLOOR ELEVATION. <br />CHIMNEY HEIGHT REQUIREMENTS: <br />1. WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLED <br />THE CHIMNEY MUST EXTEND Y-0" PAST THE HIGHER POINT WHERE <br />IT EXTENDS THROUGH THE ROOF AND MUST BE T-0" HIGHER THAN <br />THE ROOF OR RIDGE THAT IS 10'-0" AWAY OR CLOSER. <br />TUB AND SHOWER AREAS: <br />1. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO <br />GREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1288, <br />C1325, OR C1178 AND INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER RECOMMENDATIONS SHALL BE USED AS <br />BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL <br />PANELS IN SHOWER AREAS. <br />MECHANICAL AND HVAC: <br />1. ENERGY CALCULATIONS FOR HEATING AND COOLING <br />CAPACITIES SHALL BE FURNISHED BY THE GENERAL <br />CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THE <br />TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR <br />INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT <br />REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, <br />OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE <br />APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR <br />REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762 <br />mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE PROVIDED IN <br />FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR <br />CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL <br />BE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OR <br />OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO <br />THE GARAGE. <br />4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL <br />SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 mm) ABOVE <br />THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING <br />APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN <br />PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL <br />OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN <br />PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS <br />M1411.3. <br />EXHAUST FANS AND VENTING: <br />1. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY <br />MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE <br />OUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, <br />SOFFIT, RIDGE VENT OR CRAWL SPACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL <br />NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER <br />DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE <br />OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS <br />SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER <br />AREAS INSIDE THE BUILDING. <br />3. DUCT LENGTH: THE MAXIMUM LENGTH OF A CLOTHES: DRYER <br />EXHAUST DUCT SHALL NOT EXCEED 35 FEET. THE DRYER LOCATION <br />TO THE WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF <br />THE DUCT SHALL BE REDUCED 2.5 FEET (762 mm) FOR EACH 45 <br />DEGREE (0.79 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE <br />(1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT <br />DOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A <br />CLOTHES DRYER BOOSTER FAN IS INSTALLED AND LISTED AND <br />LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THE <br />EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE <br />PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE A <br />CLOTHES DRYER BOOSTER FAN IS INSTALLED AND NOT READILY <br />ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER IS LOCATED, A <br />PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO <br />WHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL <br />BEAR THE WORDS "THIS DRYER EXHAUST SYSTEM IS. EQUIPPED <br />WITH A REMOTELY LOCATED BOOSTER FAN." <br />4. PROVIDE LOUVER DEVICES AT INTAKE AND <br />EXHAUST LOCATIONS IN ACCORDANCE WITH <br />AMCA STANDARD 550 IN FBC. <br />ATTENTION GENERAL CONTRACTOR / BUILDER: ISSUANCE OF <br />PLANS FROM THIS OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, <br />AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO <br />COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF <br />ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE <br />BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE <br />DRAFTER'S OFFICE FOR CORRECTION BEFORE COMMENCEMENT OF <br />ANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS OR <br />CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT <br />ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED <br />SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS <br />ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN <br />THE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELD <br />RESPONSIBLE. <br />FOUNDATION INSPECTION NOTES: <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF <br />THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTOR'S <br />USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A <br />STRING STRETCHED FROM MARKER TO MARKER TO VERIFY <br />REQUIRED SETBACKS. <br />FRAMING INSPECTION NOTES: <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH INS <br />MUST BE COMPLETE, INSPECTED, AND APPROVED BEFORE <br />REQUESTING THE FRAMING INSPECTION (FBC 110.6) <br />JUN 0 8 2020 <br />�0\ 111111 /j/G. <br />��� <br />VNo,"arF -�® <br />W <br />W <br />Luz0= <br />o >. F- <br />>o ¢o <br />LLI C, l- <br />cnUWw <br />Q Z) W <br />J In W W <br />!r Ir lY <br />06ZOO <br />W <br />Z <br />Lu -� Q <br />_3cno00 <br />Z) Z LL cn <br />�F--QZO <br />g <br />rt- <br />Qo <br />O <br />H <br />0 <br />r� <br />V <br />o <br />(n <br />m <br />W <br />kq <br />lono <br />® <br />Z <br />0 <br />w <br />w <br />ME=" <br />w <br />Z <br />w <br />r(L <br />v) <br />me, <br />0 <br />w <br />.w <br />Z <br />O <br />r <br />lx <br />U) <br />W <br />0 <br />c <br />Z <br />O <br />uj <br />u, <br />4 <br />Z <br />aaaaa <br />i <br />i <br />i <br />i <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS ! <br />PLAN # 6102 <br />RELEASED: S/14/20 <br />SHEET i <br />CS2 <br />z <br />_u <br />:n <br />z <br />D <br />z <br />A <br />2 <br />D <br />z <br />z <br />z <br />Q <br />r <br />D <br />T <br />D <br />i <br />z <br />Q <br />z <br />n <br />J <br />D <br />0 <br />D <br />r <br />i <br />r <br />L <br />n <br />